• Title/Summary/Keyword: 액체섬광계수법

Search Result 14, Processing Time 0.033 seconds

Study on the Radiocarbon Dating with Liquid Scintillation Counting (액체섬광계수법을 이용한 방사성탄소 연대측정법 연구)

  • Kim, Nak Bae;Woo, Hyung Joo;Hong, Wan;Cho, Soo Young
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.381-387
    • /
    • 1992
  • Optimum counting condition of a low level liquid scintillation counter for radiocarbon dating has been determined to minimize the contribution of tritium activity and get the highest FOM by the variation of scintillation solutions, scintillation solution to benzene ratio, and ${\beta}$-ray spectrum counting ranges. Under the condition, background count rate has been reduced to $2.26{\pm}0.03cpm$, and the maximum measurable age reached to about 40,000 years. And the practicality of counting system has been verified by the analysis of shell and peat samples.

  • PDF

A Study on the Analysis of 89Sr and 90Sr with Cerenkov Radiation and Liquid Scintillation Counting Method (첼렌코프광과 액체섬광계수법을 이용한 89Sr 및 90Sr 분석에 대한 연구)

  • Lee, Myung-Ho;Chung, Geun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.20-25
    • /
    • 2002
  • An accurate and simple analytical technique for $^{89}Sr$ and $^{90}Sr$, overcoming the demerits of the conventional method, has been developed with extraction chromatography and liquid scintillation counting. The Sr fraction was separated from hindrance elements with oxalate coprecipitation or cation exchange resin and purified with Sr-Spec column. With liquid scintillation counter, $^{89}Sr$ was measured by Cerenkov radiation method, and $^{90}Sr$ was measured by spectrum unfolding method. The developed radioactive strontium separation method was validated by application to the IAEA-reference material (IAEA-375, Soil) and radioactive waste samples.

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Radioactivity Analysis of $^{55}Fe\;and\;^{63}Ni$ in Dismantled Concrete (해체 콘크리트 폐기물에 포함된 $^{55}Fe$$^{63}Ni$ 방사능 분석)

  • Kang, Mun-Ja;Chung, Kun-Ho;Hong, Sang-Bum;Choi, Geun-Sik;Lee, Chang-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Combined method of extraction chromatography and liquid scintillation analysis was established for determinating $^{55}Fe\;and\;^{63}Ni$ radioactivity in solid samples. Activated concrete wastes generated from dismantling KRR-2 were analysed. The sequential separation including precipitation and extraction chromatography resulted in the above 90% chemical recoveries of Fe. Above 62% recoveries of Ni were obtained by this procedure exception to 43.6 and 46.5% recoveries. The seperation and counting procedure was also confirmed with spiked samples of known quantity. The measured and spiked quantity were agreed with the 3.7% and 0.7% variations in the $^{55}Fe\;and\;^{63}Ni$ experiments, respectively. The radioactivities of $^{55}Fe$ in the dismantled concretes are shown from below MDA to maximum 362 Bq/g. The radioactivities of $^{63}Ni$ in all concrete samples are below MDA. The $^{63}Ni$ doesn't exist in dismantled concretes from KRR-2. The radioactivity of $^{55}Fe$ is decreased rapidly as the sampling depth is increased from the concrete surface.

  • PDF

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF

A Study of $^{222}Rn\;and\;^{226}Ra$ Analysis in the Groundwater by LSC (액체섬광계수기에 의한 지하수중의 $^{222}Rn$$^{226}Ra$ 분석법 연구)

  • Woo, Hyung-Joo;Yoon, Yoon-Yeol;Cho, Soo-Young;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1995
  • PERALS(Photon Electron Rejecting Alpha Liquid Scintillation) spectrometry coupled with solvent extraction method has been set up for the analysis of $^{222}Rn\;and\;^{226}Ra$ in the groundwater. This analytical method offers low background, better energy resolution and lower quenching problem than the other techniques. By the analysis of NIST SRM 4966 $^{226}Ra$ standard, the analytical accuracy and precision were found to be 3% and 1%, respectively, and the relative standard deviation of the recovery of Rn extraction between pH2 and pH10 was 7%. Detection limits of $^{222}Rn$ and $^{226}Ra$ for 10 hours counting were counted to be $0.42 pCi/{\iota}\;and\;0.016 pCi/{\iota}$, respectively. For the test analysis of $^{222}Rn\;and\;^{226}Ra$ in the graundwater, hot spring water samples of 17 regions were analyzed. The concentration of $^{222}Rn$ were in the range of $90{\sim}5200pCi/{\iota}$ and average value was $1470pCi/{\iota}\;^{226}Ra$ concentration showed a peak value of $97.9pCi/{\iota}$ in a Kangwon region, but the average value was $1.14pCi/{\iota}$ except that region.

  • PDF

Radiocarbon Dating Practices by Benzene Liquid Scintillation Method (벤젠-액체 섬광계수법에 의한 $^{14}C$ 연대측정)

  • Lee, Yeon-Gyu;Choi, Jeong-Min;Kim, Chang-Gyu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.3
    • /
    • pp.180-187
    • /
    • 1999
  • Radiocarbon dating method using benzene liquid scintillation was performed on the oyster shell fragments which producted from the shell mounts at Hadong Mogdori in Kyeongsangnamdo. This paper described to the age dating method and compared to the result. The carbon in sample is synthesized to a benzene through the sample preparation, $SrCO_3$, $SrC_2$, $C_2H_2$ and $C_6H_6$ synthesizing process. Age dating is calculated by Wallac 1415 Liquid Scintillation Counter. The result of age dating is estimated to be $4905{\pm}112$ yr BP in Yosu Univ. which is a good agreement with the result in Shimane Univ. ($4912{\pm}123$ yr BP). Radiocarbon dating method using benzene liquid scintillation is a simple and economical in operation and establishment, it has a potential instrumentation in the university and research institute.

  • PDF