• Title/Summary/Keyword: 양성자단층촬영

Search Result 23, Processing Time 0.02 seconds

Development of a Proton Computed Tomography System with Monte Carlo Simulation (양성자 전산화 단층 촬영 장치 개발에 관한 전산모사 연구)

  • Seo, Jeong-Min;Kim, Chan-Hyeong
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.215-219
    • /
    • 2011
  • Monte Carlo simulation was performed to investigate optimal system of proton computed tomography and to avoid the errors by using data from X ray computed tomography in proton therapy. The informations from two DSSDs to measure position and LYSO scintillation detector to measure the residual energy of proton particle in GEANT4 were used for reconstruction computed tomography.

Stopping Power Ratio Estimation Method Based on Dual-energy Computed Tomography Denoising Images for Proton Radiotherapy Planning (양성자치료계획을 위한 이중에너지 전산화단층촬영 잡음 제거 영상 기반 저지능비 추정 방법)

  • Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.207-213
    • /
    • 2023
  • Computed tomography (CT) images are used as the basis for proton Bragg peak position estimation and treatment plan simulation. During the Hounsfield Unit (HU) based proton stopping power ratio (SPR) estimation, small differences in the patient's density and elemental composition lead to uncertainty in the Bragg peak positions along the path of the proton beam. In this study, we investigated the potential of dual-energy computed tomography image-based proton SPRs prediction accuracy to reduce the uncertainty of Bragg peak position prediction. Single- and dual-energy images of an electron density phantom (CIRS Model 062M electron density phantom, CIRS Inc., Norfolk, VA, USA) were acquired using a computed tomography system (Somatom Definition AS, Siemens Health Care, Forchheim, Germany) to estimate the SPRs of the proton beam. To validate the method, it was compared to the SPRs estimated from standard data provided by the National Institute of Standards and Technology (NIST). The results show that the dual-energy image-based method has the potential to improve accuracy in predicting the SPRs of proton beams, and it is expected that further improvements in predicting the position of the proton's Bragg peak will be possible if a wider variety of substitutes with different densities and elemental compositions of the human body are used to predict the SPRs.

Performance Evaluation of a Convolutional Neural Network Models for Diagnosing Malignant Pleural Effusion Using Positron Emission Tomography (양전자 단층 촬영 영상을 사용한 악성 흉수 진단을 위한 컨볼루션 신경망 기반 딥러닝 모델의 성능 평가)

  • Yeji Kim;Jong-Min Lee;Seung-Jin Yoo;Bo-Guen Kim;Hyun Lee;Yun Young Choi;Soo Jin Lee
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.17-18
    • /
    • 2024
  • 악성 흉수의 진단은 세포학적 검사로 암세포를 확인하는 것이 필수적이며 진단율은 50~80%로 나타난다. 양성자 단층 촬영은 비침습적으로 암 병기를 평가하는 유용한 방법이다. 하지만 암이 아닌 다른 원인으로 인한 포도당 대사로 인하여 양전자 단층 촬영만으로 악성 흉수를 진단하는 데 어려움이 있다. 악성 흉수 자동 진단 모델은 암세포를 진단하는데 있어서 보조적인 역할이 가능하다. 이에 따라 본 연구는 컨볼루션 신경망 기반의 딥러닝 모델을 개발하여 악성 흉수 진단 성능을 확인하고 진단의 보조적 목적으로써 딥러닝의 사용 가능성을 확인하고자 하였다. 결과적으로 모델 전반적으로 accuracy 0.7~0.86의 높은 성능을 보였다. 본 연구의 결과를 통해 실제 의료 환경에서 악성 흉수를 진단하는데 딥러닝 모델이 보조적인 역할을 할 수 있을 것으로 기대된다.

  • PDF

양성자 빔 조사중의 0-18 target의 상태변화에 대한 고찰

  • 허민구;오환섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.112-112
    • /
    • 2004
  • 양전자 단층촬영(PETㆍ Positron Emission Tomography)에 가장 널리 사용되는 방사성의약품인 FDG는 방사성동위원소인$^{18}$ F가 사용되며, 이는 안정물질인 H$_2$$^{18}$ O을 액체표적에 주입한 후, 고 에너지의 양성자빔을 조사하여 생산한다. 표적은 내화학성 및 높은 인장강도론 가진 재질인 titanium으로 제조하며, 0.075mm의 얇은 박판이 양성자빔 입사부에 사용된다. H$_2$$^{18}$ O가 주입된 표적에 양성자빔이 입사되는 순간 표적 내부는 높은 에너지로 인하여 표적물은 고온상태로 기화가 일어나고 이것이 압력을 증가시켜 target window는 바깥쪽으로 팽창한다.(중략)

  • PDF

Role of FDG-PET in the Diagnosis of Recurrence and Assessment of Therapeutic Response in Cervical Cancer and Ovarian Cancer Patients: Comparison of Diagnostic Report between PET, Abdominal a and Tumor Marker (자궁경부암 및 난소암 환자 재발진단과 치료반응평가에 있어서 FDG-PET의 역할: 양전자방출단층촬영, 복부전산화단층촬영 및 종양표지자 판독의 비교 분석)

  • Han, You-Mie;Choe, Jae-Gol;Kang, Bung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.201-208
    • /
    • 2008
  • Purpose: We aimed to assess the role of positron emission tomography using fluorodeoxyglucose (FDG-PET) in the diagnosis of recurrence or the assessment of therapeutic response in cervical and ovarian cancer patients through making a comparison between FDG-PET, abdominal computed tomography (CT) and serum tumor marker. Materials and methods: We included 103 cases (67 patients) performed FDG-PET and abdominal CT. There were 42 cervical cancers and 61 ovarian cancers. We retrospectively reviewed the interpretations of PET and CT images as well as the level of tumor marker. We calculated their sensitivity, specificity, positive predictive value and negative predictive value for these three modalities. And then we analyzed the differences between these three modalities. Results: Tumor recurrences were diagnosed in 37 cases (11 cervical cancers and 26 ovarian cancers). For PET, CT and tumor marker, in cervical cancer group, sensitivity was 100% (11/11), 54.5% (6/11) and 81.1% (9/11), respectively. And specificity was 93.6% (29/31), 93.6% (29/31) and 100% (31/31). In ovarian cancer group, sensitivity was 96.2% (25/26), 84.6% (22/26) and 80.8% (21/26), and specificity was 94.3% (33/35), 94.3% (33/35), 94.3% (33/35), PET was highly sensitive to detect the intraperitoneal and extraperitoneal metastasis with the help of the CT images to localize the lesions. However, CT had limitations in differentiation of the recurrent tumor from benign fibrotic tissue, identification of viable tumors at the interface of tissues, and detecting extraperitoneal lesions. Conclusion: FDG-PET can be an essential modality to detect the recurrent or residual tumors in gynecologic cancer patients because of its great field of the application and high sensitivity.

The Evaluation of Performance of C-11 Radio Isotope Gas Target using Finite Element Method (FEM을 이용한 C-11 동위원소 기체표적의 성능평가)

  • Oh, Hwan-Sup;Hur, Min-Goo;Park, Sang-Pil;Jung, Hyo-Jin
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.3
    • /
    • pp.24-31
    • /
    • 2006
  • The energy degrader is the most fragile part of the security of a target, has been newly designed to improve the performance of the gas target. Also, the numerical analysis of the heat movement and mechanical movement during the operation of the target has been accomplished. The heat analysis and structure analysis which are using the cooling water flow and pressure in the energy degrader and the finite element analysis program, has been considered with the heat movement and mechanical movement according to the current capacity of proton beam which determines the production yield of the radioactive isotope. Also the possible use range has been determined and at the same time the most suitable running condition according to the current capacity of proton beam has been suggested.

A Study of Conservative Treatment for Patients with Osteoarthritis of the TMJ (측두하악골관절염 환자의 보존적 치료에 관한 연구)

  • Son, Dae-Eun;Ok, Seung-Joon;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.227-239
    • /
    • 2007
  • To evaluate the treatment outcome after conservative treatment in patients with osteoarthritis of the TMJ(OA), the subjects were chosen among the patients who presented to the Department of Oral Medicine of Pusan National University Hospital, diagnosed as osteoarthritis of the TMJ, and treated with conservative methods from 1994 to 2006. 101 patients with diagnosis of osteoarthritis of the TMJ were selected as the experimental group and 74 patients with diagnosis of masticatory muscle disorders(MMD) were selected as the control group. Subjective symptoms and clinical findings were investigated to evaluate and compare the subject's status at the first and the last visit. The results were as follows : 1. In the OA group, satisfactory treatment outcome was obtained with conservative methods. But, at the last visit, the symptoms of the OA group were not improved enough compared with those of the MMD group. 2. In the OA group, radiographic findings of panorama view and transcranial projection were positive by about 60 percent. But, computed tomography and single photon emission computed tomography were positive by more than 90 percent. 3. At the last visit of the OA group, the joint noise was reduced significantly. 4. In the majority of the OA group, satisfactory treatment outcome was obtained with conservative methods such as medication, physical therapy, and occlusal stabilization appliance. In the majority of the MMD group, satisfactory outcome was obtained with medication and physical therapy. 5. It took the OA group from 6 months to 2 years to be cured well while the MMD group within 6 months.6. The OA group needed more than 10 times' treatment for satisfactory outcome while the MMD group needed less than 10 times' treatment.

Three Cases of Internal Jugular Phlebectasia (내경 정맥 확장증 3례)

  • Choi, Ic Sun;Son, Kyung Ran;Kim, Byung Ju;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.8
    • /
    • pp.1043-1047
    • /
    • 2002
  • Phlebectasia is an abnormal dilatation of an isolated vein and a rare venous anomaly and is usually asymptomatic. Clinically internal jugular phlebectasia is a self limited benign condition and usually no treatment is required after initial diagnosis. So suspection of this disease and appropriate diagnostic approaches are essential to avoid unnecessary surgical intervention. We present three cases of internal jugular phlebectasia of which diagnosis was made by neck sonography and CT.

Diagnostic Approach to a Soft Tissue Mass (연부조직 종양의 진단적 접근)

  • Chun, Young Soo;Song, Seung Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.293-301
    • /
    • 2019
  • Soft tissue masses of the extremities and torso are a common problem encountered by orthopaedic surgeons. Although these soft tissue masses are often benign, orthopaedic surgeons need to recognize the key features differentiating benign and malignant masses. An understanding of the epidemiology and clinical presentation of soft tissue masses is needed to develop a practical approach for evaluation and surgical management. Size and depth are the two most important factors on which triage decisions should be based. In a differential diagnosis of a tumor, it is important to know the characteristics of the soft tissue mass through detailed history taking and physical examinations before the diagnostic procedures. A variety of imaging studies, such as simple radiography, ultrasound, magnetic resonance imaging, positron emission tomography, computed tomography, bone scan, and angiography can be used to diagnose tumors. Know the ledge of advantages and disadvantages of each imaging study is essential for confirming the characteristics of the tumor that can be observed in the image. In particular, ultrasonography is convenient because it can be performed easily in an outpatient clinic and its cost is lower than other image studies. On the other hand, the accuracy of the test is affected by the skill of the examiner. A biopsy should be performed to confirm the tumor and be performed after all imaging studies have been done but before the final treatment of soft tissue tumors. When a biopsy is to be performed, careful attention to detail with respect to multidisciplinary coordination beforehand, cautious execution of the procedure to minimize complications, and expedient follow-up and referral to a musculoskeletal oncologist when appropriate, are essential.

Change of Proton Bragg Peak by Variation of Material Thickness in Head Phantom using Geant4 (Geant4 전산모사를 이용한 두개골 팬텀의 물질 두께 변동에 따른 양성자 브래그 피크의 위치 변화)

  • Kim, You Me;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.401-408
    • /
    • 2021
  • Proton therapy using the Bragg peak is one of the radiation therapies and can deliver its maximum energy to the tumor with giving least energy for normal tissue. A cross-sectional image of the human body taken with the computed tomography (CT) has been used for radiation therapy planning. The HU values change according to the tube voltage, which lead to the change in the boundary and thickness of the anatomical structure on the CT image. This study examined the changes in the Bragg peak of the brain region according to the thickness variation in the head phantom composed of several materials using the Geant4. In the phantom composed of a single material, the Bragg peak according to the type of media and the incident energy of the proton beams were calculated, and the reliability of Geant4 code was verified by the Bragg peak. The variation of the peak in the brain region was examined when each thickness of the head phantom was changed. When the thickness of the soft tissue was changed, there was no change in the peak position, and for the skin the change in the peak was small. The change of the peak position was mainly changed when the bone thickness. In particular, when the bone was changed only or the bone was changed together with other tissues, the amount of change in the peak position was the same. It is considered that measurement of the accurate bone thickness in CT images is one of the key factors in depth-dose distribution of the radiation therapy planning.