• Title/Summary/Keyword: 압력게이지

Search Result 68, Processing Time 0.023 seconds

Development of the Deflection Measuring System by Pressure Gage for a Floating Dock (압력게이지를 이용한 부유식 도크의 변형 계측시스템 개발)

  • Kim, Youngbok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.90-95
    • /
    • 2017
  • In case of working for the construction of blocks of any ship in a floating dry dock, there may exist deflection in the pontoon deck of the floating dock due to the ballast loading and the self weight of the ship and the floating dock. This paper is on the development of the measuring system and the GUI program to show the real time variation of the deflections at even-spaced positions by several pressure gages and the calculated inclination of the floating dock. The measured and calculated data produced by this developed system could be used to prepare the protection plan on site like ballast adjustment to ensure the safety of working during the floating dock operation.

Fabrication of a micromachined ceramic thin-film type pressure sensor for high overpressure tolerance and Its characteristics (과부하 방지용 마이크로머시닝 세라믹 박막형 압력센서의 제작과 그 특성)

  • Kim, Jae-Min;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.199-204
    • /
    • 2003
  • This paper describes on the fabrication and characteristics of a ceramic thin-film pressure sensor based on Ta-N strain-gauges for harsh environment applications. The Ta-N thin-film strain-gauges are sputter-deposited onto a micromachined Si diaphragms with buried cavity for overpressure protectors. The proposed device takes advantages of the good mechanical properties of single-crystalline Si as diaphragms fabricated by SDB and electrochemical etch-stop technology, and in order to extend the operating temperature range, it incorporates relatively the high resistance, stability and gauge factor of Ta-N thin-films. The fabricated pressure sensor presents a low temperature coefficient of resistance, high-sensitivity, low non-linearity and excellent temperature stability. The sensitivity is $1.097-1.21\;mV/V{\codt}kgf/cm^2$ in the temperature range of $25-200^{\circ}C$ and the maximum non-linearity is 0.43%FS.

Effect of Hot Pressing Conditions in Fabrication of Membrane & Electrode Assembly for Proton Exchange Membrane Fuel Cell (고분자 전해질형 연료전지에서 막-전극 어셈블리 제조지 Hot-pressing조건에 대한 영향)

  • 최경환;이승재;설용건;이태희;노용우;고영태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.23-27
    • /
    • 1994
  • 고분자 전해질형 연료전지의 성능을 향상시키기 위하여 막-전극 어셈블리 제조시 hot-pressing 온도와 압력조건을 변화시켜며 단위전지 성능을 관찰하였으며 이에 대한 분석은 열무게분석법(TGA), 기공도, 이온투과계수 등을 사용하였다. 또한 전지의 작동온도 및 압력을 변화시켜가며 전지의 성능을 관찰하였다. 성능 실험은 가습기의 온도와 cell의 온도, 압력을 변화시켜가며 측정하였다.

  • PDF

A Study of Non-uniform Pressure Distribution in Vacuum Chamber during Dynamic Gas Flow (기체유입이 되는 진공챔버 안의 불균등한 압력분포 연구)

  • Khan, Wakil;Hong, K.S.;Hong, S.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.403-410
    • /
    • 2009
  • Vacuum chambers have wide application for a variety of purposes such as material processing, vacuum gauge calibration, etc. As the dynamic pressure generated in such chamber is non-uniform, in many industrial as well as research processes, it is vital to know the non-uniform gas distribution with associated gas flow regimes and the ways of minimizing these pressure non-uniformities. In the present work, the behavior of gas flow in a vacuum chamber, during continuous gas flow, is described in the pressure range 0.1-133 Pa and the effect of baffle plate in minimizing the pressure non-uniformities is investigated. It was observed that maximum deviations in the pressure occur near the gas inlet point and that the effect of baffle plate in minimizing the pressure non-uniformities is more obvious in the transitional flow regime.

Inter-comparison between ultrasonic interferometer manometer and medium vacuum standards by static expansion method (초음파간섭 수은주압력계와 정적법 중진공 국가표준기 상호비교)

  • Hong S. S.;Lim I. T.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.103-109
    • /
    • 2005
  • A new medium vacuum primary standard using the static expansion method was developed in KRISS. In order to evaluate the performance of the equipment, we compared the medium vacuum standard with an ultrasonic interferometer manometer using two capacitance diaphragm gauges, the measuring ranges of which were 133 Pa and 1,333 Pa respectively. The result, Error normalized values, showed that the two standards are coincident each other within the range of combined uncertainty at calibrated pressure of $3pa\;\sim\;100pa$.

On the Prediction of Inner Pressure for the Tank in Rolling Motion (동요하는 탱크의 내부 변동압력 추정에 관한 연구)

  • Lee, Seung-Keon;Sea, Young-seok
    • Journal of Navigation and Port Research
    • /
    • v.27 no.5
    • /
    • pp.459-464
    • /
    • 2003
  • The inner liquid pressure of an airtight tank in rolling motions is investigated by means of forced oscillation tests, and the simple method to estimate the inner liquid pressure is proposed. A rectangular solid tank, which is fully filled with water, was used in the forced oscillation test of rolling motion. The inner pressure variations in time were measured at several points on the inner walls of tank. Measured pressures are compared with the calculated ones, and estimation methods of the inner liquid pressure of the tank in rolling motion are studied based on the considerations of the origin of pressure.

A Study on Effects of Revised High Heeled Shoes on Foot Pressure and Static Balance during Standing in Young Female (젊은 여성에서 수정보완된 하이힐이 서 있는 자세에서 족부압력과 정적균형에 미치는 영향에 관한 연구)

  • Bae, Young-Hyeon;Ko, Man-Soo;Park, Young-Soul
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.367-368
    • /
    • 2014
  • 본 연구는 전통적 하이힐과 수정보완된 하이힐 착용 시 간에 서있는 자세에서 족부압력과 정적균형을 비교하여 수정보완된 하이힐이 서 있는 자세에 미치는 영향을 알아보고자 하였다. 여대생 15명을 대상으로 하루 간격을 두고 동일한 대상에게 전통적 하이힐과 수정보완된 하이힐을 각각 착용하게 한 후 족부압력과 정적균형을 측정하여 비교 분석하였다. 그 결과, 수정보완된 하이힐의 족부압력은 전통적 하이힐보다 전족부는 유의하게 감소하고 후족부는 유의하게 증가하였다. 그리고 정적균형 능력은 전통적 하이힐보다 개선되었으나 유의하지 않았다. 따라서 수정보완된 하이힐이 전통적 하이힐보다 좀 더 정상적인 족부 압력을 가지게하고 그에 따라 균형능력에도 긍정적인 영향을 보일 것으로 생각된다.

  • PDF

First-Person Shooter Player Analysis System Based on Biometrics (생체 정보 기반 1인칭 슈팅 게임 플레이어 분석 시스템)

  • Kim, Dong-Gyun;Bae, Byung-Chull;Kang, Shin-Jin
    • Journal of Korea Game Society
    • /
    • v.17 no.6
    • /
    • pp.29-38
    • /
    • 2017
  • Predicting the user's reaction to the game at the stage of developing the game is important because it is related to the popularity of the game. In this paper, we propose a system that can collect and analyze game user's biometric information in a non-invasive way. To this end, we developed a mouse with skin conductance, pressure, gyroscope, and accelerometer sensor using Arduino. In order to verify the usefulness of this system, the subject was experimented with playing the first person shooter game with this mouse. We analyzed the gameplay videos recorded during Blizzard's 'OverWatch' and the bio-information collected from various sensors in the mouse.

정전 분체 도장관의 공기압력에 의한 미세분진의 마찰대전특성에 관한 연구

  • ;;N. Iwai;T. Kashiwazaki;M. Takeuchi;;M. Yamaguma;T. Kodama
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.327-332
    • /
    • 2000
  • 현대에 들어와 석유화학, 제약, 플라스틱 공업 등의 발달에 의해 분진의 기능이 활성화되었다. 그에 따라, 분진의 정전기 대전 현상으로 장·재해도 증가하고 있는 추세에 있다 공기 압력을 이용한 분체 도장의 경우는 물론이고, 일정구간으로 분진을 이송, 저장할 경우, 분진 입자는 배관 또는 입자 상호간 마찰, 충돌 등으로 전하의 이동 현상을 일으켜 대전된다[1]. 게다가, 단면적이 작은 개구부, 배관의 균열 등에 의해 일시적으로 외부로 분출되어질 때 대전량은 급상승하게 된다[2].(중략)

  • PDF

Achievement of a $10^{-11}$ Torr Ultrahigh Vacuum System ($10^{-11}$Torr의 초고진공 실현)

  • 유운종;이재선;김명길;서성기
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.28-31
    • /
    • 1992
  • 초고진공 시스템을 구성할 때 고려할 요소는 진공용기의 세척과 표면조도, 진공용 기의 재질, 기타 방출기체의 요인이다. 초고진공용기를 전해연마 처리하였으며, 처리한 진공 용기의 표면조도를 표면 조도기(surface profiler)로 측정하였다. 진공용기는 직경 300mm이 고 높이는 720mm로 하였다. 설치한 초냉각 펌프로 18시간 배기후 2.9 $\times$ 10-10Torr를 얻었 으며, 계속해서 초고진공용기를 250에서 60시간 baking 후 최저도달 압력이 3.08 $\times$ 10-11torr에 도달하였다 누드 이온게이지를 이용하여 초고진공용기의 최저도달압력과 누출비 를 측정하였다.

  • PDF