• Title/Summary/Keyword: 알루미늄 응집

Search Result 98, Processing Time 0.027 seconds

Application of Sulfuric Acid for Improving Coagulation Efficiency on the Down Stream of Nakdong River (낙동강 하류 원수의 응집효율 개선을 위한 황산의 적용)

  • Ryu, Dong-Chun;Bae, Eun-Young;Kim, Sang-Goo;Son, Hee-Jong;Song, Mi-Jeong;Kim, Young-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.2059-2065
    • /
    • 2000
  • The purpose of this study is to improve coagulation efficiency by pre-treatment of high pH water using sulfuric acid. The common reason of pH increasing at down stream of Nakdong river is water blooming. The pH go above 9.0 during water blooming periods. The higher pH water demands more coagulant and pre-chlorine dosage than lower pH water for better coagulation condition. The DOC, THMFP, UV-254 after coagulation with the same coagulant dosage by pre-treatment from pH 9.2 down to 8.1 with sulfuric acid are 1.84mg/L, $51{\mu}g/L$ and $0.032cm^{-1}$, by pretreatment of chlorine are 2.09mg/L, $78{\mu}g/L$ and $0.030cm^{-1}$, by pre-treatment of sulfuric acid and chlorine are 2.14mg/L, $72{\mu}g/L$ and $0.031cm^{-1}$ respectively. Pretreatment with sulfuric acid can improve water quality and reduce coagulant demand.

  • PDF

Optimization of Synthesis Condition and Determination of Residue for Polyamine Type Flocculant (폴리아민계 고분자 응집제의 합성조건 최적화 및 잔류물분석)

  • Choi, Soo-Young;Park, Lee-Soon;Im, Sung-Hyun;Ryoo, Jae-Jeong;Choi, Sang-June;Hwang, Won-Joo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1043-1046
    • /
    • 1998
  • Aluminium based inorganic flocculants are extensively used in this country in the removal of fine particles present in the raw water for the production of drinking water. These inorganic flocculants, however, have potential hazard of high residual aluminium ions in the treated waters, which is known to be one of the reasons of alzheimer's disease. Inorganic flocculants alone are sometimes incapable of treating water when there are excessive turbidity in the raw water sources due to flooding. A polyamine type polymeric flocculant has long been used to treat raw water in the drinking water production in the European countries and United State of America. The optimum reaction conditions such as mole ratio of epichlorohydrin(EPI) to dimethylamine(DMA), reaction temperature and time for each stage for the pilot scale preparation of polyamine from EPI-DMA was studied in this work. The variation of intrinsic viscosity and flocculating efficiency in the water treatment of the synthesized polyamines were evaluated. The residual materials after polymerization reaction were analyzed by gas chromatography to study the effect of variation of reaction conditions.

  • PDF

Removal of Rhodamine B using Electrocoagulation Process (전기응집 공정을 이용한 Rhodamine B의 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1081-1088
    • /
    • 2009
  • The performance of a electrocoagulation (EC) process was examined for the removal of Rhodamine B (RhB) using iron electrode. The effects of operational parameters such as electrode material (aluminum and iron), current density, NaCl dosage, intial pH and initial dye concentration on RhB removal efficiency were investigated. The optimum range for each of these operating variables were experimentally determined. The experimental results showed that the iron is superior to aluminum as sacrificial electrode material. The optimum time of electrolysis, current density, NaCl dosage and pH were 10 min, 1630 A/$m^2$, 4 g/L and neutral pH, respectively. Under these conditions, RhB was effectively removed (> 93.4%) and also more than 80% of COD was removed (> 88.9%) when the initial concentration of RhB was 230 mg/L. The electrical energy consumption in the above conditions for the color and COD of RhB removal were 10.3 and 10.8 kWh/kg RhB, respectively. The electrocoagulation process could be a promising technology to treat dye wastewater containing RhB.

Explosion Properties of Nano and Micro-sized Aluminium Particles (나노 및 마이크로 입자 알루미늄의 폭발 특성)

  • Han, Ou-Sup;Lee, Keun-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.20-25
    • /
    • 2014
  • Explosion characteristics of micro-sized aluminum dusts had been studied by many researchers, but the research of nano-sized aluminum dusts were very insufficient. In this study, an experimental investigation was carried out on the influences of nano and micro-sized aluminum dusts (70 nm, 100 nm, $6{\mu}m$, $15{\mu}m$) on dust explosion properties of aluminum particles by using 20 L explosion apparatus. With decreasing of particle size in suspended aluminum dusts, the LEC (lower explosion concentration) of nano-sized aluminum is lower than that of micro-sized aluminum. The particle size change of nano-sized aluminum dusts seems no obvious explosion differences than that of micro-sized aluminum dusts. From the observation of nano-sized aluminum particles by TEM (Transmission Electron Microscopy), it is estimated that increase of particles aggregation may have effects on the explosion characteristics of aluminum nanopowders.

Phosphorus Removal from Municipal Wastewater Using Ti-based Coagulants (티타늄계열응집제를 이용한 하수 내 인 제거)

  • Shin, So-Yeon;Kim, Jong-Ho;Ahn, Johng-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.428-434
    • /
    • 2016
  • This study evaluated the efficacy of Ti-based coagulants on phosphorus (P) removal from municipal wastewater and compared them with Al-based coagulants. Jar test experiments were performed at various chemical doses and OH/Ti molar ratio (B value). The higher the intial phosphate ($PO_4-P$) concentration, the lower the [Ti]/[P] to reach a residual concentration below 0.2 mg P/L. Removal efficiencies of total phosphorus increased with an increased coagulant dose but decreased after the efficiencies reached their maximum value regardless of coagulant or B value. On the other hand, $PO_4-P$ removal showed an increasing trend with an increased coagulant dose, reaching the plateau value under large coagulant dose conditions for both Ti- and Al-based coagulants regardless of B value. The chemical dose of Ti-based coagulants was approximately twice higher than that of Al-based coagulants with the same P-removal efficiency. The coagulation efficiency was influenced by different B values.

Comparison of Al(III) and Fe(III) Coagulants for Improving Coagulation Effectiveness in Water Treatment (정수처리 응집효율 개선을 위한 Al(III)염과 Fe(III)염 응집제의 비교)

  • Han, Seung woo;Kang, Lim seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.6
    • /
    • pp.325-331
    • /
    • 2015
  • The experimental results of the characteristics of aluminum based and ferric based coagulants for the Nakdong River water showed that the main hydrolysis species contained in alum and $FeCl_3$ are monomeric species of 98% and 93.3%, respectively. The PACl of r=1.2 produced by the addition of base contained 31.2% of polymeric Al species and the PACl of r=2.2 contained 85.0% of polymeric Al species, as showing more polymeric Al species with increasing r value. Coagulation tests using Al(III) and Fe(III) salts coagulants for the Nakdong River water showed that the coagulation effectiveness of turbidity and organic matter was high in the order of $FeCl_3$ > PACl (r=2.2) > PACl (r=1.2) > alum. $FeCl_3$ has showed better flocculation efficiency than Al(III) salts coagulants. In addition, in case of Al(III) coagulants, the Al(III) coagulants of higher basicity, which contained more polymeric Al species, resulted in better coagulation efficiency for both turbidity and organic matter removed. The optimum pH range for all of the coagulants investigated was around pH 7.0 under the experimental pH range of 4.0~9.5. Especially, the highest basicity PACl (r=2.2) and $FeCl_3$ were considered as more appropriate coagulants for the removal of turbidity in the case of raw water exhibiting higher pH.

Removal of Color from a Biological Piggery Wastewater Treatment Effluent by Chemical Coagulation (화학적 응집을 이용한 생물학적 돈분폐수 처리수의 색도제거)

  • Park, Noh-Back;Seo, Tae-Kyeong;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1047-1053
    • /
    • 2008
  • This study was to evaluate the optimum conditions for chemical coagulation to remove color from the effluent of a piggery wastewater treatment process. The DOC concentration in the effluent was about 227.3 mg/L, color was 2,430 CU, turbidity was 22.1 NTU, and UV$_{254}$-absorbance was 3.7 cm$^{-1}$. The fractions of hydrophobic, transphilic, and hydrophilic substance of the effluent was about 55.3%, 17.4%, 27.3% respectively. Also, molecular weight cut-off(MWCO) of below 0.5 K, 0.5 K to 1 K, 1 K to 10 K, 10 K to 30 K, and over 30 K were 74.2%, 7.3%, 5.5%, 7.1%, and 5.9% respectively. SCD(streaming current Detector) was used to find out the optimum pH values and coagulant dosages. The optimum dosages and pH of Al$^{3+}$ were 5.84 mM and 5.3, while those of Fe$^{3+}$ were 9.25 mM and 5.0, respectively. At optimum conditions of coagulation, color removal efficiencies for aluminium sulfate and ferric chloride were as high as 91.9 and 98.7%, respectively. Chemical coagulation showed good performance to remove color from on biologically treated piggery wastewater.

Effects of Dual-Coagulant Performance (이중응집이 응집공정에 미치는 영향)

  • Kim, Hee-Geun;Moon, Byung-Hyun;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This research is to investigate the effect of the dual coagulant using inorganic coagulants($AICl3{\cdot}6H2O$) and polymer on the coagulant process. Jar-test was conducted by using Kaolin injected raw water. PDA(Photometric Dispersion Analyzer) equipment in order to analyze the size of the particles and the characteristics of the shapes. The change in the rate of sample ores' residual deposited after coagulants were also compared. According to the result derived from this experiment, the concentration of inorganic coagulant reduced 50% and the residual was lower by using dual coagulants compared to using single coagulant. However the dual coagulant required sufficient mixing time, and affected particle characteristics, with the effect of the injection order of coagulants, the simultaneous injection of inorganic coagulant and polymer showed the most effective in the particle removal.

정수처리에 있어서 한외여과막의 Fouling에관한 연구

  • 김충환
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.18-21
    • /
    • 1995
  • 막분리에 의한 정수처리에서는 재래식의 응집, 침전, 여과공정을 대신하는 고액분리공정으로서 이용되고 있다. 이러한 막분리를 이용한 정수처리에는 한외여과막 및 정밀여막이 주로 이용되고 있으며, 이러한 막을 이용하므로써 원수중의 고분자성유기물질, 콜로이드물질등을 제거할수 있다. 그러나 미량유기물질과 같은 저분자성물질은 한외여과 및 정밀여과같은 정도의 배제 크기를 가지는 막으로는 분리할수 없다. 따라서 한외여과막 및 정밀여과막으로 분리할수없는 물질들은 역삼투막을 이용하고 있다. 이러한 막을 이용하므로써 응집제의 절약, 부지면적의 절감, 무인운전 및 응집제를 이용하지 않으므로써 알루미늄에의해 기인하는 치매병을 방지할수 있는등 여러가지의 장점이 있다. 특히 분리막을 이용한 정수처리는 프랑스, 미국, 일본 등을 중심으로 연구 개발되었다.

  • PDF

Effects of Aluminum Oxide Particles on the Erosion of Nozzle Liner for Solid Rocket Motors (고체 추진기관에서 산화알루미늄 입자가 노즐 내열재의 삭마에 미치는 영향)

  • 황기영;임유진;함희철
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.95-103
    • /
    • 2006
  • The compositions, the gas properties in motor chamber and the aluminum oxide (Al2O3) particle size for two kinds of solid propellants with approximately 20% aluminum powder have been investigated. The SEM photographs of $Al_2O_3$ taken from nozzle entrance liner show that the aluminized PCP propellant with 47% volumetric fraction AP/HNIW and bimodal oxidizer 200-5 ${\mu}m$ can offer greater possibility for increasing aluminum agglomeration than the aluminized HTPB propellant with 64% volumetric fraction AP and trimodal oxidizer 400-200-6 ${\mu}m$. The nozzle entrance liner of solid rocket motor with the PCP propellant shows greater erosion at 4 circumferential sections in line with grain slots due to the impingement of large particles, but that with the HTPB propellant shows uniform erosion with circumferential angle.