• Title/Summary/Keyword: 액체 물

Search Result 851, Processing Time 0.032 seconds

RGB-Depth Camera for Dynamic Measurement of Liquid Sloshing (RGB-Depth 카메라를 활용한 유체 표면의 거동 계측분석)

  • Kim, Junhee;Yoo, Sae-Woung;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.1
    • /
    • pp.29-35
    • /
    • 2019
  • In this paper, a low-cost dynamic measurement system using the RGB-depth camera, Microsoft $Kinect^{(R)}$ v2, is proposed for measuring time-varying free surface motion of liquid dampers used in building vibration mitigation. Various experimental studies are conducted consecutively: performance evaluation and validation of the $Kinect^{(R)}$ v2, real-time monitoring using the $Kinect^{(R)}$ v2 SDK(software development kits), point cloud acquisition of liquid free surface in the 3D space, comparison with the existing video sensing technology. Utilizing the proposed $Kinect^{(R)}$ v2-based measurement system in this study, dynamic behavior of liquid in a laboratory-scaled small tank under a wide frequency range of input excitation is experimentally analyzed.

Study on the Combustion Characteristics of Subscale Liquid Rocket Combustion Chamber (축소형 액체로켓엔진 연소기의 연소특성에 대한 연구)

  • Kim Jong-Gyu;Lee Kwang-Jin;Song Ju-Young;Moon Il-Yoon;Choi Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.288-293
    • /
    • 2006
  • The combustion performances and characteristics of the subscale liquid rocket combustion chamber are discussed in this paper. Subscale combustion chamber is composed of mixing head, ablative cooling cylinder, and water cooling nozzle. The mixing head has eighteen coaxial swirl injectors and one center coaxial swirl injector for ignition. The mixing heads employing the injectors of low different recess length are considered in this paper. The results of the firing test, comparison of performance, and characteristics of static and dynamic pressures of the four different mixing heads are described. The characteristics of combustion at design and of design points are also discussed.

  • PDF

Quality control for the liquid oxygen as the oxidizer of launcher and the liquid oxygen filling system as ground facility (액체산소를 사용하는 발사체 산화제 및 산화제 지상공급시스템의 품질관리)

  • Kim, Ji-Hoon;Yoo, Byung-Il;Kang, Sun-Il;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.309-312
    • /
    • 2009
  • The various hazards should be eliminated before operations for the successful launches or tests. Using the contaminated propellants is one of the causes for the launch and test failures. Especially, the systems using liquid oxygen as an oxidizer have risks about fires and explosions not be forecasted if they are contaminated by oil, water and mechanical impurities. The procedure for the quality control of the liquid oxygen and the liquid oxygen filling system and the lessons learned from the first launch preparation with the system are introduced on this paper.

  • PDF

Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure (실물크기 구조물에 설치된 동조액체질량감쇠기의 성능실험)

  • Heo, Jae-Sung;Park, Eun-Churn;Lee, Sang-Hyun;Lee, Sung-Kyung;Min, Kyung-Won;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Joo, Seok-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.449-457
    • /
    • 2008
  • In this paper, a tuned liquid1) mass damper(TLMD) was proposed and experimentally investigated on its control performance, which can control bi-axial responses of building structures by using only one device. The proposed TLMD controls the structural response in a specific one direction by using a liquid sloshing of TLCD. Also, the TLMD reduces the response of structures in the other orthogonal direction by behaving as a TMD that uses mass of the container itself and liquid within container of TLCD installed on linear motion guides. Force-vibration tests on a real-sized structure installed with the TLMD were performed to verify its independent behavior in two orthogonal directions. Test results showed that the responses of a structure were considerably reduced by using the proposed TLMD and its usefulness for structural control in two orthogonal directions.

  • PDF

Design of Flexible Liquid RFID Tag Antenna for attaching glass bottle (액체용기 부착을 위한 소형 플렉시블 특수태그 설계)

  • Yun, Jung-Mee;Ji, Sung-Hwan;Lee, Sang-Hak
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06d
    • /
    • pp.408-411
    • /
    • 2010
  • 본 논문에서는 의약품, 음료수병 등 액체용기에 부착이 가능하며, 주변 유전체에 의한 성능열화가 적고 소형으로 바코드를 대신하여 용기에 부착이 가능한 플렉시블 RFID 특수태그 안테나를 제안하였다. 제안된 태그 안테나는 PET 기판 위에 미앤더 기법으로 제작되어 제작 및 대량 생산에 용이하며, 범용 RFID의 사용주파수 (860~960MHz)를 만족시키고, 주변 유전물의 영향으로 인한 성능변화를 최소화할 수 있도록 설계하였다. 제안된 태그 안테나는 본체 중앙부에 T 정합회로를 사용하고 미앤더 구조와 직선 구조의 보조선로 2개를 본체 상단에 삽입하여, 캐패시티브 결합을 이용해 태그칩과의 임피던스 공액정합이 쉽게 이루어지도록 하였다. 또한 2개의 보조선로가 각각 다른 부착물체의 유전율에 상호 보완적으로 전류를 유기시 키도록 하여 주변 유전 물질의 영향에 의한 반사손실을 만족하도록 하였다. 본 태그의 성능은 송신출력 20dBm, 안테나 이득 6dBi인 리더 안테나를 사용하였을 때 자유공간에서는 3.5m, 유리 부착 시 2.61m, 액체가 든 유리병 부착 시 2.51m 의 인식거리 성능을 보였다.

  • PDF

The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in LN2 at the Atmospheric Pressure (대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상)

  • 박광서;신호영;최병주;박원주;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.49-55
    • /
    • 2003
  • This paper studied characteristics of surface discharge and tracking phenomena on the surface of solid insulators in Liquid Nitrogen(LN2) noticed as a cooling medium of high temperature superconductor. In order to investigate the bubble effect which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode were formed oppositely with A-mode, B-mode and C-mode configuration. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

Cold flow tests of Gas-centered swirl coaxial injectors (Gas-centered swirl coaxial 분사기의 상압수류시험)

  • Jeon, Jae-Hyoung;Hong, Moon-Geun;Kim, Jong-Gyu;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.16-19
    • /
    • 2011
  • An experimental study on the spray characteristics of Gas-centered swirl coaxial injectors(GCSCI) for high-performance staged combustion rocket engines has been carried out using cold flow tests. In this study, water and gaseous nitrogen are used as working fluids and a back-lit photography technique with image processing for the measurements of spray characteristics. Our study is focused on the effect of injector geometries like as gap thickness of liquid nozzle and gas nozzle and momentum flux ratio for fundamental understanding of the injectors.

  • PDF

Fluid Inclusions in Amethyst from the Korea Amethyst Deposit, Uljin, Gyeongbuk (경북 울진 코리아 광상의 자수정에 대한 유체포유물 연구)

  • Lee, Mi-Lyoung;Yang, Kyoung-Hee;Lee, Ju-Youn;Kim, Gyo-Tea
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.207-216
    • /
    • 2009
  • Three distinct types of fluid inclusions in amethyst and quartz crystals are associated with metamorphic events in the Korea Amethyst deposit from Uljin-Gun, Gyeongbuk Province. The amethyst displays bimodal grain size distribution in fine-grained, strain-free equigranular quartz with coarse-grained quartz grains with kink bands and undulose extinction. Type I inclusions are liquid-rich and salinity is 0~7 wt% NaCl and the homogenization temperatures ($T_h$) $91{\sim}231^{\circ}C$ with eutectic temperatures ($T_e$) $-52{\sim}-20^{\circ}C$. Type II inclusions are vapor-rich (80~90 vol%). The salinity and $T_h$ ranges 3~6 wt% NaCl and $230{\sim}278^{\circ}C$, respectively with $T_e$ $-56{\sim}-23^{\circ}C$. Type III inclusions contain a daughter mineral other than NaCl. The salinity ranges 32~36 wt% NaCl and $T_h$ $210{\sim}271^{\circ}C$. The textural and fluid inclusion evidences suggest that the host Buncheon granite gneiss and Amethyst pegmatite experienced dynamic recrystallization and the studied fluid inclusions are metamorphic in origin. The metamorphic event possibly occurred at higher temperature than $271{\sim}278^{\circ}C$. The amethysts from Uljin Korea Amethyst can be distinguished from the synthetic amethyst on basis of the distinctive two and three-phases fluid inclusions. Furthermore, it is noticeable that Korea amethyst do not contain NaCl-bearing and $CO_2$-rich fluid inclusions unlike those compared to those from Eonyang and Samcheonpo deposits related to unmetamorphosed granitic rocks.

A Study on Flammability Risk of Flammable Liquid Mixture (가연성 액체 혼합물의 인화 위험성에 관한 연구)

  • Kim, Ju Suk;Koh, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.701-711
    • /
    • 2020
  • Purpose: In this study, the risk of flammability of a liquid mixture was experimentally confirmed because the purpose of this study was to confirm the increase or decrease of the flammability risk in a mixture of two substances (combustible+combustible) and to present the risk of the mixture. Method: Flash point test method and result processing were tested based on KS M 2010-2008, a tag sealing test method used as a flash point test method for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was Japan's TANAKA. The flash point was measured with a test equipment that satisfies the test standards of KS M 2010 with equipment produced by the company, and LP gas was used as the ignition source and water as the cooling water. In addition, when measuring the flash point, the temperature of the cooling water was tested using cooling water of about 2℃. Results: First of all, in the case of flammable + combustible mixtures, there was little change in flash point if the flash point difference between the two substances was not large, and if the flash point difference between the two substances was low, the flash point tended to increase as the number of substances with high flash point increased. However, in the case of toluene and methanol, the flash point of the mixture was lower than that of the material with a lower flash point. Also, in the case of a paint thinner, it was not easy to predict the flash point of the material because it was composed of a mixture, but as a result of experimental measurement, it was measured between -24℃ and 7℃. Conclusion: The results of this study are to determine the risk of mixtures through experimental studies on flammable mixtures for the purpose of securing the effectiveness of the details of the criteria for determining dangerous goods in the existing dangerous goods safety management method and securing the reliability and reproducibility of the determination of dangerous goods Criteria have been presented, and reference data on experimental criteria for flammable liquids that are regulated in firefighting sites can be provided. In addition, if this study accumulates know-how on differences in test methods, it is expected that it can be used as a basis for research on risk assessment of dangerous goods and as a basis for research on dangerous goods determination.

Hydraulic Performance Test of a Turbopump (터보펌프의 수력 성능시험)

  • Hong Soon-Sam;Kim Dae-Jin;Kim Jin-Sun;Choi Chang-Ho;Kim Jinhan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.243-247
    • /
    • 2005
  • Hydraulic performance test was conducted for a fuel pump of a liquid rocket engine turbopump. The pump driven by an electric motor was tested in water environment. It is experimentally shown that the inducer had very small effect on the pimp's head and efficiency but great effect on the pump's cavitation performance. Additionally, inducer test was carried out to investigate the effect of the inducer on the pump in detail, and it was found that the pump had a critical cavitation number when the inducer head dropped by $55\%$.

  • PDF