An Experimental Study on the Optimum Design of Sirocco Fan by Using Taguchi Method (다구찌 방법을 이용한 시로코 홴의 최적설계에 관한 실험적 연구)

  • Kim, Jang Kweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.761-768
    • /
    • 1999
  • This paper is studied to find the optimum condition of double-inlet Sirocco fan installed in an indoor PAC for low noise operation by the Taguchi method. The goal of this study is to obtain the best combination of each control factor which results in a desired flowrate of Sirocco fan with minimum variability. In this study, the parameter design of the Taguchi method is adopted for robust design by the dynamic characteristic analysis using orthogonal arrays and S/N ratios. The flowrate measurements are conducted by using a multiple-nozzle-type fan tester according to the orthogonal array L9($3^4$). The results of this study can be summarized as follows ; (i) The optimum condition of control factor is a set of where A is an inner to outer diameter ratio($D_1/D_2$), B is a width to outer diameter ratio($L/D_2$), C is a blade attachment angle(${\theta}$) and D is a number of blade(Z), (ii) The flowrate under the optimum condition satisfies the equation $y=0.0384{\cdot}M$ where M is a signal factor, namely number of revolution. The flowrate performance improves about 7.3% more largely as compared with the current condition, which results in about 35RPM reduction of number of revolution for the target flowrate $18.5m^3/min$, and (iii) The sensitivity analysis shows that the major factors in contribution to flowrate performance are A, B, and D ; the percentage contributions of each control factor are 44.01%(Z), 26.77%($D_1/D_2$) and 20.42%($L/D_2$).

A study on the Characteristics of a Centrifugal Fan Vibration and Noise (Centrifugal Fan 송풍기의 진동.소음 특성에 관한 연구)

  • 김태형;김옥현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.999-1003
    • /
    • 1992
  • Because of low noise and small size with huge capacity, a centrifugal fan is widely used for ventilation, air-conditioner and so on, which are very near to human life. Because of the complexity of its vibration and noise generation mechanics, most of researches on them are based on experimental methods. This study is to characterize the centrifugal fan noise and vibration. It is considered that noise is composed of the structural vibration noise and the air flow induced aerodynamic noise. To decouple the structural vibration noise the centrifugal fan is masked with an adhesive tape, such that air blowing is prohibited thus only the structural vibration noise is extracted. The noise level and characteristics in the frequency domain are verified and compared with those of total mixed one. This study shows some significant results that the structural vibration noise has relatively narrow band power spectrum compared with the total mixed one and has a strong periodicity. The sound level is lowered about 5dB by the removal of air flow with the masked fan for an air-conditioner used in this study.

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF

Computational Flow Analysis on the Flow Field Improvement of an Indoor RAC by LES (LES에 의한 RAC 실내기의 유동장 개선에 관한 전산유동해석)

  • Kim, J.K.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.16 no.3
    • /
    • pp.29-36
    • /
    • 2012
  • The computational flow analysis using LES technique was introduced to investigate the flow field improvement of an indoor RAC chassis consisting of a rear-guider, a stabilizer and a cross-flow fan. This unsteady three-dimensional numerical analysis was carried out by the commercial SC/Tetra software. The edge blocks were adopted in this study as a tool for the flow field improvement of an indoor RAC. In view of the results so far achieved, the edge blocks cause the center of an eccentric vortex to be stable along all length of a cross-flow fan, and then, the static pressure and the velocity vector show a stable distributions. In consequence, because the edge blocks eliminate a reverse flow near the edges, an exhausting flow becomes to be stable and uniform.

Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Design Factors of an Indoor Room Air-Conditioner (룸에어콘 실내기의 설계인자 변화에 따른 관류홴의 공력성능 연구)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.9 no.3
    • /
    • pp.33-38
    • /
    • 2005
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The purpose of this paper is to investigate the effects of a rear-guider and a stabilizer on the aerodynamic performance of a cross-flow fan. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. This experiment was carried out with a constant revolution number of 700 rpm in a cross-flow fan installed in the fan tester. The static pressure, flowrate, torque, and revolution number were measured in this paper. Also, the pressure coefficient and the efficiency were analysed according to the various assembly conditions using a stabilizer setup angle, a stabilizer clearance, and a rear-guider clearance in the indoor room air-conditioner.

  • PDF

차세대 Embedded 마이크로프로세서 기술 동향

  • Lee, Hui
    • The Magazine of the IEIE
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 2001
  • 1970년대에 개발된 마이크로 프로세서는 제어기기 분야 및 소형 컴퓨터에서 주로 사용되어 오다가 1980년대에 이르러 RISC(Reduced Instruction Set Computer) 구조의 도입으로 중대형 컴퓨터에 이르기까지 광범위하게 사용되고 있다. 또한 반도체 기술의 급격한 발전으로 슈퍼스칼라 구조가 마이크로 프로세서에서도 적용되고 있으며 동작 속도도 수백 MHz에 이르고 있다. 마이크로 프로세서는 프로그램을 수행하기 위해서 프로그램과 데이터를 메모리로부터 읽어 와야 한다. 그런데 메모리 용량은 빠른 속도로 증가하고 있지만 동작 속도는 마이크로 프로세서의 동작 속도에 크게 미치지 못하고 있다. 1980년에 DRAM의 접근 속도는 250nsec이었으나 1998년에 RDRAM의 동작속도는 300MHz로 70여배 빨라졌다. 그러나 마이크로프로세서는 1980년에 8086의 동작 속도가 8MHz이던 것이 1998년에는 팬티엄-2가 500MHz에 이르고 있다. 더욱이 팬티엄-2는 슈퍼스칼라 구조이므로 이를 감안하면 1GHz 이상에 이르러 120여 배 빨라진 것을 알 수 있다. 이와 같은 메모리 속도와 마이크로 프로세서 속도 차이에 더하여, 메모리와 마이크로 프로세서를 인쇄 회로 기판에서 연결하는데 따른 물리적 특성은 변화하지 않으므로 데이터 전송 폭을 넓히는 것에는 한계가 있다. 따라서 향후 컴퓨터 성능 발달을 제한하는 주요 요소 중 하나는 마이크로 프로세서와 메모리 사이의 데이터 전송 폭이다. 프로그램과 데이터가 메모리에 저장되는 본 뉴먼 방식의 컴퓨터에서 데이터 전송 폭을 줄이기 위해서는 코드 밀도(Code Density)가 높은 컴퓨터 구조를 연구하는 것이 필요하다. 한편 마이크로 프로세서는 실장 제어용으로 거의 모든 전자 제품 및 자동화 기기에서 채용하고 있다. 특히 냉장고, 에어콘, 전축, TV, 세탁기 등 가전기기와 Fax, 복사기, 프린터 등 사무용기기와 자동차, 선박, 자동화기계 등 사무 및 산업용 기기와 PDA(휴대용 정보 기기), NC(Network Computer) 등 정보 기기 그리고 각종 오락기, 노래 반주지 등 정보 기기 등에서 사용하는 실장 제어용 마이크로 프로세서 시장은 매년 10% 이상씩 성장하고 있으며, 21세기 산업을 주도하는 핵심 기술로 자리 매김하고 있다. 이러한 실장 제어용 기기는 마이크로 프로세서와 메모리 및 입출력 자이가 하나의 반도체에 집적되는 경우가 많다. 그런데 반도체 가격은 반도체 크기에 따라 결정되며, 가장 넓은 면적을 차지하는 것은 메모리이다. 따라서 반도체 가격을 낮추기 위해서는 메모리 크기를 줄여야 하며, 이를 위해서 또한 코드 밀도가 높은 컴퓨터 구조에 대한 연구가 필요하다. 최근에는 322비트 RISC 명령어를 16비트 명령어로 축약한 구조가 연구되었다. ARM-7TDMI는 ARM-7의 16비트 축약 명령어 구조이며, TR4101은 MIPS-R3000의 16비트 축약 명령어 구조이다. 이들 16비트 축약 명령어 RISC는 종래 RISC와의 호환성을 위하여 2가지 모드로 동작하므로 구조가 복잡하고, 16비트 명령어에서는 8개의 레지스타만을 접근할 수 있으므로 성능이 크게 떨어지는 단점을 가진다.

  • PDF

Implementation of A Monitoring System using Image Data and Environment Data (영상정보와 환경정보를 이용한 실내 공간 모니터링 시스템 구현)

  • Cha, Kyung-Ae;Kwon, Cha-Uk
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The objective of this study is to design a system that automatically monitors the state of interior spaces like offices where lots of people are coming and going through image data and environment data, which includes temperature, humidity, and other conditions, and implement and test related application programs. In practice, there are lots of image data automatically obtained by unmanned equipments, such as certain types of CCTVs, for monitoring situation in usual interior spaces. This image data can be used as a more effective manner by establishing a system that recognizes situation in specific interior spaces based on the relationship between image and environment data. For instance, it is possible to perform unmanned on/off controls for various electronic equipments, such as air conditioners, lights, and other devices, through analyzing the data acquisited from environment sensors (temperature, humidity, and illumination) as dynamic states are not maintained for a specified period of time. For implementing these controls, this study analyzes environment data acquisited from temperature and humidity sensors and image data input from wireless cameras to recognize situation and that can be used to automatically control environment variables configured by users. Experiments were applied in a laboratory where unmanned controls were effectively performed as automatic on/off controls for the air conditioner and lights installed in the laboratory as certain motions were detected or undetected for a specified period of time.