• Title/Summary/Keyword: 에너지 텍스타일

Search Result 7, Processing Time 0.027 seconds

A Study on the Application Trends of Next-Generation Solar Cells and the Future Prospects of Smart Textile Hybrid Energy Harvesting Devices : Focusing on Convergence with Industrial Materials (차세대 태양전지의 활용 동향 및 스마트 텍스타일 하이브리드 에너지 하베스팅 소자의 미래전망에 관한 연구 : 산업 소재와의 융합 중심)

  • Park, Boong-Ik
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.151-158
    • /
    • 2021
  • In this paper, we analyzed the latest research trends, challenges, and potential applications of next-generation solar cell materials in various industrial fields. In addition, future prospects and possibilities of Smart Textile Hybrid Energy Harvesting Devices that will supply electricity by combining with wearable IoT devices are presented. The hybrid textile energy harvesting device fused next-generation solar cells with tribo-piezoelectric devices will develop into new 'Convergence Integrated Smart Wear' by combining the material itself with wearable IoT devices in the era of the 4th industrial revolution. The next-generation nanotechnology and devices proposed in this paper will be applied to the field of smart textile with an energy harvesting function. And we hope it will be a paradigm shift that evolves into creative products which provide AI services such as medical & healthcare by convergence with the future smart wear industry.

Thermal characteristics of energy textile by performing in-situ thermal response test (현장 열응답시험을 통한 에너지 텍스타일의 열적 거동 평가)

  • Lee, Chulho;Yoon, Sangbong;Han, Eunseon;Jeoung, Jae-Hyeung;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.167.2-167.2
    • /
    • 2010
  • 본 연구에서는 지열 에너지원으로써 터널 내부 벽면의 항온성을 이용하여 터널 외벽에 텍스타일 형태의 열교환기를 설치하고 열적 거동을 평가하였다. 터널의 라이닝 부분에서는 여러 가지 요인에 의해 지하수가 터널 내부로 유입하게 되므로 지하수의 유무에 대한 열적 거동 및 유동액의 순환 속도에 따른 영향, 열교환 파이프 배열 형태에 따른 영향을 현장 시험 시공과 현장 열응답시험을 통하여 평가하고자 하였다. 또한 3-D 유한체적해석 프로그램(FLUENT)을 이용하여 숏크리트와 라이닝의 열전도도를 고려한 열교환기의 성능을 분석하였다. 수치해석 결과 열교환 파이프 주변에 지하수의 흐름이 존재할 경우 열전달이 상대적으로 더 원활히 이루어졌으며 순환속도가 빠를 때 보다 느릴수록 효율이 높게 나타났다. 또한, 파이프의 간격이 넓을수록, 파이프의 길이가 길수록 효율이 높게 나타났다. 라이닝 및 숏크리트의 열전도도가 증가함에 따라 에너지 텍스타일의 열전달 효율이 높게 나타났다. 현장 시험을 통해 비슷한 길이의 파이프가 사용된 경우, 파이프 배열 형태에 따라 수평형보다는 수직형 배열의 효율이 높게 측정되었다.

  • PDF

Study on Thermal Performance of Energy Textile in Tunnel (터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구)

  • Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1907-1914
    • /
    • 2013
  • Textile-type heat exchangers installed on the tunnel walls for facilitating ground source heat pump systems, so called "energy textile", was installed in an abandoned railroad tunnel around Seocheon, South Korea. To evaluate thermal performance of the energy textile, a series of long-term monitoring was performed by artificially applying daily intermittent cooling and heating loads on the energy textile. In the course of the experimental measurement, the inlet and outlet fluid temperatures of the energy textile, pumping rate, temperature distribution in the ground, and air temperature inside the tunnel were continuously measured. From the long-term monitoring, the heat exchange rate was recorded as in the range of 57.6~143.5 W per one unit of the energy textile during heating operation and 362.3~558.4 W per one unit during cooling operation. In addition, the heat exchange rate of energy textile was highly sensitive to a change in air temperature inside the tunnel. The field measurements were verified by a 3D computational fluid dynamics analysis (FLUENT) with the consideration of air temperature variation inside the tunnel. The verified numerical model was used to evaluate parametrically the effect of drainage layer in the energy textile.

Application textile-type geothermal heat exchanger for tunnel (텍스타일형 지중열교환기의 터널에서의 적용)

  • Lee, Chul-Ho;Lee, Kang-Ja;Gil, Hu-Jeong;Jeoung, Jae-Hyeung;Choi, Hang-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.604-607
    • /
    • 2009
  • The geothermal energy have been developed as the pro-environmental and the substantial long-term energy. Recently energy foundations and other thermo-active ground structures have been developed to enhance the use of geothermal energy. In this research, a tunnel wall is focused as a source of geothermal energy. If the tunnel wall can be used for geothermal source, it can provide relatively lower cost because it is not necessary to make a deep borehole like in case of closed-loop vertical ground heat exchanger. For analyzing efficiency of heat exchanger in tunnel, laboratory tests and the numerical analyses are performed.

  • PDF

A study on thermal behavior of energy textile by performing in-situ thermal response test and numerical simulation (현장 열응답 시험과 수치해석을 통한 터널에 적용된 에너지 텍스타일의 열적 거동 연구)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Jeoung, Jae-Hyeung;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.325-335
    • /
    • 2010
  • A new geothermal energy source obtained from a tunnel structure has been studied in this paper. The geothermal energy is extracted through a textile-type ground heat exchanger named "Energy Textile" that is installed between a shotcrete layer and a guided drainage geotexitle. A test bed was constructed in an abandoned railway tunnel to verify the geothermal heat exchanger system performed by the energy textile. To evaluate the applicability of the energy textile, we measured the thermal conductivity of shotcrete and lining samples which were prepared in accordance with a common mixture design. An overall performance of the energy textile installed in the test bed was evaluated by carrying out a series of in-situ thermal response test. In addition, a 3-D finite volume analysis (FLUENT) was adopted to simulate the operation of the ground heat exchanger being encased in the energy textile with the consideration of the effect of the shotcrete and lining thermal conductivity.

  • PDF

Study on long-term monitoring of heat exchanger installed in the tunnel lining (터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구)

  • Lee, Chulho;Park, Moonseo;Choi, Hangseok;Sohn, Byunghu;Jeoung, Jaehyeung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

Static Cyclic Loading Test of the Seismic and Energy Simultaneous Retrofit Panel for Existing Unreinforced Masonry Buildings (기존 비보강 조적조 건축물의 내진 및 에너지 동시보강패널 정적반복가력실험)

  • Choi, Hyoung-Wook;Lee, Sang-Ho;Choi, Hyoung-Suk;Kim, Tae-Hyeong;Baek, Eun-Rim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.81-90
    • /
    • 2020
  • A textile and capillary tube composite panel(TCP) was developed to simultaneously retrofit the seismic performance and the energy efficiency (e.g. heating or insulation performance) of existing unreinforced masonry (URM) buildings. TCP is a light-weight mortar panel in which carbon textile reinforcements and capillary tubes are embedded. Textile reinforcements plays a role of seismic retrofit and capillary tubes that hot water circulates contribute to the energy retrofit. In this paper, the static cyclic loading tests were performed on the masonry walls with/without TCP to understand the seismic retrofit effect of TCP retrofit and the results were summarized. The results of the test showed that the TCP contributed to increase the capacity of the Shear strength and ductility of the URM walls. In addition, the deformation of the wall after cracking was substantially controlled by the carbon textile.