• Title/Summary/Keyword: 액면화재

Search Result 11, Processing Time 0.019 seconds

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.

Radiation Damage by the Pool Fire of LNG Storage Tank (LNG 저장 탱크의 Pool Fire에 의한 복사열 피해)

  • Sohn Jung-Hwan;Hahn Yoon-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.14-22
    • /
    • 1998
  • In this work, in order to quantitatively predict the radiation flux and propose an idea about how to reduce the radiation damage, the radiation flux caused by pool fire of an LNG storage tank has been calculated using the RISC (Risk and Industrial Safety Consultant) proposed model under various conditions. Model predictions showed that the most important parameter affecting the radiation flux by the LNG pool fire is the wind speed. The extent of radiation damage to a target from fire flame was more significant with variation of wind speed at a low wind speed than with that at a high wind speed. It was found that the radiation damage by the former is substantially reduced with planting windbreak system around the plant. Since the windbreak is most economical than any other method, it is strongly suggested to plant a tree belt in the factory surroundings, especially near by the area of gas storage facilities, linking with water cooling and fire protection systems.

  • PDF

A real scale test on performance of water spray systems in tunnel fire (터널화재시 물분무소화설비의 성능에 대한 실대시험)

  • Park, Kyung-Hwan;So, Soo-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.341-347
    • /
    • 2010
  • The performance of water spray system installed to reduce risks of tunnel fire is investigated by a real tunnel fire test. In case of A class fire, Pool fire, and car fire, the nozzle of water spray has had a marvelous effect to reduce the temperature of hot smoke. And it is verified to have remarkable cooling effects when there is the air flow in a tunnel. Though this results, water spray system will be able to prevent a fire jump to decrease the air temperature in a tunnel and to protect tunnel facilities by the fire control.

A Study on the Range of Damage Effects of Benzene Leakage Accidents using the KORA Program (KORA 프로그램을 활용한 벤젠 누출사고 피해영향범위에 관한 연구)

  • Cha, Jeong-Min
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.112-120
    • /
    • 2019
  • Benzene is a class 4 hazardous material according to the Act on the Safety Control of Hazardous Substances. This study qualitatively evaluated the damage size of a "toxic" accident and "pool fire" accidents based on benzene in a virtual scenario of a fire and leakage accident during unloading at a port facility. The KORA program was used as an evaluation method, which is supported as a universal program by the National Institute of Chemical Safety. The range of damage effects of a benzene-induced fire and leakage accident was predicted. In the case of toxic damage range, the accident's damage effect range for the "worst case scenario" was reduced by up to 5.11% with a decrease in the size of the leakage hole. In the case of the leakage time, the damage effect range increased to 145.12% with a 10 min leakage time compared to that of a 5 min leakage time and went up to 20 min (212.29%) with a 20 min leakage time. In the case of pool-fire-induced damage, the damage effect range by radiant heat in the "worst case scenario" was 228.8 m in radius from the center of the handling facility. In the "alternative scenario," the damage effect range by radiant heat was reduced by up to 8.26% compared to that in the "worst case scenario" since the size of the leakage hole was decreased by reducing the cross-sectional area of the pipe.

Measurements of Flame Temperature and Radiation Heat Flux from Pool Fire with Petroleum Diesel Fuel (디젤연료의 액면화재로부터 화염온도와 복사열 측정)

  • Lim, Woo-Sub;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.78-83
    • /
    • 2007
  • Diesel, a kind of petroleum, which is used in vehicles, vessels, boilers etc causes great damage when a fire happens, because it has higher caloric value than gasoline or kerosene has at burning. Therefore, pool fire experiment was carried using diesel which is sold on the gas station and radiation heat flux that occurs from flame and inner temperature of flame at burning was estimated. The maximum instantaneous flame temperature of diesel was more than $900^{\circ}C$, and the average of maximum flame temperature was $800^{\circ}C$ which occurred at 0.5 H/D distance from the surface of inflammable liquid, the distance has more long that has the lower the temperature of flame. In case of radiation heat flux, it grew to vary according to the size and amount of sample. When the size of a container for experiment was 0.5 m and sample layer was 13 mm and 20 mm, the radiant heat was 92.29 kW and 117.43 kW each. When the container was 1.0 m, it was 364.35 kW and 405.88 kW each.

가연성 2성분계 혼합물의 인화점

  • 하동명;목연수;최재욱;강호정
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.97-102
    • /
    • 1997
  • 공정상에서 가연성물질의 생산, 처리, 수송, 저장할 때 취급을 잘못하므로써 화재, 폭발 및 유해물질의 누출을 야기시킬 수 있다. 따라서 가연성물질의 안전한 취급을 위해서는 이들 물질의 중요한 기초적인 안전특성(safety property) 자료인 인화점(flash point)에 대한 지식을 필요로 하고 있다. 인화점은 가연성 액체의 화재 위험성을 나타내는 지표로써, 가연성액체의 액면 가까이서 인화할 때 필요한 증기를 발산하는 액체의 최저온도로 정의한다. 인화점에는 하부인화점과 상부인화점으로 나누고 있으며, 일반적으로 하부인화점을 인화점이라 한다. (중략)

  • PDF

유통법 장치를 이용한 Butylacetate와 2-Propanol계의 하부 및 상부 인화점

  • 하동명;최재욱;목연수
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.446-451
    • /
    • 2003
  • 인화점은 가연성 액체의 화재 위험성을 나타내는 지표로써, 가연성액체의 액면 가까이서 인화할 때 필요한 증기를 발산하는 액체의 최저온도로 정의한다. 인화점에는 하부인화점과 상부인화점으로 나누고 있으며, 일반적으로 하부인화점을 인화점이라 한다.(중략)

  • PDF

The Prediction of Lower Explosion Limit of n-Hexadecane (n-Hexadecane의 폭발하한계 예측)

  • Ha, Dong-Myeong;Park, Sang-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.163-163
    • /
    • 2013
  • 최근의 수많은 산업 현장에서 취급하고 있는 각종 화학물질은 잠재적 위험성이 크므로 보관, 수송 및 취급할 때 특별한 주의가 필요하다. 공정 설계 시 정확하지 않은 폭발한계를 사용함으로서 사고가 유발되는 경우가 많다. 따라서 사업장에서 사용되고 있는 화학물질의 화재 및 폭발 특성치인 인화점, 폭발한계 등을 정확히 파악하는 것은 중요하다. 인화점은 하부인화점과 상부인화점으로 나누고 있고 있으며, 인화점은 가연성 액체의 화재 위험성을 나타내는 지표로써, 가연성액체의 액면 가까이서 인화할 때 필요한 증기를 발산하는 액체의 최저온도 또는 점화원 존재시 인화가 일어날 수 있는 최저온도, 그리고 가연성증기의 포화증기압이 공기와 혼합기체의 폭발한계 하한농도와 같게 되는 온도로 정의한다. 폭발한계는 발화원이 존재할 때 가연성가스와 공기가 혼합하여 일정 농도범위 내에서만 연소가 이루어지는 혼합범위를 말한다. 본 연구에서는 실제 공정에서 사용되고 있는 n-Hexadecane의 인화점을 측정하여 이를 기존 문헌값과 비교 하였고, 측정된 인화점을 이용하여 폭발한계를 예측하였다. 예측된 폭발한계를 여러 문헌에 제시된 자료과 비교하여 공정안전에 타당한 자료를 제시하였다. 본 연구는 n-Hexadecane을 취급하는 공정에서 안전 확보의 중요한 지침 마련과 MSDS D/B의 최신화에 유용한 정보를 제공하는데 목적이 있다.

  • PDF

The Prediction of Flash point of Binary systems by Using Regression Analysis (회귀분석을 이용한 2성분계 인화점 예측)

  • Park, Sang-Hun;Lee, Myung-Ho;Cho, Young-Se;Na, Byoung-Gyun;Kim, Kyu-Hyun;Kim, Wan-Seop;Lee, Sung-Jin;Ha, Dong-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.41-41
    • /
    • 2013
  • 화학산업이 발달함에 따라 화학 산업 현장에서 사용되고 있는 가연성물질들의 여러 가지 화재 및 폭발 위험이 증가되고 있으며, 화재 및 폭발의 예방 안전을 위한 화학공정설계 및 대처에 있어, 물질의 연소특성치 데이터를 필요로 한다. 인화점은 가연성 액체를 다루는 공정에서 안전한 취급과 사고방지를 위해 중요한 자료가 되며, 화재의 위험을 나타내는 지표로서 가연성액체의 액면 가까이서 인화할 때 필요한 증기를 발산하는 액체의 최저온도, 그리고 가연성증기의 포화증기압이 공기와 혼합기체의 폭발한계 하한농도와 같게 되는 온도로 정의한다. 본 연구에서는 2성분계 혼합물에 대해 인화점을 측정하였고, 측정값을 Raoult의 법칙과 다중회귀분석(Multiple Regression)을 도입하여 이론값과 비교 하였다. 따라서 본 연구에서 제시된 방법론에 의해 아직까지 밝혀지지 않은 순수가연성액체와 가연성혼합물의 인화점을 예측하는 방법을 전개하고자 하며, 실험에서 찾고자하는 자료에 도움을 주고자 한다. 본 연구를 바탕으로 혼합물의 인화점 예측 방법과 실험에서 측정한 자료를 화재 및 폭발을 방지하는 기초 자료로 제공하고자하며, 산업현장에서 취급되고 있고 위험성 평가가 되지 않은 보다 많은 물질에 대한 이론 및 실험 연구에 활용 되도록 하는데 그 목적이 있다.

  • PDF