• Title/Summary/Keyword: 압력-시간 파형

Search Result 23, Processing Time 0.026 seconds

Experimental Investigation on Air Consumption and Pressure Wave Propagation inside A Filter Bag of A Dust Collector (집진기의 공기소모량과 백 필터내의 압력전파에 대한 실험적 연구)

  • Jeung, Won-Rark;Hong, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.886-891
    • /
    • 2008
  • This experimental investigation is concerned with the relationship between the electrical-on time of a solenoid which is located on the top of a pulse valve and air consumption of a dust collector. For the air consumption per pulse would be one of major factors affecting the operating cost of a dust collector, more attention is needed on the behaviour of a pulse valve. A pulse jet is blasted into a bag filter as the diaphragm valve opens and inflates a bag filter. This air-blast breaks up the dust layer and cleans the filter by dislodging dust cake. It is interpreted in this research that the cleaning filter is done by the impulse of a pulse jet. Hence, the magnitude and fluctuation of the dynamic pressure is measured using by a dynamic pressure sensor and the impulse is obtained by integrating dynamic pressure variation against time. Through this experimental work, conclusions are drawn implementing magnitude of averaged impulsive pressure per pulse or pressure impulse per unit volume of consumed air.

Evaluation of the Corroded Pipe by Time-Frequency Analysis (시간-주파수 해석에 의한 부식된 배관의 평가)

  • Ahn, S.H.;Kim, J.W.;Do, J.Y.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.89-92
    • /
    • 2006
  • In this study, the pressure vessel piping with corrosion used during long term were investigated from the time-frequency analysis method. The damage of piping could be evaluated the attenuation factor by ultrasonic parameters such as center frequency and echo waveform. Based on NDE analysis by time-frequency analysis method, it should also be possible to evaluate from various damages and defects in piping members.

  • PDF

Numerical Modeling of Wave-Type Turbulent Flow on a Stepped Weir (계단형 보에서의 파형 난류 흐름 수치모의)

  • Paik, Joongcheol;Lee, Nam-Ju;Yoon, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.575-583
    • /
    • 2017
  • Various types of flow patterns around the stepped weir and spillway, such as the skimming flow over such structures and the wave-type flow with a standing undular hydraulic jump and roller downstream of the structures, are developed in open channels. Unsteady three-dimensional numerical simulations are carried out using a hybrid RANS-LES turbulence modeling approach and the volume of fluid method for resolving free surface fluctuations to represent the turbulent flow including the skimming flow and wave-type flow over a stepped weir installed in a rectangular channel. The comparison of numerical results with an existing experimental measurement reveals that the present numerical simulations reasonably well reproduce the turbulent flow passing the stepped weir, in terms of time-averaged velocity profiles at selected locations downstream of the weir, flow topology characterized by the wave-type and skimming flows, the maximum height and length of the standing wave and the length of reattachment of recirculating zone. The numerical result further elucidates the distinct flow behaviors of the wave-type and skimming flow by presenting instantaneous intense variations of free surface and velocity vectors, the distributions of Reynolds shear stress and turbulent kinetic energy and three-dimensional complex features of coherent structures and total pressure distribution.

Poly-tetrafluoro-ethylene와 polyethylene 튜브 내부에 형성된 유전체 장벽 방전의 전류-전압 특성에 대한 연구

  • Jo, Yong-Gi;Choe, Yu-Ri
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.331.1-331.1
    • /
    • 2016
  • 내부지름이 2.0 mm 이하인 PTFE와 PE 튜브에 진공장치를 이용하여 튜브 내부의 압력을 감압하여 진공상태를 형성하였다. 진공기밀 후에 반응성 가스를 인입하여 튜브 외부에 장착된 전극을 통하여 고전압의 AC 전압을 인가하여 튜브 내부에 선택적으로 유전체 장벽 방전을 유도하였다. 본 연구에서는 유전율이 3.0 이하로 낮은 PTFE와 PE 튜브에 유전체 장벽방전이 유도될 때 나타나는 전압과 전류의 파형을 분석하여 방전의 개시와 방전의 형태를 조사하였다. 주파수 40 kHz인 AC 전원(PEII, Advanced Energy)과 Loadmatch 모듈을 이용하여 4 kV 이하의 전압을 인가하여 플라즈마 방전 유도하였다. 튜브에 인가고전압 프로브와 전류 프로브를 이용하여 오실로스코프를 I-V 분석을 실시하였고, 실험 결과 대기압 방전에서 유도되는 유전체 장벽방전의 I-V 특성과 달리 방전의 형태가 유전체장벽방전과 글로우방전이 혼합된 형태로 나타났다. 또한 유전체 장벽방전을 통해 튜브 내부에 형성되는 플라즈마에 대한 분석으로 OES 광분석을 실시하여, 방전 시간과 전압 변화에 따른 고분자 표면으로부터 방출되는 활성종에 대한 분석을 실시하였다.

  • PDF

Application of Acoustic Emission Technique and Friction Welding for Excavator Hose Nipple (굴삭기용 호스 니플의 마찰용접과 음향방출기법의 적용)

  • Kong, Yu-Sik;Lee, Jin-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.436-442
    • /
    • 2013
  • Friction welding is a very useful joining process to weld metals which have axially symmetric cross section. In this paper, the feasibility of industry application was determined by analyzing the mechanical properties of weld region for a specimen of tube-to-tube shape for excavator hose nipple with friction welding, and optimized welding variables were suggested. In order to accomplish this object, friction heating pressure and friction heating time were selected as the major process variables and the experiment was performed in three levels of each parameter. An acoustic emission(AE) technique was applied to evaluate the optimal friction welding conditions nondestructively. AE parameters of accumulative count and event were analyzed in terms of generating trend of AE signals across the full range of friction weld. The typical waveform and frequency spectrum of AE signals which is generated by friction weld were discussed. From this study the optimal welding variables could be suggested as rotating speed of 1300 rpm, friction heating pressure of 15 MPa, and friction heating time of 10 sec. AE event was a useful parameter to estimate the tensile strength of tube-to tube specimen with friction weld.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

Suction Pressures with respect to the Operational Modes using the Multi-bore Capillary Membranes in the Membrane Bioreactor (생물막 반응기내 다공성 중공사형막을 이용한 운전방식에 따른 흡입 압력)

  • Kim, Min Hyeong;Koo, Eeung Mo;Lee, Min Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.343-350
    • /
    • 2021
  • In this study the suction pressure was measured with respect to operational time by submersing the multi-bore capillary membrane module in membrane bioreactor(MBR). The hexagonal shape capillary module which has the nominal pore size of 0.2 ㎛, outer diameter of 6.4 or 4.2 mm was immersed in MLSS 8,000 mg/L active sludge aqueous solution, and confirmed changes with respect to permeation flux and air flow rate. It was operated by the filtration/relaxation(FR), FR with backwashing(FR/BW), and sinusoidal flux continuous operation(SFCO) modes. The suction pressure for the SFCO and FR modes was lower at 30 and 50 L/m2·hr, respectively. In addition, the suction pressure of the module with a small outer diameter was relatively low. The suction pressure of a large outer diameter was greatly increased, but it could be reduced by more than 40% by backwashing.

The three-dimensional temporal behavior measurement of light emitted from plasma display panel by the Scanned Point-Detecting System (Scanned Point-Detecting System을 이용한 플라즈마 디스플레이 패널에서 방출되는 광의 3차원 시간 분해 측정)

  • 최훈영;이석현;이승걸;김준엽
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.559-563
    • /
    • 2002
  • We measure the 3-dimensional temporal behavior of the light emitted from the discharge cell of a plasma display panel (PDP) by using a scanned point detecting system. The light signal detected by a PM tube is sent to the oscilloscope, and the oscilloscope is connected to a PC with GPIB. From the resultant temporal behaviors, we could analyze the discharge characteristics of the panel with a Ne-Xe (4%) mixing gas at a 400 torr pressure. The top view of the panel shows that discharge moves from the inner edge of the cathode electrode to the outer cathode electrode, forming an arc shape. The side view of the panel shows that the light is detected up to 150 $\mu\textrm{m}$ up the barrier rib. After a trigger pulse is applied, peak intensity is detected at 730 ns and peak intensity position is located at the center of the ITO electrodes.

Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS (가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성)

  • 이복희;이경옥;이창준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • This paper deals with the dielectric characteristics of $SF_6$ gas gap stressed by $\pm$1.2/44[$mutextrm{s}$] non-oscillating impulse and $\pm$0.4[$mutextrm{s}$]/1.14[MHz] oscillating impulse voltages in the presence of a needle-shape metallic particle in gas-insulated switchgear(GIS). Breakdown voltage-time (V-t) and breakdown voltage-gas pressure (V-p) characteristics were investigated and discussed. The experiments were carried out under highly inhomogeneous field geometry with a needle protrusion whose length and radius are 10[mm] and 0.5[mm], respectively. The gas pressure ranges from 0.1 to 0.5[㎫]. As a result, it was found that the electrical breakdown for both the positive and negative polarity develops with steplike pulses in leader mechanism, When subjected to the positive oscillating impulse voltage, the minimum breakdown voltages appeared in all the gas pressure ranges and the V-t curves have a pronounced upturning at short times to breakdown and give a little dependence of the gas pressure. On the other hand, in the case of the negative polarity the dependence of the V-t and V-p characteristics on the wave shape of the applied voltages is known to be appreciable.

  • PDF

Extraction of Parameters for Acupoint Discrimination and Design of discrimination system (경혈식별을 위한 파라메터 추출 및 식별시스템의 설계)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.89-101
    • /
    • 2001
  • The conventional pattern-methods for discrimination of acupoint, meridian line which is the basic object of diagnosis and medical treatment in oriental medicine is discriminated the conduction point by the stimulation in body skin with DC. But, it is not sufficient to truth in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper is extracting the optimal parameter of frequency and waveform in order to improve the conventional pattern, and proposing the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, this algorithm proposes to be able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It is able to decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. It is compared the performance of system applying the extracted optimal parameter and algorithm, and it is confirmed that there is difference in discrimination parameter of acupoint reacted to the individual and the meridian. It is compared that discrimination, coincident ratio of the traditional acupoints as the acupoint stimulation pattern. It is confirmed truth of optimal parameter and discrimination algorithm. Keyword: Meridian, Discrimination, Coincident, Body effect, Reproductivity, SPAC, Optimal parameter.

  • PDF