• Title/Summary/Keyword: 여과법

Search Result 449, Processing Time 0.024 seconds

Comparison of the filtration performance by different media in pretreatment of seawater desalination by reverse osmosis (여재 종류에 따른 역삼투법 해수담수화 시설 전처리 여과공정의 성능비교)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.215-222
    • /
    • 2009
  • This study compares the performance of the filters with various media in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is used as raw water. The filter performance is evaluated by the filtrate quality and the head loss development. Five media is selected in this study: anthracite, $Filtralite^{(R)}$, sand, Pumice, $AFM^{(R)}$. These media are used in combination for dual media filter and alone for mono media filter. The comparison results show that NC0.8-1.6 is the best $Filtralite^{(R)}$. The dual media filter of NC0.8-1.6 and sand outperformed other filters in particle removal. The dual media filter of anthracite and sand showed good performance in organic removal. The mono media filter of Pumice produced the similar filtrate quality as the mono media filter of sand although the effective size of Pumice is considerably greater than that of sand. Due to big size, head loss development is maintained slow in the filtration of Pumice.

Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis (역삼투법 해수담수화 전처리 여과공정의 최적조건)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

Removal of Heavy Metal Ions by Surfactant Enhanced Ultrafiltration (계면활성제 증진 한외여과에 의한 중금속 이온의 제거)

  • 안순철;김종수;이광래
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.114-115
    • /
    • 1997
  • 1.서론 : 중금속 및 유독한 금속물질을 함유한 기존의 폐수처리법으로는 다양한 방법이 있으나, 계면활성제를 첨가한 분리기술은 환경적인 측면과 경제적인 측면에서 타 공정에 비해 우수함이 입증된바 계속적인 연구개발이 진행되어 왔다. (생략)

  • PDF

디-젤배진용 포집장치의 최근의 연구개발동향

  • 문재덕
    • 전기의세계
    • /
    • v.32 no.9
    • /
    • pp.546-554
    • /
    • 1983
  • 본고에서는 가까운 장래의 디-젤자동차의 증가추세와 그로부터 배출되는 배진량, 배진의 물성, 위험성, 배진의 규제에 대하여 소개하고, 나아가 그 제거법에 대해 세계적으로 연구개발되고 있는 여과장치(filter), 스크라버(scrubbers) 및 전기집진장치(electrostatic precipitators)에 관하여 간략히 소개하고자 한다.

  • PDF

용출액의 pH 변화가 토양내 중금속 용출에 미치는 영향과 그에 따른 국내 토양오염 공정시험방법의 문제점

  • 오창환;유연희;이평구;이영엽
    • Proceedings of the KSEEG Conference
    • /
    • 2003.04a
    • /
    • pp.76-79
    • /
    • 2003
  • 국내의 토양오염 공정시험방법에서는 Zn, Ni 추출시 산분해법에 가까운 방법을 사용하는 반면, Cd, Cu, Pb, $Cr^{6+}$ 추출시 0.1N HCl용액으로 산처리하여 1시간을 진탕한 후 이를 필터로 여과하여 분석용액을 추출하는 용출법을 사용하고 있다(환경부, 2001). 시료내에는 완충 물질이 존재하기 때문에 용출법 사용시 초기 pH 인 1(0.1N HCl)이 유지되지 않아 완충능력이 높은 토양의 경우 현재 국내 공정법상의 용출법이 중금속 오염정도를 추정하는데 적절치 않을 수 있다. (중략)

  • PDF

The Influence of Water Temperature and Salinity on Filtration Rates of the Hard Clam, Gomphina veneriformis (Bivalvia) (수온과 염분의 변화에 따른 연령별 대복 (Gomphina veneriformis: Bivalvia) 의 여과율 변동)

  • Shin, Hyun-Chool;Lee, Jung-Ho;Jeong, Hyo-Jin;Lee, Jung-Sick;Park, Jung-Jun;Kim, Bae-Hoon
    • The Korean Journal of Malacology
    • /
    • v.25 no.2
    • /
    • pp.161-171
    • /
    • 2009
  • The present study was performed to describe the influence of water temperature and salinity on filtration rates of the venus clam, Gomphina veneriformis, a suspension-feeding (filter-feeding) bivalve species. The calmswere collected from the eastern coastal area of Sokcho, Gangneung and Jumunjin at Kangwon-do, Korea, during December 2006 and May 2007. Isochrysis galbana (KMCC H-002) cells as food organisms were indoor-cultured by f/2 medium, and were used to measure the filtration rate of clam. Filtration rates of clam were measured by indirect method. Cell concentration of food organisms were determined by direct counting cells used the hemacytometer under the light microscope. The filtration rates of clams by water temperature sharply increased with temperatures up to $15^{\circ}C$ as optimum temperature and above this temperature, the filtration rates decreased exponentially. Venus clams showed very low filtration rates at low salinity (10-15 psu) and maximum values at high salinity (30-35 psu). Regardless of water temperature and salt change, 2-year class clams showed high filtration rates, but low in 4-year-class. Polynomial regression curves with water temperature were shifted to the left in low temperature region. Thermal coefficient $Q_{10}$ values showed much higher values at low temperature range than at high temperature range, too. These results indicate that the venus clam is more sensitive in cold water. Polynomial regression curves with salinity were shifted to the right in high saline region. According to this study, the venus clam Gomphina veneriformis, subtidal filter-feeding bivalve, was the stenothermal organism, inhabited mainly in low temperature and the stenohaline, in high saline waters.

  • PDF

The Value of Serum Concentration of Cystatin C as a Marker for Glomerular Filtration Rate in Children and Adolescents (소아 및 청소년에서 사구체 여과율의 지표로서 혈청 Cystatin C 농도의 유용성)

  • Jung, Young-Su;Lim, In-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.614-618
    • /
    • 2005
  • Purpose : Cystatin C has been proposed for the assessment of glomerular filtration rate, being more accurate than creatinine determination. We measured serum cystatin C concentrations in the pediatric population, and analysed the correlation between cystatin C and glomerular filtration rate. Methods : Cystatin C and creatinine were measured by the particle enhanced nephelometric immunoassay and Jaffé method, respectively, in 276 children and adolescents without evidence of kidney disease. The glomerular filtration rate was estimated by Schwartz's formula. Results : The mean serum cystatin C concentration was significantly higher in infants under the age of 12 months than in older population. There was a negative correlation between cystatin C and age under 12 months, but not a significant change of cystatin C with age in children older than 12 months. For children older than 12 months, the reference range of cystatin C was 0.46-1.05 mg/L. On the other hand, there was a positive correlation between creatinine and age in the whole population. We also observed a positive correlation between estimated glomerular filtration rate and 1/cystatin C. Conclusion : The measurement of cystatin C is more practical than creatinine for estimating glomerular filtration rate in the pediatric population.

Clarification of Korean Tangerine Juice Using Microfiltration Membrane Process (미세여과 공정을 이용한 제주산 감귤 주스의 청징화)

  • Lee, Eun-Young;Woo, Gun-Jo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.448-457
    • /
    • 1999
  • Citrus fruits are consumed worldwide due to their unique flavor and nutrition value. It is necessary to remove the haze material as well as to minimize the loss of major compounds such as organic acids, sugars, and ascorbic acid in membrane processes for clarification of juice. The objective of our research was to select the best membrane among one surface filter (Whatman No.4) and five microfiltration filters (GF/A, GF/D, GF/F, Gelman, and SM). Tangerine fresh blended with three times of water was partially clarified with 170 mesh followed by prefiltration in a Samduck filtration system. The best membrane was selected by measuring the amounts of major compounds in the permeates as well as the flux which were statistically analyzed with SAS program. The foulants on the membrane surface were observed by SEM. The flux of GF/A and GF/F decreased with time at probability 0.10. Gelman, SM, and GF/D maintained the stable flux. Gelman showed the highest total scores including nutritive value (the amounts of citrate, malate, and ascorbic acid) and purchasing need (brix and color). Therefore, the microfiltration membrane process was a very effective method in tangerine juice clarification and Gelman type A/E was proved to be the best membrane among the five microfiltration membranes.

  • PDF

Improvement of Water Quality by Corona Discharge Plasma-activated Water in a Tilapia Recirculating Aquaculture System (코로나 방전-플라즈마 처리수의 틸라피아 순환여과양식시스템 수질 개선 효과)

  • You, Jin Ho;Mun, Seong Hee;Oh, Hyeon Ji;Park, Tae Sup;Kwon, Joon Yeong
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2020
  • Disinfection and maintenance of rearing water in aquaculture is an essential element for the prevention of fish diseases. This is especially important in recirculating aquaculture systems (RAS) in which fish are reared at high density using recycled water. In this study, tilapia was reared in two different RAS (one with plasma generator - PW system, another without plasma generator - No PW system). In plasma treated group, UVT% of water was improved clearly, and the number of heterotrophic bacteria decreased significantly after 40 days. Total weight gain of tilapia in PW system was significantly higher, and other growth indicators were also relatively higher although not statistically significant. In addition, the fish in PW system had a 100% survival rate, and there were no histological differences between fish from both systems. Fish did not seem to be affected by the toxicity of ROS. In conclusion, it is expected that plasma water can effectively deactivate fish pathogens and improve the quality of rearing water.

Characterizations of Assimilable Organic Carbon, Biodegradable Dissolved Organic Carbon, and Bacterial Regrowth in Distribution Systems by Water Treatment (배수관망에서 수처리에 의한 AOC, BDOC및 세균성장의 특성)

  • Chang, Young-Cheol;Kweon Jung;Yoo, Young-Sik;Kang, Mi-Hye;Andrew A. Randall
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.42-52
    • /
    • 2002
  • Two full-scale distribution systems, one treating water by ozonation and another treating water by nanofiltration in parallel with lime softening, were monitored for bacterial growth. Both systems kept disinfectant residuals surf as chlorine and chloramine in their respective distribution systems. Bacterial growth was assessed by heterotrophic plate counts (HPC) on R2A agar. In the distribution systems fed by ozonated water, HPCs were correlated ($R^2$= 0.97) using an exponential model with the assimilable organic carbon (AOC) at each sampling site. Also, it was observed that ozonation caused a significant increase in the AOC concentration of the distribution system (over 100% increase) as well as a significant increase in the bacterial counts of the distribution system (average increase over 100%). The HPCs from the distribution systems fed by nanofiltration in parallel with lime-softening water also displayed an exponential correlation ($R^2$ = 0.75) with an exponential model based on AOC. No significant correlation was found between bacteria growth on R2A agar and BDOC concentrations. Therefore, in agreement with previous work, bacterial growth in the distribution systems was found to correlate with AOC concentrations.