• Title/Summary/Keyword: 에너지 및 연료 기술

Search Result 644, Processing Time 0.026 seconds

Preparation of flexible energy storage device based on reduced graphene oxide (rGO)/conductive polymer composite (환원된 그래핀 옥사이드/전도성 고분자 복합체를 이용한 플렉시블 에너지 저장 매체의 개발)

  • Jeong, Hyeon Taek;Cho, Jae Bong;Kim, Jang Hun;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.280-288
    • /
    • 2017
  • Nanocarbon base materials such as, graphene and graphene hybrid with high electrochemical performances have great deal of attention to investigate flexible, stretchable display and wearable electronics in order to develop portable and high efficient energy storage devices. Battery, fuel cell and supercapacitor are able to achieve those properties for flexible, stretchable and wearable electronics, especially the supercapacitor is a promise energy storage device due to their remarkable properties including high power and energy density, environment friendly, fast charge-discharge and high stability. In this study, we have fabricated flexible supercapacitor composed of graphene/conductive polymer composite which could improve its electrochemical performance. As a result, specific capacitance value of the flexible supercapacitor (unbent) was $198.5F\;g^{-1}$ which decreased to $128.3F\;g^{-1}$ (65% retention) after $500^{th}$ bending cycle.

SPACE DEBRIS의 전파방해(우주 쓰레기 종량제 입박)

  • 김광영
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.2
    • /
    • pp.54-58
    • /
    • 1995
  • 1957년 인공위성의 효시가 되는 스프티닉 1호 발사이래 1994년 현재까지 약 4,000회로 추정되는 각종통신 측지 첩보 및 실험 위성 등의 발사로 지구 적도상공 36,000Km의 정지궤도 이하의 공간에는 수많은 퇴역위성, 소아마비위성(부분기능고장위성)과 더불어 발사로켓트 상단의 위성 격납용기인 내연성의 훼 어링(Fairing)의 탈락파련(Fragment)등으로 혼재된 부유물은 약 4,000톤으로 예상되며 이중 95%가 쓸모 없는 우주 쓰레기에 해당된다고 보고 있다. 여기서, 우주쓰레기의 정의는 "현재와 장래에도 유용한 목적에 이용되지 못하는 인공물체"로서 크기 로는 10여미터로 부터 산화된 연료 분사개스의 수미크론의 분진으로까지 광범위하다. 그러나, 본고에서는 우주 활동에 악영향을 끼칠수 있는 대량으로 산재된 밀리미터에서 쎈티미터의 크 기의 고속 운동 에너지를 지닌 쓰레기 조각(Debris)을 고찰해 보고자 한다.

  • PDF

KISA 초대석 - 영원한 무재해 발전소로 기억될 것 - 한국중부발전(주) 서울화력발전소 박형구 소장

  • Im, Dong-Hui
    • The Safety technology
    • /
    • no.178
    • /
    • pp.24-25
    • /
    • 2012
  • 한국중부발전(주) 서울화력발전소는 당인리발전소로 잘 알려진 우리나라 최초의 화력발전소다. 제4호기(137,500kW)가 준공된 1971년 당시에는 서울시 전력수요의 75%를 담당하는 등 우리나라 산업발전의 견인차 역할을 해왔다. 현재는 제4, 5호기 총 설비용량 387,500kW로 수도권 전력 공급의 중추적인 역할을 해오고 있는 것은 물론, 국내 최초 열병합발전소로서 여의도, 동부이촌동, 반포, 마포 지역의 5만 여 세대에 난방열과 온수를 공급하고 있다. 이외에도 1993년부터는 발전연료로 사용해온 유류를 천연가스로 전환하고, 2002년에는 질소산화물 저감설비를 설치해 대기환경오염 수치를 10분의 1로 낮추는 등 에너지 절약 및 환경보전에 대한 노력도 꾸준히 펼치고 있다. 이와 같이 우리나라 최고의 화력발전소로서 명성을 이어온 이곳은 지난 1980년 11월 7일부터 무재해를 이어오면서 무재해 23배수와 무재해일수 11,591일이라는 대기록을 달성했다. 이는 무재해 운동을 벌이고 있는 기업들 중 최장의 무재해기록이기도 하다. 그렇다면 이곳은 어떤 활동을 통해 무재해 사업장의 명맥을 이어나갈 수 있었을까. 한국중부발전(주) 서울화력 발전소의 박형구 소장을 만나 이야기를 나눠봤다.

  • PDF

An Empirical Study of Hot Water Supply Patterns and Peak Time in Apartment Housing with District Heating System (공동주택의 급탕부하 지속시간 및 부하 패턴에 관한 실증연구)

  • Kim, Sung-Min;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.435-443
    • /
    • 2012
  • The combination of space shortage and the high population density concentrated in urban areas of South Korea has resulted in the growth of large-scale high-rise residential complexes, naturally affecting water and hot water usage patterns as well. But the current designs for water and hot water supply in South Korea rely mostly on international design standards and data calculated on site due to the severe shortage of basic data in relation to actual use, which result in the frequent problem of the under-or over-design of water and hot water supply. The following study measures the hot water supplier's conditions and the user's heat usage to realize the amount of time required for hot water supply load generation and the pattern of actual use in order to create basic data for effective hot water supply facility design and maintenance.

Development of Land Fill Gas(LFG)-MGT Power Generation and Green House Design Technology (쓰레기 매립지 MGT 발전 및 유리온실 설계기술개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2011
  • The high fuel flexibility of Micro Gas Turbine(MGT) has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and landfill as a fuel for gas turbines has increased. We researched the influence of firing landfill gas(LFG) on the performance and operating characteristics of a micro gas turbine combined heat and power system. $CH_4$ and $CO_2$ simultaneous recovery process has been developed for field plant scale to provide an isothermal, low operating cost method for carrying out the contaminants removal in Land Fill Gas(LFG) by liquid phase catalyst for introduce into the green house for the purpose of $CO_2$ rich cultivation of the plants. Methane purification and carbon dioxide stripping by muti panel autocirculation bubble lift column reactor utilizing Fe-EDTA was conducted for evaluate optimum conditions for land fill gas. Based on inflow rate of LFG as 0.207 $m^3$/min, 5.5 kg/$cm^2$, we designed reactor system for 70% $CH_4$ and 27% $CO_2$ gas introduce into MGT system with $H_2S$ 99% removal efficiency. A green house designed for four different carbon dioxide concentration from ambient air to 1500 ppm by utilizing the exhaust gas and hot water from MGT system.

Characteristics of Iodine Values and Viscosities by blending of Waste Vegetable Oil and Diesel Oil (폐식용유와 디젤유 블렌딩을 통한 요오드가 및 점도 특성)

  • Jeong, Dong-Seok;Nam, Byeong-Uk;Jeong, Yong-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1648-1653
    • /
    • 2009
  • Fossil fuel causes the greenhouse effect by emitting $CO_2$, and an estimated amount of oil deposits are also limited. Therefore, people have been interested in alternative energies. Vegetable oil which is one of the alternative energies is eco-friendly renewable energy source and has similar properties like diesel oil with high efficiency. Also, vegetable oil has been well recognized as one of solutions to reduce the greenhouse effect caused by $CO_2$release. In this study, we chose Waste vegetable oil(WVO) to solve the problems of high price of grain and lack of food. Impurities and sediments from WVO were removed by separation process using sieves of $15{\mu}m$pore size. Blending was performed in Homo-mixer by 5000 rpm for 10 min. We investigated viscosities and Iodine values in different compositions of WVO and diesel oil blends. Finally, we could find out blended oils have some possibility to be used in the diesel engine.

Technical Analysis on Existing Ship's Economical Operation (운항선 중심의 선박 경제운항 관리의 기술적 분석)

  • Kang, Nam-seon;Kim, Yong-dae;Yoon, Hyeon-kyu;Byeon, Sang-su
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.519-527
    • /
    • 2016
  • The present study is concept research on the operation cost management of shipping firms, especially considering technology for economical ship operation of existing ships in units of voyage. The factors that influence economical ship operation management were identified by analyzing the current status of the shipping industry, the development of economical ship operation technologies, technological requirements, and the cost factors of ship operation. Economical operation of existing ships, especially, the economical operation of the units of each voyage, may minimize fuel cost and port charges. This requires low-load streaming cruise control, ballast control, optimal trim, optimal routing, terminal work efficiency improvement, and ship energy management. Optimal routing and terminal work efficiency improvement manage the time saved. To determine the low-load streaming, cruise control, ballast control, optimal trim and ship energy management are meeting the recommendations.

Air-staging Effect for NOx Reduction in Circulating Fluidized Bed Combustion of Domestic Unused Biomass (국내 미이용 바이오매스 순환유동층 연소에서 NOx 저감을 위한 air-staging 효과)

  • Yoon, Sang-Hee;Beak, Geon-Uk;Moon, Ji-Hong;Jo, Sung-Ho;Park, Sung-Jin;Kim, Jae-Young;Seo, Myung-Won;Yoon, Sang-Jun;Yoon, Sung-Min;Lee, Jae-Goo;Kim, Joo-Sik;Mun, Tae-Young
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.127-137
    • /
    • 2021
  • Air emission charge for nitrogen oxide as a precursor of fine dust has been introduced and implemented within the country from 2020. Therefore, the development of economical combustion technology for NOx reduction has got more needed urgently. This study investigated the air-staging effect as a way to reduce the NOx during combustion of domestic unused forest biomass, recently possible to secure REC (Renewable Energy Certification) as a substitute for overseas wood pellets in a 0.1 MWth circulating fluidized bed combustion test-rig. Operating conditions were comparison with and without air-staging, the supply position of tertiary air (6.4 m, 8.1 m, 9.4 m in the combustor) and variation of air-staging ratio (Primary air:Secondary air:Tertiary air=91%:9%:0%, 82%:9%:9%, 73%:9%:18%). NO and CO concentrations in flue gas, profiles of temperature and pressure at the height of the combustion, unburned carbon in sampled fly ash and combustion efficiency on operating conditions were evaluated. As notable results, NO concentration with air-staging application under tertiary air supply at 9.4 m in the combustor reduced 100.7 ppm compared to 148.8 ppm without air-staging while, CO concentration increased from 52.2 ppm without air-staging to 99.8 ppm with air-staging. However, among air-staging runs, when tertiary air supply amount at 6.4 m in the combustor increased by air-staging ratio (Primary air:Secondary air:Tertiary air=73%:9%:18%), NO and CO concentrations decreased the lowest 90.8 ppm and 66.1 ppm, respectively. Furthermore, combustion efficiency at this condition was improved to 99.3%, higher than that (98.3%) of run without air-staging.

Portfolio Analysis on the New Power Generation Sources of the Sixth Basic Plan for Long Term Electricity Demand and Supply (포트폴리오 이론을 활용한 제6차 전력수급기본계획의 신규전원구성 비교 연구)

  • Kim, Juhan;Kim, Jinsoo
    • Environmental and Resource Economics Review
    • /
    • v.23 no.4
    • /
    • pp.583-615
    • /
    • 2014
  • Including the rolling black out in 2011, Korea has suffered from rapid increase of electricity consumption and demand forecasting failure for last five years. In addition, because of the Fukushima disaster, high fuel prices, and introduction of new generation sources such as renewables, the uncertainty on a power supply strategy increases. Consequently, a stable power supply becomes the new agenda and a revisino of strategy for new power generation sources is needed. In the light of this, we appraises the sixth basic plan for long term electricity demand and supply considering the changes of foreign and domestic conditions. We also simulate a strategy for the new power generation sources using a portfolio analysis method. As results, a diversity of power generation sources will increase and the share of renewable power generation will be surged on the assumptions of a cost reduction of renewable power sources and an increase of fuel costs. Particularly, on the range of a risk level(standard deviation) from 0.06 and 0.09, the efficient frontier has the most various power sources. Besides, the existing power plan is not efficient so that an improvement is needed. Lastly, the development of an electricity storage system and energy management system is necessary to make a stable and efficient power supply condition.

Process gas purification using cyclone recirculation and cooling process (싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구)

  • Kim, Ju-Hoe;Jo, Woo-Jin;Choi, Young-Tae;Jo, Young-Min;Kim, Sang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2018
  • Renewable energy has been of interests in the area of modern alternative fuels. Biogas is produced in waste landfill sites through anaerobic digestion processes, including hydrolysis, acidogenesis, organic acid fermentation (acetogenesis), and methane fermentation (methanogenesis). High contents of fine dust and moisture limited its utilization for direct combustion, town gas and vehicle fuel. Thus, this study proposed a new design for a cooling device using a centrifugal cyclone for simultaneous removal of fine dust and moisture as a pretreatment in the purification processes. A heat exchanger and an ID fan, which are installed inside and outside of the cyclone, in order to cool the humid gas below the freezing point and form a foggy mist. Such an atmosphere enhanced to capture fine dust as recirculating the cold mist flow. The water removal rate was 80.8% at a relative humidity of 95%, and the particle removal efficiency was 98.3% for $2.5{\mu}m$. Simultaneous removal efficiency was 70.8% and 99.6% for particle and moisture respectively.