• Title/Summary/Keyword: 에너지 기여도 평가

Search Result 1,107, Processing Time 0.03 seconds

Determination of Personnel Exposures in the Lower Energy Ranges of X-Ray by Photographic Dosimeter (저(低)에너지 X-선장(線場)에서 필름배지에 의한 개인피폭선량(個人被曝線量)의 결정(決定))

  • Ha, C.W.;Kim, J.R.;Suh, K.W.
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.57-64
    • /
    • 1986
  • This paper described an improved technical method required for proper evaluation of personnel exposures by means of the photographic dosimeter developed by KAERI in lower gamma or X-ray energy regions, with which response of the dosimeter varies significantly. With calibration of the dosimeter in the energy range from 30 to 300 keV, the beam spectrum was carefully selected and specified it adequately. The absorber combinations and absorber thickness used to obtain the specified X-ray spectra from a constant potential X-ray machine were determined theoretically and also experimentally. A correlation between the density and exposure for the four separate energies, such as $49\;keV_{eff},\;154\;keV_{eff}\;250\;keV_{eff}\;and\;662\;keV$, is experimentally determined. As a result, it can be directly evaluated the exposure from the measured response of dosimeter.

  • PDF

Monte Carlo Study of MOSFET Dosimeter Dose Correction Factors Considering Energy Spectrum of Radiation Field in a Steam Generator Channel Head (원전 증기발생기 수실 내 에너지 스펙트럼을 고려한 MOSFET 방사선검출기 선량보정인자 결정에 관한 몬테칼로 전산모사 연구)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • In Korea, a real-time effective dose measurement system is in development. The system uses 32 high-sensitivity MOSFET dosimeters to measure radiation doses at various organ locations in an anthropomorphic physical phantom. The MOSFET dosimeters are, however, mainly made of silicon and shows some degree of energy and angular dependence especially for low energy photons. This study determines the correction factors to correct for these dependences of the MOSFET dosimeters for accurate measurement of radiation doses at organ locations in the phantom. For this, first, the dose correction factors of MOSFET dosimeters were determined for the energy spectrum in the steam generator channel of the Kori Nuclear Power Plant Unit #1 by Monte Carlo simulations. Then, the results were compared with the dose correction factors from 0.652 MeV and 1.25 MeV mono-energetic photons. The difference of the dose correction factors were found very negligible $(\leq1.5%)$, which in general shows that the dose corrections factors determined from 0.662 MeV and 1.25 MeV can be in a steam general channel head of a nuclear power plant. The measured effective dose was generally found to decrease bit $\sim7%$ when we apply the dose correction factors.

A Study on the LCC Analysis of an Office Building HVAC System (오피스빌딩 냉난방시스템의 수명주기비용 분석에 관한 연구 : 흡수식 냉온수 유닛의 설치 유형을 중심으로 한 사례연구)

  • Park, Moon-Sun;Shin, Hyeong-Sik;Kim, Yong-Su
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.3 s.31
    • /
    • pp.112-121
    • /
    • 2006
  • The purpose of this study is to execute economical analysis for two types of office building HVAC system using LCC technique : single vs, separated HVAC(equal partition installation, unequal partition installation) system. The research method of this study includes the case analysis and questionnaire surveys. The results of this study are as follows: (1) LCCs of 3 types of HVAC system are estimated and the most economical one is investigated as single HVAC system, (2) In this case study, the single HVAC system was investigated as 34% lower in LCC during 15 years per $100m^2$ compared to equal partition installation, as 41% compared to unequal partition installation.

Development of Safety Climate Measuring Software Tool (안전문화측정 전산화 프로그램 개발)

  • Baek, Jong-Bae;Ko, Jae-Wook
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.63-68
    • /
    • 2009
  • The safety culture of an organization is very complex and hard to study, but it is possible to examine norms that make up the culture. This paper describes of a Process Safety Management (PSM) climate assessment tool developed in high risk industry such as chemical industries. The main purpose is to develop measuring software tool behaviors by examining their nature and strength and by analysing underlying factors that offer explanations for attitudinal differences. We reviewed the current techniques and literatures available to assess safety climate and culture, conducted focus group interviews and discussions. Based on the reviews and focus group, PSM climate assessment questionnaires and an online application program were developed. A pilot assessment was done at a chemical plant in Korea and the safety climate profile was completed. It was suggested to have a constant feedback from different sectors of industry to improve the application.

A Smart Damper Using Magnetic Friction And Precompressed Rubber Springs (자력 마찰과 기압축 고무 스프링을 이용한 스마트 댐퍼)

  • Choi, Eun Soo;Choi, Gyu Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.223-229
    • /
    • 2016
  • This study proposes a new technology for a smart damper with flag-shaped behavior using the combination of magnetic friction and rubber springs. The magnet provides friction and, thus, energy dissipation, and the rubber springs with precompression contribute to present self-centering capacity of the damper. To verify their performance, this study conducts dynamic tests of magnet frictional dampers and precompressed rubber springs. For the purpose, hexahedron Neodymium (NdFeB) magnets and polyurethane rubber cylinders are used. In the dynamic tests, loading frequency varies from 0.1 to 2.0 Hz. The magnets provide almost perfect rectangular behavior in force-deformation curve. The rubber springs are tested without or with precompression. The rubber springs show larger rigid force with increasing precompression. Lastly, this study discusses combination of rigid-elastic behavior and friction to generate 'flag-shaped' behavior for a smart damper and suggests how to combine the magnets and the rubber springs to obtain the flag-shaped behavior.

Evaluation of Adhesion, Hydrophobicity and Color Gamut of Nanoparticle embedded Polyurethane Topcoat for Aircraft with 3 Different Nanoparticles (항공기용 3종류 나노입자들로 함침된 폴리우레탄 탑코트의 접착성, 소수성 및 색재현성 특성평가)

  • Kim, Jong-Hyun;Kwon, Dong-Jun;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.22 no.1
    • /
    • pp.16-21
    • /
    • 2021
  • In the aircraft industry, anti- and de-icing are one of very important techniques for the safety. The anti-icing technique had not been studied while de-icing technique had been not only researched enough but applied to aircraft industry. In this work, surface roughness and energies of polyurethane (PU) topcoat were controlled with 3 different nanoparticles which was coated to PU topcoat. It was evaluated via static contact angle using distilled water. The adhesion property of 3 nanoparticles was evaluated directly using adhesion pull-off test. The color gamut of nanoparticle coated PU topcoat was also evaluated with 3 different nanoparticles. It was determined using RGB color degree variation between neat PU topcoat and coated nanoparticle. Finally, the optimized nanoparticle was determined to manufacture hydrophobic surface and to maintain color of neat PU topcoat for the aircraft.

Application of Flux Profile Method for Evaluating the Temperature Decreasing Effects of Green roof (여름철 옥상녹화의 온도저감효과 평가를 위한 Flux Profile Method의 적용)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.94-94
    • /
    • 2021
  • 현재 전 지구적으로 일어나고 있는 극단적 기후현상과 이로 인한 자연재해의 원인은 복합적이다. 기후변화로 인한 영향과 동시에 도시화 또한 하나의 원인으로 작용하고 있다. 이러한 영향을 완화하기 위한 방안으로 도시의 그린인프라와 저영향개발은 최근 지속가능한 발전을 위해 꼭 필요한 요소로 자리잡고 있다. 그린인프라 유형 중 하나인 옥상녹화는 많은 이점을 제공한다. 도시에 위치한 건물의 상층부, 내부 및 주변 온도을 낮춤으로써 얻을 수 있는 에너지절감 효과와 강우 시 상당량의 빗물을 저류함으로써 기대되는 우수유출 저감효과, 그리고 도시 공간 내 식물의 적극적인 도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 도시지역의 열섬현상완화와 유출저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 연직방향 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상자료를 Flux Profile Method를 적용하여 무강우기간과 강우발생기간 동안의 연직 방향의 현열속, 잠열속, 토양열속(H, LE, G) 을 산정하였다. 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 적용성을 평가하였다. 실험의 대조군인 일반 코팅재로 마감된 콘크리트 지붕의 무강우 기간 중 최대 현열속 693.82 W/m2 잠열속은 330.15 W/m2 으로 나타났으며, 실험군인 옥상녹화가 조성된 지붕의 최대 현열속 436.27 W/m2, 잠열속 949.20 W/m2 으로 나타났으며, 산정치와 관측치 시계열의 NSE는 0.81 으로 Flux Profile Method를 통해 산정된 열속의 정확도는 비교적 높은 것으로 나타났다. 이와 같은 방법으로 옥상녹화의 정량적 평가가 가능해짐으로써 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Analysis of Pure Refrigerant Cycle Design on C3MR Process through Driver Selection (동력 공급 장치 선택을 통한 C3MR 공정의 순수냉매 사이클 설계 분석)

  • Lee, Inkyu;Tak, Kyungjae;Lim, Wonsub;Moon, Il;Kim, Haksung;Choi, Kwangho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.27-32
    • /
    • 2013
  • Natural gas liquefaction process which is operated under cryogenic condition spends large amount of energy. Most of energy in the natural gas liquefaction process is consumed by compressors. Therefore, minimizing energy consumption of compressors is an important issue in process design and operation. Among various natural gas liquefaction processes, propane pre-cooled mixed refrigerant (C3MR) process consists of mixed refrigerant system and pure refrigerant system. In this study, to find the optimal design of pure refrigerant system, pure refrigerant cycle is simulated on different number of pressure levels and the necessary energy of each design is compared. After that, the driver selection model is applied to analyse each processes, which has different number of equipments, in terms of cost. As the result, the design using many equipments spends lower energy. Using this result, this study suggests standard of process design selection by the cost term.

An Investigation into the Building's Thermal Mass Effect on the Variation of Indoor Temperature (건물의 축열질량이 실내기온 변화에 미치는 영향 평가)

  • Chun, Won-Gee;Jeon, Myung-Seok
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.72-80
    • /
    • 1992
  • This paper is concerned with the accurate estimation of the thermal mass effect on the variation of indoor temperature for residential buildings. To carry out the analysis here, the method called "PSTAR(Primary and Secondary Terms Analysis and Renormalization)" has been extensively used. This method was originally developed by the National Renewable Energy Laboratory(NREL) in the United States. The test results reported here represent two extreme cases of the interior thermal mass, which demonstrate its effect on the interior thermal environment as well as on the overall thermal behavior of the building structure. The monthly heating and cooling loads are also extrapolated by using the renormalized model, which are crucial in designing and refurbishing HVAC systems for the building.

  • PDF

Performance Evaluation of Multi Effect Distillation for Solar Thermal Desalination (태양열 해수담수화를 위한 증발식 다중효용 담수기 성능평가)

  • Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.74-79
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3/day$ capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3/hour$ sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8m^3/hour$ for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3/day$ of fresh water. And, Performance ratio of Development Multi effect distillation was about 2.0191.

  • PDF