• Title/Summary/Keyword: 에너지 절감량

Search Result 439, Processing Time 0.025 seconds

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).

CFD Analysis for Microclimate of Venlo Type Glasshouse with the Screen Height and Air-inflow Quantity (스크린설치높이·공기유입량 차이에 따른 벤로형 유리온실 미기상 CFD 유동해석)

  • Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.52-61
    • /
    • 2020
  • The natural change of winter night temperature from 00:00 to 04:30 O'clock with the different height of thermal screen in a venlo type glasshouse (W59×L68×H5.9 m) was studied using computational fluid dynamics (CFD). At the early stage of CFD analysis, the room temperature decrease of glasshouse with the 5.9 m height of thermal screen were faster than it with the 4.1m height of thermal screen, but at 2 hr after analysis it was slower than in it with the 4,1m, the temperature difference was 0.6℃ after 4 hr. If we consider that turn on the heater when the temperature were decrease below 13℃ at 1hr after CFD analysis, it is good for energy saving in the glasshouse with the 4.1 m height of thermal screen rather than in it with the 5.9 m height, because of the temperature decrease were slow during 2 hrs after analysis. The airflow at the height of 2 m which were grown tomato were fast and wide in the glasshouse with the 5.9 m height thermal screen rather than in it with the 4.1 m, the speed difference was 0.034m·s-1 at 1hr after CFD analysis. The effect of temperature decrease in summer season were compared with the different height of shading screen from 12:00 to 14:30 O'clock. The height of shading screen were 5.7, 3.9 m, the gap of it were 30%. The air-inflow quantity by the fan with duct at lower part of venlo glasshouse was 0.67 ㎥·s-1 until 1hr and to increase 3 times of it from 1hr after analysis. The roof window were open 100%. Until 1hr of CFD analysis, the temperature in the 30% open of shading screen was 0.9℃ higher than in the none shading screen. From 13:00 O'clock when the air-inlet quantity to increase 3 times, the temperature in case 30% gap of shading screen were decreased compare with the none shading screen, the temperature difference was 0.5℃ at 14:30 O'clock. The temperature on the floor surface in case 30% gap of shading screen were lower with it's height increase, the temperature difference was 8℃ compare with none shading screen. The relative humidity difference were insignificant by the height and gap of shading screen.

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Effects of Feeding Split Diets for a.m. and p.m. on Laying Hen Performance and Feed Cost (산란계에 대한 오전용 사료와 오후용 사료의 별도 급여가 산란능력과 경제성에 미치는 영향)

  • 이규호;정연종
    • Korean Journal of Poultry Science
    • /
    • v.23 no.1
    • /
    • pp.27-37
    • /
    • 1996
  • This experiment was carried out to study the effects of feeding split diets for a.m. and p.m. on laying hen performance and feed cost with 480 ISA Brown layers for three periods during 32∼36, 52∼56 and 72∼76 wk of age, respectively. The control group(C) was fed a conventional single diet throughout the day and split diet groups (T$_1$, T$_2$, T$_3$, T$_4$ and T$\_$5/) were offered high energy-high protein-low Ca diets, and low energy-low protein-high Ca diets in a.m. and p.m., respectively. In split diet groups, feed intake, ME and CP consumption, and feed cost were significantly reduced(P<0.05) compared to the C, while the hen-day egg production was significantly improved. However, the average egg weight was not influenced by the feeding system. Due to the reduced daily feed, ME, and CP intakes, and the improved egg production, the conversions of feed, ME, CP, and feed cost required per kg egg mass were also significantly improved (P<0.05) in splits diet groups. Among split diet groups, the T$_2$ group fed the diet devoid of Ca supplement from the conventional laying hen diet in a.m., and the diet containing the Ca supplement 2 times the conventional diet in p.m., was superior in conversion of nutrients and feed cost per kg egg mass to the other split diet groups. It was concluded that daily feed and nutrients cousumption and daily feed cost could be reduced 5∼6% while hen-day egg production could be improved about 4%, so that about 10% of the feed and nutrients and feed cost per kg egg mass could be spared by introducing the split diet feeding for a.m. and p.m. based on T$_2$ treatment in laying hens.

  • PDF

Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse (온수배관에 의한 온실 내부의 온도변화)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Bae, Seoung-Beom;Kim, Hyeon-Tae;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • This study was performed to obtain a heat saving effect and enhance the efficiency of a greenhouse by using a hot water piping in order to minimize the operating costs of a greenhouse as oil prices continue to rise. This method also reduces the likelihood of accidents caused by snowdrifts in regions with heavy snowfall. In general, the experimental plot was $2.0{\sim}6.0^{\circ}C$ higher than the control plot. When the skylight felt was opened, the minimum temperature was in the range of $3.0{\sim}12.0^{\circ}C$. Therefore, we judged that damage caused by snowdrifts may be prevented partly by active heating. The temperature difference inside of the greenhouse by height was insignificant. The maximum heating load of the greenhouse according to crop was respectively about $37,000kcal{\cdot}h^{-1}$ and $41,700kcal{\cdot}h^{-1}$. During the experiment, the heat value of each designed temperature in the range of the minimum ambient temperature $-11.9{\sim}4.0^{\circ}C$ was about 95,000~322,000 kcal and it was in the range of $6,050{\sim}20,900kcal{\cdot}h^{-1}$. If it is compared with the maximum heating load, it can be shown that about 15~56% of the heating energy can be supplied. The total heat value and the amount of power consumption were 2,629,025 kcal and 677.3 kWh respectively during the experiment. If it is heated with diesel, a fossil fuel, the consumption during the experiment was 291 L and the cost was 331,700won. Total cost of using electric power was about 24,400 won and it is shown that it is about 7.5% of the cost of diesel consumption. Also, if the total amount of power consumption is converted into energy, it is approximately 582,200 kcal and the energy was just about 22% of the total heat value.

A Study on the Utility Interactive Photovoltaic System Using a Chopper and PWM Voltage Source Inverter for Air Conditioner a Clinic room (병실 냉.난방을 위한 초퍼와 PWM 전압형 인버터를 이용한 계통 연계형 태양광 발전시스템에 관한 연구)

  • Hwang, L.H.;Na, S.K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.360-369
    • /
    • 2008
  • The solar cells should be operated at the maximum power point because its output characteristics were greatly fluctuated on the variation of insolation, temperature and load. It is necessary to install an inverter among electric power converts by means of the output power of solar cell is DC. The inverter is operated supply a sinusoidal current and voltage to the load and the interactive utility line. In this paper, the proposes a photovoltaic system is designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper is operated in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature for solar cell has typical dropping character. The single phase PWM voltage source inverter is consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be develop continuously by connecting with the source of electric power for ordinary using. It can be cause the efect of saving electric power, from 10 to 20%. The single phase PWM voltage source inverter operates in situation, that its output voltage is in same phase with the utility voltage. The inverter are supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection (홍삼 내공검출을 위한 X-선 영상처리기술)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.457-463
    • /
    • 2002
  • 이 연구는 x-선 투과영상을 이용하여 홍삼의 내공을 검출하기 위하여 수행되었다. 이를 위하여 x-선관에 조사되는 x-ray 양의 차이에 따른 위치별 밝기 값 차이를 보정하고 내공 검출에 적합한 영상처리 알고리즘을 개발하였다. 주요연구 결과를 요약하면 다음과 같다. 1) x-선관에 조사되는 x-ray양은 중심에서 가장자리로 갈수록 감소하며, 이것은 위치에 따른 gray 값의 분포가 달라지게 되는 원인이 되었다. 2) 홍삼을 2치화 하기 위해서는 동일한 x-선 조사강도에서 입력된 원 영상에서 빈 영상을 뺀 감산 영상을 만들어 줌으로써 가능하였다. 3) 조사강도 별 감산영상처리 결과 36kV/4.15mA와 39kV/4.15mA에서는 조사량이 많아서 홈삼 지근 부분의 영상이 손실되는 경우가 발생하였다. 4) 내공 검출을 위해서는 정상부분과 내공부분의 자기 값 차이를 크게 하는 전처리 영상을 만들 필요가 있었고, multiple 감산영상에서 뚜렷한 골짜기가 나타났으나 주근의 내공부분의 밝기값 보다 지근의 정상부분의 자기 값이 더 낮게 나타나 이를 보정하기 위하여 홍삼 위치에 따라 부분 보정된 알고리즘을 개발하였다. 5) x-선관의 놓인 위치에 따라서 내공판정시험 결과 중심에 있을 때에 비해 가장자리에 있을 때는 영상이 일부 손실되었으며, 중심 위치에서 서로 다른 굵기의 홍삼에 대해서는 모두 양호한 결과가 나타났다. 6) 완전한 홈삼으로 내공판정시험 결과 내공주위의 정상부분가지도 일부 내공으로 잘못 검출되었으나 이것을 재차 line profile에 의해 한 라인씩 문턱 값을 설정하여 내공만을 정확하게 판정하는 알고리즘을 개발하였다.양체의 접종작업은 모든 배양실이 인력에 의존하였으며, 배양체를 배지와 분리하여 불필요한 부분을 제거하고 배양작물에 따라 생육정도를 2~3등급으로 구분하여 배양용기의 배지 위에 치상하는 과정으로 수행되었으며, 작업능률은 호접란의 경우 배양병에 25본을 접종하는데 시간당 6병, 심비디움은 원형 플라스크에 25본을 접종하는데 시간당 10병 정도였다. 바. 식물체의 대량증식에 사용되는 플라스크, 배양병, PE용기 등 배양용기의 세척작업은 농원의 1개배양실에서 간이식 세척기, 이 외의 9개배양실은 모두 물에 담겨 두었다가 세제와 브러쉬 등을 사용하여 인력으로 세척하고 있어 생력화 기술개발이 요구되었다.도가 빠를수록 건조속도가 빨라졌으며, 건조에너지도 1,334kcal/kg.water로 비슷하게 소요되었다. 마. 시험구와 대비구의 건감률은 시험구에서 1.08~1.36w.b./h로 나타나 대비구보다 약 9.9~18.3%가 높게 나타났고, 건조에너지는 10.2~14.6%가 절감되었다. 발아율은 열풍온도가 낮을수록 높게 나타났고 시험구가 대비구보다 발아율이 낮게 나타났으며, 동할률 증가량도 원적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성

  • PDF

An Analysis of the Environmental Benefits of the Price Signal Recovery under the Current Electricity Tariff in Korea (국내 계약종별 전기요금 체계의 가격신호 회복에 따른 환경편익 분석)

  • Jae Yeob Kim;Yeonjei Jung
    • Environmental and Resource Economics Review
    • /
    • v.31 no.4
    • /
    • pp.909-930
    • /
    • 2022
  • Although the electricity tariff for each customer class in Korea has an institutional basis which can be linked to cost fluctuations caused by the increase in fuel cost, there is a situation in which it cannot be raised in a timely manner, considering the national economic burden such as inflation. There can be some disagreements about unconditionally raising electricity rates when cost increases occur. It is, however, well known that Korean domestic electricity rates are very low around the world and are in an environment in which rates are not easily adjusted. Moreover, as Korean electricity rates cannot be easily raised due to various factors, domestic electricity rates for each customer class itself have not delivered a desirable price signal for power consumption. Based on historical data such as fuel costs and power production by power source from 2017 to 2020, this study estimated how much power consumption would change if electricity rates were adjusted in 2030 and price signal distortion was resolved. As a result of the estimation, power consumption will be reduced by 9,000 GWh if the current electricity bill is adjusted to a level which can be 100% recovered even with the supply cost alone. This led to a reduction of about 3.82 million CO2tons of greenhouse gas emissions in the Korean power sector.

Environmental Improvement Effect and Social Benefit of Environmental Impact Assessment: Focusing on Thermal Power Plant (환경영향평가를 통한 화력발전소의 환경개선 효과와 사회적 편익)

  • Kang, Eugene;Kim, Yumi;Moon, Nankyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.3
    • /
    • pp.322-333
    • /
    • 2018
  • This study was carried out to measure atmospheric environmental improvement effect and estimate its social benefit of thermal power plants through Environmental Impact Assessment (EIA) for quantitative analysis about operational performances of EIA. In this study, 'EIA outcome' is defined as whether or not the system is implemented, therefore, environmental standard to be followed by each project and consultation contents were compared. In total 60 cases of thermal power plant construction projects that have been consulted over the past 10 years since 2010, major air pollutants have been significantly reduced after the implementation of EIA. The $PM_{10}$ reduced annual 3,745 tons, $NO_2$ by 74,569 tons, and $SO_2$ by 37,647 tons, which were estimated at approximately 240 billion won~5 trillion 967 billion won per year for social benefit. This means the total cost of power plant operations will be cut to 7 trillion 192 billion won~178 trillion 994 billion won over a 30-year period. The reduced amount of air pollutants emitted by energy generation facilities across the country is worth 50%, and its economic value is larger than the annual Current Health Expenditure in Korea. This is meant by the fact that all projects are subject to uniform criteria under the existing relevant regulation, but that each project plans are optimized according to the characteristics of target areas and projects through the process of EIA.

Determination of Thermal Radiation Emissivity and Absorptivity of Thermal Screens for Greenhouse (온실 스크린의 장파복사 방사율 및 흡수율 결정)

  • Rafiq, Adeel;Na, Wook Ho;Rasheed, Adnan;Kim, Hyeon Tae;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.311-321
    • /
    • 2019
  • Greenhouse farmers often use thermal screens to reduce greenhouse heating expenses during the winter, and for shade during hot, sunny days in the summer, as it is an inexpensive solution to temperature control relative to other available options. However, accurate measurements of their emitted and absorbed radiations are important for the selection of suitable screens that offer maximum performance. Material's ability to save energy is highly dependent on these properties. Limited studies have investigated the measurement of these properties under natural conditions, but they are only applicable to materials having partial porosities. In this work, we describe a new radiation balance method for determining emissive power and absorptive capacity, as well as reflectivity, transmissivity and emissivity of materials having complete and partial transparency by using pyrgeometer and net radiometer. In this study, four materials with zero porosity, were tested. The emissivity value of PE, LD-13, LD-15 and PH-20 was $0.439{\pm}0.020$, $0.460{\pm}0.010$, $0.454{\pm}0.004$, and $0.499{\pm}0.006$, respectively. All tested samples showed high emitted radiation as compared to absorbed radiation.