• Title/Summary/Keyword: 액체렌즈

Search Result 29, Processing Time 0.025 seconds

Dynamics of Electrowetting of a Liquid-Liquid Interface in a Cylindrical Tube (원형관내의 액체-액체 계면에 대한 전기습윤 현상의 동적 거동)

  • Kang, Kwan-Hyoung;Chung, Won-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.557-560
    • /
    • 2006
  • The contact angle of a meniscus and a droplet can be controlled by using electrowetting phenomena. We investigated the dynamic aspect of electrowetting for an oil-electrolyte interface formed inside a closed glass tube. A step input voltage is applied and the subsequent motion of the interface is recorded by a high-speed camera. A kind of capillary instability is observed near the three-phase contact line, which could degrade the reliability of device utilizing electrowetting such as electrowetting liquid lens. The dynamics of interface motion for different input voltages and the fluid viscosities are analyzed and discussed based on the experimental results.

  • PDF

Simultaneous Determination of Both Surface Profiles of a Bifocal Lens Using Dual-Wavelength Transmission Deflectometry With Liquid (액체와 2 파장 투과형 편향법을 이용한 다초점 렌즈 양면 프로파일 동시측정)

  • Shin, Sanghoon;Yu, Younghun
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.147-154
    • /
    • 2015
  • We propose a method for simultaneously measuring the front and back surface profiles of transparent optical components. The proposed method combines dual-wavelength transmission deflectometry with liquids to record distorted phases at different wavelengths, and then numerically reconstructs the three-dimensional phase information to image the front and back surfaces of the lens. We propose a theoretical model to determine the surface information, and a bifocal lens is experimentally investigated. Unlike conventional transmission deflectometry, our proposed method supports direct observation of the front and back surface profiles of the optical elements.

Oxygen Diffusion According to the Fitting Conditions of Contact Lens (콘택트렌즈의 피팅조건에 따른 산소확산)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.35-43
    • /
    • 2008
  • Purpose: This review article was written to investigate how the various factors, such as lacrimal thickness, CL's thickness and Dk, affects the influx of $O_2$ diffusion into the cornea. Methods: A mathematical model was proposed to analyze the oxygen diffusion reaching the cornea through the tear layers and contact lens based on Fick's law and the principle of continuity of the diffusion flux through the each layers. Results: The model predicts how the parameters such as the thickness of tear layer on the cornea, both the Dk and thickness of contact lenses etc., affect the oxygen tension at cornea and oxygen flux entering the cornea. Conclusions: It is found that either too flat or too tightly fitted contact lenses can cause the oxygen deficiency at/inside the periphery of the cornea because of the reduction of oxygen flux resulted from too thickened tear layer.

  • PDF

Elution Properties of Naringin from Soft Contact Lens Containing Naringin (나린진(naringin)이 함유된 소프트 콘택트렌즈에서 나린진의 용출 특성)

  • Ryu, Geun-Chang;Jun, Jin;Jin, Moon-Seok;Chae, Soo-Chul;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: A soft contact lens was manufactured by adding naringin known as natural anti-bacterial material to resin solution. With solution eluted from manufactured contact lens, we examined its optical properties, physical and chemical states of naringin in the polymer, and elution properties. Methods: The soft contact lens with naringin was synthesized by bulk polymerization method. IR spectrum and HPLC were used to define the bonding type of naringin itself in the soft contact lens contained naringin, elution process of naringin to the saline solution, and the amount of naringin solution eluted from the lens with elapsed time. Results: Naringin was continuously eluted with constant concentration from the soft contact lens for about a month and the structure ofnaringin which is eluted was as same as before it was added to resin solution. Any change in optical properties such as transmittance couldn't be found. Bonding state and the structure of naringin in contact lens were explained with IR spectrum and HPLC results. Conclusions: In the contact lens with naringin, naringin remained in the contact lens bonding with weak hydrogen bonding and/or van der Waals force between naringin and polymer. Naringin was continuously eluted from the contact lens contained naringin during about 1 month. Even after 1 month, it showed that the concentration of the naringin eluted was approximately 10 ppm in a day. From the results, adding naringin to the soft contact lens resin is very effective method for manufacturing the soft contact lens which has anti-bacterial function for a period of time.

  • PDF

A Study on an Ultrasonic Transducer with a Spherical Liquid Lens (초음파 구면 액체 렌즈 변환기에 관한 해석)

  • 윤영중;박한규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.2
    • /
    • pp.22-28
    • /
    • 1993
  • In this paper, the ultrasonic transducer with a spherical liquid lens is designed and an efficient method to calculate the acoustic field radiated from the transducer is presented. A prototype ultrasonic transducer with a spherical liquid lens is constructed and tested. The experimental results are compared with those of the computer simulations and good agreements are achieved. The dynamic control of the geometric focus is obtained by adjusting the radius of curvature of the lens membrane with the volumetric control of the liquid in the lens.

  • PDF

Measurement of the Refractive Index of a Mixed Polymer by a Prism Spectrometer and its Application (프리즘 분광계를 이용한 혼합 폴리머의 굴절률 측정과 응용)

  • Kim, Ji-Young;Ju, Young-Gu
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.221-228
    • /
    • 2017
  • We measured the refractive index of a mixed polymer (NOA61, NOA84) in the liquid and solid states. First we made a hollow prism and filled it with UV (ultraviolet) epoxy. Measurement of the apex angle and the minimum-deviation angle gave the refractive index of the liquid polymer. To measure the refractive index of the solid polymer, an additional structure was included in the hollow prism, and the UV epoxy filling in the hollow prism was hardened. In both cases of liquid and solid polymers, the refractive index of the mixed polymer turned out to be proportional to the mix ratio. These results provide a method to vary the focal length of a double stacked cylindrical microlens array using UV epoxy.

Characterization of Electro-wetting Velocity by Measuring Transmission Intensity (광량 측정을 통한 전자습윤 현상의 동작 특성 평가)

  • Park, Seung-Ryong;Song, Seok-Ho;Oh, Cha-Hwan;Kim, Pill-Soo;Oh, Byoung-Do;Chung, Sang-Kug
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • The electro-wetting effect can be implemented as a fast means to move liquid interfaces. A continuous and numerical method would be required in measurement of electro-wetting liquid interfaces. We propose an /in-situ/ measurement method to characterize the dynamic change in curvature of liquid interfaces. In the proposed method, variation of light intensity transmitted through the liquid interfaces is measured, leading to numerical determination of the liquid curvatures. Experimental results obtained from our efficient method are confirmed by the direct images of a streak camera.

Effect of Injection Angle and Length to Diameter Ratios on Drop and Penetration Characteristics in Cross-flow (아름속 횡단 기체 유동장에서 노즐 형상 변화와 분사각 변화가 액적크기와 침투거리에 미치는 영향)

  • Lee, Bong-Soo;Ko, Jung-Bin;Cho, Woo-Jin;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.51-58
    • /
    • 2006
  • The spray characteristics of liquid jet injected into subsonic cross-flow were investigated experimentally. Spray trajectories were captured using CCD camera. Droplet sizes were measured using PDPA and Image Express. The nozzle diameter was 0.5 mm, and its length-to-diameter ratios (L/D) ran$4.11{\times}10^6$ged from 1.0 to 6.0. Experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration length is decreased by increasing Weber number. At low injection angle(${\theta}$ < $90^{\circ}$), Weber number is dominant parameter for trajectories, but at high injection angle(${\theta}$ > $90^{\circ}$), L/D is dominant parameter for trajectories rather than Weber number.

Dose Distribution of 100 MeV Proton Beams in KOMAC by using Liquid Organic Scintillator (액체 섬광체를 이용한 100 MeV 양성자 빔의 선량 분포 평가)

  • Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.621-626
    • /
    • 2017
  • In this paper, an optical dosimetric system for radiation dose measurement is developed and characterized for 100 MeV proton beams in KOMAC(Korea Multi-Purpose Accelerator Complex). The system consists of 10 wt% Ultima GoldTM liquid organic scintillator in the ethanol, a camera lens(50 mm / f1.8), and a high sensitivity CMOS(complementary metal-oxide-semiconductor) camera (ASI120MM, ZWO Co.). The FOV(field of view) of the system is designed to be 150 mm at a distance of 2 m. This system showed sufficient linearity in the range of 1~40 Gy for the 100 MeV proton beams in KOMAC. We also successfully got the percentage depth dose and the isodose curves of the 100 MeV proton beams from the captured images. Because the solvent is not a human tissue equivalent material, we can not directly measure the absorbed dose of the human body. Through this study, we have established the optical dosimetric procedure and propose a new volume dose assessment method.

A Study on an Ultrasonic Phased Array Transducer with a Spherical Liquid Lens (구면 액체 렌즈 초음파 위상 배역 변환기에 관한 연구)

  • 윤영중;박한규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.11
    • /
    • pp.9-16
    • /
    • 1995
  • In this paper, an ultrasonic phased array transducer with spherical liquid lens, which utilizes both electronic focusing by linear phased array and variable geometric focusing by spherical lens. is investigated. This system reduces the elevational beamwidth which is disadvantage of the 1-dimensional linear phased array, and adds real-time dynamic focusing capability by controlling the volume of liquid in the lens. A prototype of this transducer is constructed and tested. The experimental results are compared with those of computer simulations. The range of applications are in the hyperthermia applicators or ultrasonic image system with narrow beam and rapid scanning characterisitcs.

  • PDF