• Title/Summary/Keyword: 에너지 성능 평가

Search Result 1,890, Processing Time 0.034 seconds

Design of Excess Flow Device for Automotive Cylinder Valve Based on Finite Element Analysis (유한요소 해석을 이용한 자동차 압력 용기 밸브용 과류 방지 장치의 설계)

  • Lee, Hyo-Ryeol;Kwon, Dae-Hwan;Shin, Jin-Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.19-29
    • /
    • 2021
  • Due to the climate changing, the world's countries are tightening regulations on CO2 and air pollutants emission to solve them. In addition, eco friendly vehicles is increasing to replace automobiles in internal combustion engine. Recently, the government is supporting the expansion of hydrogen refueling infrastructure and localization of core equipment in refueling facilities according to the hydrogen economy road map. In this study, design of the Excess flow limiting device in FCEV cylinder valve using by finite element analysis and performed performance tests on prototype. Major test results as hydrostatic strength, continued operation, operation, pressure impulse, leakage showed that the excess flow limiting device meets the performance requirements according to ISO 12619-2 and ISO 12619-11.

Packaging Standardization for Biological Control Agents (천적 곤충 포장 표준화에 관한 연구)

  • Ham, Eun Hye;Nam, Yun Bok;Jun, Hye Jeong
    • Korean journal of applied entomology
    • /
    • v.60 no.2
    • /
    • pp.203-214
    • /
    • 2021
  • This study aimed at establishing a packaging standardization method that allows the maintenance of biological control agents product quality during delivery. First, based on the results of distribution status analysis of biological control agent products from four manufacturers, we confirmed that the mean temperature was maintained at 25.6℃ (minimum and maximum temperatures.: 18.1 and 30.7℃, respectively) inside the packaging box of each company for 36-48 h. To establish the optimal packaging method for each season, seven external temperature conditions were set ranging between 0℃ and 30℃ at intervals of 5℃. In addition, we evaluated internal temperature maintenance performance for each coolant pack handling method and determined 14 packaging combinations. A packaging combination that maintained a temperature of 3℃ - 9.9℃ at each external temperature conditions was considered efficient. This temperature range is close to a lower developmental threshold at which the biological control agents can survive with minimum energy for 12 h (direct delivery time), or 36-48 h (general delivery time) after packaging.

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

Validating Dozer Productivity Computation Models (도저 생산성 연산모델 비교 연구)

  • Kim, Ryul-Hee;Park, Young-Jun;Lee, Dong-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.531-540
    • /
    • 2019
  • Existing dozer productivity computation models use different input variables, formulas, productivity correction factors, and experimental data source. This paper presents a method that characterizes the productivity outputs obtained by the PLS model and the Caterpillar model that are accepted as industry standards. The method identifies the input variables to be collected from the site, the performance charts to be referenced, and the formulas and implements them in a single computational tool. This study verifies that the PLS model may replace the manual computational process of Caterpillar model by eliminating reliance on graphics manipulation. Replacing the Caterpillar model with the PLS model and implementing the process as a function contributes to assess the productivity of a dozer timely by encouraging to utilize real-time information collected directly from the site. This study allows researchers and practitioners to effectively deal with the values of productivity correction factors collected from the job site and to control the productivity. The practicality and effectiveness of the method have been validated by applying to a project case.

The Operating Condition and Flow Field Design Effect on the Anode Water Management of a Proton Exchange Membrane Fuel Cell (PEMFC) (운전조건 및 유로형상에 따른 고체고분자형 연료전지의 수소극에서의 수분관리)

  • Hong, In Kwon;Kim, Sunhoe
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.518-521
    • /
    • 2011
  • A PEMFC single cell with the active area of $25cm^2$ was used to verify the effect of water management in the anode. Water management is one of the most critical operating variables. In this paper the effect of operating condition change, such as anode humidification and temperature, was investigated under constant current density of $200mA/cm^2$ where possible anode flooding operating area. Also experiments to observe the effect of the anode and cathode stoichiometry change and flow field design on the water management were performed. The water management was effected by the stoichimetry change. The temperature and humidification change also affected the fuel cell performance.

Preparation and Gas Permeation Characteristics of Polyetherimide Hollow Fiber Membrane for the Application of Hydrogen Separation (수소분리를 위한 Polyetherimide계 고분자 중공사막의 제조 및 기체투과 특성)

  • Kwon, Hyeon Woong;Im, Kwang Seop;Kim, Ji Hyeon;Kim, Seong Heon;Kim, Do Hyeong;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.31 no.6
    • /
    • pp.456-470
    • /
    • 2021
  • In this study, polyetherimide-based hollow fiber membranes were manufactured using the NIPS (nonsolvent induced phase separation) method. THF, Ethanol, and LiNO3 were used as additives to control the morphology of the PEI-hollow fiber membranes. Furthermore, for the development of a high hydrogen separation membrane, the spinning conditions were optimized through the characterization of SEM and gas permeance. As a result, as the content of THF increased, the hydrogen/carbon dioxide selectivity increased. However, the permeance decreased due to the trade-off relationship. When ethanol was added, a finger-like structure was shown, and when LiNO3 was added, a sponge structure was shown. In particular, in the case of a hollow fiber membrane with an optimized PDMS coating layer, the permeance was 40 GPU and the hydrogen/carbon dioxide selectivity was 5.6.

CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber (덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD)

  • Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2021
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. A curved constant temperature chamber was constructed that can be tested under the same conditions as in the natural state so that the research can be conducted in which frost does not occur on the outdoor unit of the heat pump regardless of the season. Simulations were performed to verity whether such a curved constant temperature chamber has feasibility as an experimental device. For CFD conditions, the length of the straight duct in front of the outdoor unit located in the duct-type constant temperature chamber was 1, 5, 10 and 15 times the diameter of the duct. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Development of a pipe burst detection model using large consumer's smart water meter and pressure data (대수용가 스마트미터와 수압 데이터를 이용한 소블록 내 관 파손사고 감지모델 개발)

  • Kyoung Pil Kim;Wan Sik Yu;Shin Uk Kang;Doo Yong Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.521-521
    • /
    • 2023
  • 지방상수도의 관 파손사고 감지 및 누수관리 방법에는 블록시스템 구축을 통한 소블록별 야간최소유량 감시방법이 가장 대표적이다. 야간최소유량은 새벽 2시와 4시 사이의 인구 활동 비율이 가장 낮은 새벽 시간대에 소블록에 공급된 유량을 의미하며, 대부분 유량 성분은 누수량일 것이라는 가정에서 출발한다. 그러나 아파트 중심의 주거 형태를 보이는 도심지의 경우, 새벽 시간대에도 다량의 물수요가 비정기적으로 발생하고 있어 관망의 이상 여부를 감시하기 위한 관리기준으로서 야간최소유량을 이용하기에는 높은 일간 변동성에 따른 한계가 있다고 할 수 있다. 즉, 야간최소유량은 관 파손사고 발생의 감시보다는 관로 연결 또는 급수전 분기 부위에서 발생하는 미량의 누수가 수개월에 걸쳐 누적되는 장기추세를 분석하여 누수탐사반의 투입 시점을 결정하기 위한 근거를 제시하기 위한 목적으로 사용되며, 아직까지 관 파손사고의 발생은 자체적인 감지보다는 민원에 의해 인지되는 경우가 많다. 최근, 스마트관망 구축사업(SWM) 등을 통해 관 파손 및 누수 감지를 위한 청음식 누수감지센서가 소블록 내 도입되고 있으나, 초기 시설투자에 큰 비용이 수반되며 주변 소음과 배터리 전원방식의 한계로 인하여 새벽 시간대에만 분석이 제한적으로 적용되는 경우가 많아 이 역시도 상시적인 관 파손사고의 감시기술이라 보기는 어렵다. 본 연구에서는 소블록 유입점에서의 유량·압력과 소블록 내에 설치된 대수용가 스마트미터, 그리고 사고감지를 위한 수압계 사이의 평상시 수리적 균형을 학습한 DNN(Deep Neural Network) 모델을 이용하여 관 파손사고를 실시간 감지하는 모델 개발연구를 수행하였다. 모델은 관 파손사고 감지를 위한 수압계의 최적 위치와 대수를 결정하기 위한 모듈과 관 파손사고 감지모듈로 구성되며, 1개 소블록 Test-Bed를 구축하여 모델을 생성하고 PDD 관망해석 모델을 통해 생성된 가상의 사고에 대한 감지 여부로서 개발 모델의 감지성능을 평가하였다.

  • PDF

Numerical Simulation of Standing Column Well Ground Heat Pump System Part 1: Validation of the Numerical Model (단일심정 지열히트펌프의 수치적 모델링 Part I: 수치해석 모델 검증)

  • Park, Du-Hee;Kim, Kwang-Kyun;Kwak, Dong-Yeop;Chang, Jae-Hoon;Park, Si-Sam
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.2
    • /
    • pp.33-43
    • /
    • 2010
  • Geothermal energy is gaining wide attention as a highly efficient renewable energy and being increasingly used for heating/cooling systems of buildings. The standing column well (SCW) is especially efficient, cost-effective, and suitable for Korean geological and hydrological conditions. However, a numerical model that simulates the SCW has not yet been developed and applied in Korea. This paper describes the development of the SCW numerical model using a finite-volume analysis program. The model, through hydro-thermal coupled analyses, simulates heat transfer through advection, convection, and conduction. The accuracy of the model was verified through comparisons with field data measured at SCWs in the U.S. and Korea. Comparisons indicated that the SCW numerical model can closely predict the performance of a SCW. The numerical model was used to perform a comprehensive parametric study in the companion paper.

Experimental Investigation on the Compression Behavior of Concrete Filled Circular FRP Tubes (콘크리트 충전 FRP 원통관의 압축거동에 관한 실험적 연구)

  • Joo, Hyung-Joong;Lee, Seung-Sik;Kim, Young-Ho;Park, Jong-Hwa;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.21 no.3
    • /
    • pp.24-30
    • /
    • 2008
  • Durability problems may arise in the concrete, which is one of the major construction materials, used in the construction field. Bridge piers and foundation piles are usually made with concrete and they are exposed to the moisture and hence the durability of the concrete reduced significantly due to oxidization of re-bar and icing of concrete. To mitigate such problems, FRP tube has been developed and the concrete filled FRP tube (CFFT) has been investigated to find the confinement effect which is provided additionally. It was reported that if the concrete is wrapped with FRP, strength and chemical resistance are improved significantly. In order to apply such a member in the construction field, structural behavior and applicable design guideline or design criteria must be thoroughly investigated. In the experimental investigation, the results are compared with the previous research results and the relationship which can predict the ultimate strength and strain is suggested. In addition, some comments found at the compression tests are given briefly.