• Title/Summary/Keyword: 에너지 창

Search Result 321, Processing Time 0.02 seconds

Evaluation of long-term performance for single-stage desalination system with solar energy (태양에너지 해수담수화 실증시스템 장기 운전 열성능)

  • Kwak, Hee-Youl;Yoon, Eung-Sang;Joo, Moon-Chang;Joo, Hong-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.172-177
    • /
    • 2008
  • This study was carry out evaluation of long-term performance for the decentralized desalination system with the solar thermal system and the photovoltaic power system. First operating demonstration system was set up in Cheju in 2006. These system comprises the desalination unit with designed daily fresh water capacity of $2m^3$ and is supplied by a $120m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank, and a 5kW photovoltaic power generation supply the electricity for hydraulic pumps to move the working fluids. In a clear day more than 400W/$m^2$, the daily fresh water showed to produce more than about 500liter, and from January, 2007 to October, 2008 for 2 years, solar irradiance daily averaged was measured 370W/$m^2$, the daily fresh water yield showed that can be produced about 330liter.

  • PDF

Design and Implementation of Automatic Control System in Room using Sensor (센서를 이용한 자동 실내 온도 제어시스템 설계 및 구현)

  • Jeong, Gyu-Tae;Lee, Eun-Jin;Kim, Heung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.326-328
    • /
    • 2015
  • Function of the window of the building is an environment of the room through the entry of solar radiation. It is vulnerable to significant energy conservation off the thermal efficiency. Also this summer, cooling costs are weighted because of excessive solar radiation. In this paper, we develop a windows automatic control system to use the indoor environmental information, such as home temperature, humidity, light intensity, solar radiation. The system collects the indoor environment information using a variety of sensor, using the collected information, and controls the motor to the system to control the window.

  • PDF

Query Flooding of Multiple Static Sinks for Wireless Sensor Networks (센서 망에서의 다중 정적 싱크의 쿼리 플러딩)

  • Jin, Min-Sook;Choi, Young-Hwan;Lee, Eui-Sin;Park, Soo-Chang;Yu, Fu-Cai;Kim, Sang-Ha
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10d
    • /
    • pp.273-276
    • /
    • 2007
  • 전형적인 센서 네트워크는 사용자, 싱크 그리고 센서들로 구성되며, 사용자와 싱크간은 기반 망으로 연결되어 있음을 가정한다. 그러나, 재난지역이나 전투지역에서의 실제 사용자들은 기반 망이 없는 밀집 된 센서 영역 내부를 이동하면서 다양한 정보를 받아 임무 수행할 수 있기를 원한다. 따라서, 사용자와 싱크 간 센서 노드만이 통신 채널로 유일하게 존재하는 상황에서 사용자의 이동성 지원이 필요 된다. 다중의 정적 싱크 기반 센서 망 구조에서 사용자의 이동성이 고려된 네트워크에서 사용자가 원하는 다양한 정보를 얻고자 하여 싱크에게 쿼리를 보냈을 때 각 싱크는 정보를 찾고자 한다. 기존 제안된 알고리즘들은 하나의 패킷에 수많은 쿼리를 담아 주기적인 메시지 전송을 요구하기 때문에 에너지 효율성이 떨어진다. 이에, 본 논문에서는 싱크가 정보를 찾고자 할 때 시간 동기화 기법을 사용하여 에너지 소모를 다소 줄이고자 한다. 각각의 싱크에 수많은 쿼리를 할당하여 원하는 정보를 찾도록 하는 임무로 플러딩할 때 패킷에 실어야 하는 값을 최소화 하여 에너지 효율성과 속도를 빠르게 하여 네트워크 수명을 연장하는 장점을 갖는다. 마지막으로 시뮬레이션시에 검증할 매트릭스와 향후 연구방향을 제시한다.

  • PDF

The study of ignition characteristics of solid propellant using Arc Image Furnace (광학특성을 이용한 고체추진제 점화특성 연구)

  • Yoo, Ji-Chang;Kim, In-Chul;Jung, Jung-Yong;Lee, Kyung-Joo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.225-228
    • /
    • 2007
  • The objective of this study is to characterize design parameters of rocket igniters for composite, double base and nitramine propellant. Arc image furnace and fiber optics surface reflectometer were used to measure ignition delay time and reflected optical energy of several compositions of composite, double base and nitramine base rocket propellant at different pressure levels each other. The order of ignitability was double base > composite > Nitramine propellants at initial pressure of over 75 psia. The highest ignition energy was needed to ignite nitramine propellant, however, as the pressure increased up to the range of $75{\sim}400$ psia as the ignition delay time decreased abruptly. The absorbtion of radiation energy could be increased by the addition of small amount of opacifiers as carbon black, ZrC, WC and burning catalyst.

  • PDF

An Improved Motion Compensated Temporal Filtering for Efficient Scalable Video Coding (효율적인 스케일러블 비디오 부호화를 위한 향상된 움직임 보상 시간적 필터링 방법)

  • Jeon, Ki-Cheol;Kim, Jong-Ho;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5C
    • /
    • pp.520-529
    • /
    • 2007
  • In this paper, we study the characteristics of parameters which are related to performance of MCTF which is a key technique for wavelet-based scalable video coding, and propose an improved MCTF method. The proposed MCTF method adopts the motion estimation of which motion vector field is distributed more uniformly using variable block sizes. By using the proposed method, the decomposition performance of temporal filter is improved, and the energy in high-frequency frames is reduced. It can help the entropy coder to generate lower bitrate. From simulation results, we verify the decomposed energy on high-frequency frame using the proposed method is reduced by 25.86% at the most in terms of variance of the high-frequency frame.

The Application and Evaluation of Heating and Cooling System by Seawater Heat Source for Research Center Building in Jeju (제주지역 연구소 건물의 해수열원 냉난방시스템 적용 및 평가)

  • Park, Jin-Young;Kim, Sam-Uel;Chang, Ki-Chang
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.26-31
    • /
    • 2013
  • Use of heat from seawater could be different from the weather conditions of a coastal city and seawater temperatures near the city. It will be a good option to use surface layer water with Heat Pump system for using seawater cooling/heating in Jeju. The study investigates the proper depth for seawater heat gain of Jeju area in Korea. Sampling points are 0, 10, 20, 30m from the surface of the Sea. Seawater temperature does not change significantly according to the depth in winter, while the temperature is quite different according to the depth in summer. In this study, it is analyzed to compare existing system and seawater heat source system for target buildings on Jeju. And this systems are calculated a initial cost.

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

Life-Cycle Analysis of the River Water Unutilized Energy System (LCC 분석에 의한 하천수 미활용에너지 이용시스템의 경제성 평가)

  • Park Il-Hwan;Yoon Hyung-Kee;Chang Ki-Chang;Park Jun-Taek;Park Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.596-604
    • /
    • 2005
  • This paper presents the work on evaluating the LCC (Life-Cycle Cost) of a heat pump system as unutilized energy system. The river water as an unutilized energy source was used for the heat source of heat pump system. LCC analysis is a concrete method for evaluating the economical efficiency of energy facilities of building. The present case study shows an example of adequate use of the LCC analysis on a heat pump system and conventional gas boiler and refrigerator for building heat supply. A life cycle of 20 years was used to calculated net present value of energy cost. Over a 20 year life cycle, the energy cost could be reduced by 612 million won if a heat pump system were used instead of a conventional boiler and an absorption refrigerator.

A Study on the Potential Energy Reserve Amount of Domestic River Water as Unutilized Energy Resource (국내 하천수 미활용에너지 부존량에 관한 조사연구)

  • Park Il-Hwan;Yoon Hyung-Kee;Park Jun-Taek;Chang Ki-Chang;Lee Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.521-528
    • /
    • 2005
  • This study has been conducted to investigate the potential energy reserve amount of river water as energy resource with useful temperature difference. Since the river water temperature is one of the primary parameters deciding the potential amount of river water energy reserve amount, the climate change effects on it are critically important. In this study, the heat exchange processes and the inter-relationship between the air temperature and river water temperature have been theoretically analyzed. Based on the present study, the potential energy reserve of river water is calculated to amount to 192,000 Tcal/year. Among this, it is estimated that approximately 2,000 Tcal/year can be directly utilized for heat pump energy sources.

A Study on the Coating Method of Platinum based Catalyst for Odor Gas and VOCs Oxidation (악취가스 및 휘발성 유기 화합물 산화를 위한 백금계 촉매의 코팅 방법에 관한 연구)

  • Shin, Jung Hun;Jung, Min Gie;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.32 no.5
    • /
    • pp.497-503
    • /
    • 2021
  • In this study, different methods to coat honeycomb and metal foam substrate with platinum/titania for removing odor gases and volatile organic compounds were investigated. Among them, the powder coating and the nano coating were compared. Scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX) analysis was used to investigate the surface conditions and exposed platinum composition ratios on honeycomb and metal foam. Also, the catalytic oxidation performance of toluene, trimethylamine and isopropyl alcohol was compared according to the coating method.