• Title/Summary/Keyword: 역류 현상

Search Result 84, Processing Time 0.028 seconds

Development of A System Optimum Traffic Control Strategy with Cell Transmission Model (Cell Transmission 이론에 근거한 시스템최적 신호시간산정)

  • 이광훈;신성일
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.5
    • /
    • pp.193-206
    • /
    • 2002
  • A signal optimization model is proposed by applying the Cell-Transmission Model(CTM) as an embedded traffic flow model to estimate a system-optimal signal timing plan in a transportation network composed of signalized intersections. Beyond the existing signal-optimization models, the CTM provides appropriate theoretical and practical backgrounds to simulate oversaturation phenomena such as shockwave, queue length, and spillback. The model is formulated on the Mixed-Integer Programming(MIP) theory. The proposed model implies a system-optimal in a sense that traffic demand and signal system cooperate to minimize the traffic network cost: the demand departing from origins through route choice behavior until arriving at destinations and the signal system by calculating optimal signal timings considering the movement of these demand. The potential of model's practical application is demonstrated through a comparison study of two signal control strategies: optimal and fixed signal controls.

A study on the construction of rainfall inundation measuring devices for the application of urban flood monitoring technology (도시침수 모니터링 기술 적용을 위한 강우-침수계측장치 구축에 관한 연구)

  • Kyung-Su Choo;Hyeon Ji Lee;Byung-Sik Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.258-258
    • /
    • 2023
  • 도시침수는 하천홍수와는 달리 짧은 시간에 발생하며 저지대 우수 유입, 배수관로 용량 부족등으로 인해 발생한다. 추가적 원인으로 국지성 집중호우가 있으며 짧은 시간에 많은 비가 집중적으로 내리는 현상을 의미한다. 한두 시간 혹은 몇 분 동안의 짧은 시간에 좁은 지역에서 발생하는특성 때문에 발생 시간, 지점, 강우량에 대한 정확한 예측이 어려워 도심지의 저지대가 침수되는등 예상치 못하는 침수피해가 자주 발생한다. 강우량별 피해 범위를 보면 시간당 30~40mm 정도에서 하수관이 역류하고, 시간당 50mm 강우량에서 지하실이나 지하상가와 같은 지하공간에서 침수피해가 발생할 수 있으며, 시간당 100mm 이상의 강우에서는 대규모 재해가 발생할 우려가 높아진다. 도시침수 피해를 줄이기 위해 지자체에서는 CCTV를 운영하여 위험을 감시하고 있지만다수의 인력과 환경에 따라 영상 확인의 한계가 있다. 그러나 침수센서는 침수 정도를 수치로 표현하여 데이터를 확보함과 동시에 다수의 지역을 모니터링하는데 유용하다. 또한 주변 환경에 상관없이 계측된 자료를 모니터링 할 수 있다. 기존 센서를 설계할 때는 도시 미관을 해치는 경우가있었으나 본 연구에서는 도심지의 여건에 맞추어 인도용, 차도용, 공원용의 용도에 맞는 센서를구축하여 미관을 해치지 않으면서 기존의 지형을 활용하고자 하였다. 이 후 구축된 센서를 이용하여 리빙랩 개념의 테스트베드를 통해 다양한 도시침수의 원인이 되는 조건을 검토하여 실증 실험을 진행할 예정이다.

  • PDF

LES for Turbulent Duct Flow with Surface Mass Injection (질량분사가 있는 덕트 난류유동의 LES 해석)

  • Kim, Bo-Hoon;Na, Yang;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.3
    • /
    • pp.232-241
    • /
    • 2011
  • The hybrid rocket shows interesting characteristics of complicated mixing layer developed by the interaction between turbulent oxidizer flow and injected surface mass flow from fuel vaporization. In this study, the compressible LES was conducted to explore the physical phenomena of surface oscillatory flow induced by the flow interferences in a duct domain. From the numerical results, the wall injection generates the stronger streamwise vorticites and the negative components of axial velocity accompanied with the azimuthal vorticity near the surface. And the vortex shedding with a certain time scale was found to be developed by hydrodynamic instability in the mixing layer. The pressure fluctuations in this calculation exhibit a peculiar peak at a specific angular frequency($\omega$=8.8) representing intrinsic oscillation due to the injection.

Development of Storm Sewer Numerical Model for Simulation of Coastal Urban Inundation due to Storm Surge and Rainfall (폭풍해일과 강우에 의한 해안 도시 범람 수치모의를 위한 우수관망 수치모형의 개발)

  • Yoon, Sung Bum;Lee, Jaehwang;Kim, Gun Hyeong;Song, Ji Hoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.5
    • /
    • pp.292-299
    • /
    • 2014
  • Since most of the researches on the coastal inundation due to typhoons have considered only storm surges, an additional inundation due to rainfall has been neglected. In general, typhoons are natural disasters being accompanied by the rainfall. Thus, it is essential to consider the effect of rainfall in the numerical simulation of coastal inundation due to storm surges. Because the rainwater is discharged to the sea through the storm sewer system, it should be included in the numerical simulation of storm surges to obtain reasonable results. In this study an algorithm that can deal with the effects of rainfall and sewer system is developed and combined with a conventional storm surge numerical model. To test the present numerical model various numerical simulations are conducted using the simplified topography for the cases including the inundation due to rainfall, the drainage of rainwater, the backflow of sea water, and the increase of sea water level due to drainage of rainwater. As a result, it is confirmed that the basic performance of the present model is satisfactory for various flow situations.

A Study on the Cold Flow Characteristics of a Flue Gas Recirculation Burner with Both Outlets Opening (양쪽 출구가 트인 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.7-12
    • /
    • 2018
  • Thermal NOx is generated in a high temperature environment in a combustion facilities. Exhaust gas recirculation method is widely used among various methods for reducing nitrogen oxides in combustion devices. In the present study, the computational fluid dynamic analysis was accomplished to elucidate the cold flow characteristics in the flue gas recirculation burner with both outlets opening. Because the reciculation pipes is installed toward the tangential direction, the swirling flow is formulated in the burner and the phenomenon of the reverse flow creation is detected at the center area of circular burner. We are confirmed that this is the similar trend with the burner with one side outlet closed. From the present study, it was seen that the recirculated inflow from both recirculated burner outlets increased by about 5% compared to the burner with one side outlet opening. At the outlet located at the exhaust gas recirculation pipe inlet(gas exit 1), the inlet flow was formed in the entire region. At the opposite outlet(gas exit 2), the total flow was discharged, but the center part of the burner was observed to have a reverse flow. The flow rate at the gas exit 2 was 3 ~ 5 times larger than the flow rate at the gas exit 1.

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

A Study for Faliure Examples Involved Diode, Thermo Sensor and Wiring Short of Electronic Control A/C System in a Vehicle (승용자동차 전자제어 에어컨 장치의 다이오드, 써모센서와 배선단락에 대한 고장사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Jeong Ho;Moon, Hak Hoon;You, Chang Bae;Hwang, Han Sub;Lim, Chun Moo;Jung, Dong Hwa;Na, Yun Whan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • The purpose of this paper is to study for a failure examples producing in electronic control air conditioner in vehicle. The first example, it looked for the repetitive fuse cutting phenomenon that the diode using for a surge voltage prevention of inner A/C relay damaged because of no absorbing the surge voltage by short of diode when the A/C is off. The second example, it knew the icing phenomenon of evaporator that the A/C ECU didn't control the A/C because of inner cutting of fin thermo sensor. The third example, it verified the operation trouble phenomenon because of the A/C switch and for sensor burned in flames by short phenom enon when the sheath of the cable has peeled off. Therefore, the driver have to manage the optimism system of a car by thoroughgoing inspection and improvement the failure phenomenon.

A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model (도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가)

  • Tak, Yong Hun;Kim, Jae Dong;Kim, Young Do;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.395-406
    • /
    • 2016
  • Population and development are concentrated by urbanization. Consequently, the usage of underground area and the riverside area have been increased. By increasing impermeable layer, the urban basin drainage is depending on level of sewer. Flood damage is occurred by shortage of sewer capacity and poor interior drainage at river stage. Many of researches about flood stress the unavailability of connection at the river stage with the internal inundation organically. In this study, flood calculated considering rainfall and combined inland-river. Also, using urban runoff model analyze the overflow of sewer. By using results of SWMM model, using flood inundation analysis model analyzed internal drainage efficiency of drainage system. Applying SWMM model, which results to flood inundation analysis model, analyzes internal drainage efficiency of drainage system under localized heavy rain in a basin of the city. The results of SWMM model show the smoothness of internal drainage can be impossible to achieve because of the influence of the river level and sewer overflow appearing. The main manholes were selected as the manhole of a lot of overflow volume. Overflow reduction scenarios were selected for expansion of sewer conduit and instruction retention pond. Overflow volume reduces to 45% and 33~64% by retention pond instruction and sewer conduit expansion. In addition, the results of simulating of flood inundation analysis model show the flood occurrence by road runoff moving along the road slope. Flooded area reduces to 19.6%, 60.5% in sewer conduit expansion scenarios.

Development of the LMFBR Accident Analysis Computer Code (고속증식로 사고분석 코드의 개발)

  • Hee Cheon No
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.47-57
    • /
    • 1984
  • Mathematically-rigorous time-volume averaged conservation equations were simplified to established the differential equations of THERMIT-6S, which is a two-fluid 3-D code. The difference equations of THERMIT-6S were obtained by discretizing the proceeding set of differential equations. The spatial discretization is characterized by a first-order spatial scheme, donor cell method, and staggered mesh layout. For time discretization, a first order semi-implicit scheme treats implictly sonic terms and terms relating to local transport phenomena and explicitly convective terms. The results were linearized by the Newton-Raphson method. In order to construct the reduced pressure equation, the linearized equations were manipulated so that all variables are coupled between mesh cells through only the pressure variable. By simulating numerically the OPERA-15 experiment, it was found that THERMIT-6S is a very powerful code in predicting reactor behavior after sodium boiling including flow coastdown, reversal flow and flow oscillation.

  • PDF

A DC-DC Converter Design with Internal Capacitor for TFT-LCD Driver IC (TFT -LCD 구동 IC용 커패시터 내장형 DC-DC 변환기 설계)

  • Lim Gyu-Ho;Kang Hyung-Geun;Lee Jae-Hyung;Sohn Ki-Sung;Cho Ki-Seok;Baek Seung-Myun;Sung Kwan-Young;Li Long-Zhen;Park Mu-Hun;Ha Pan-Bong;Kim Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1266-1274
    • /
    • 2006
  • A non-overlap boosted-clock charge pump(NBCCP) with internal pumping capacitor, an advantageous circuit from a minimizing point of TFT-LCD driver IC module, is proposed in this paper. By using the non-overlap boosted-clock swinging in 2VDC voltage, the number of pumping stages is reduced to half and a back current of pumping charge from charge pumping node to input stage is also prevented compared with conventional cross-coupled charge pump with internal pumping capacitor. As a result, pumping current of the proposed NBCCP circuit is increased more than conventional cross-coupled charge pump, and a layout area is decreased. A proposed DC-DC converter for TFT-LCD driver IC is designed with $0.18{\mu}m$ triple-well CMOS process and a test chip is in the marking.