• Title/Summary/Keyword: 안축장길이

Search Result 5, Processing Time 0.023 seconds

Analysis on Ocular Components Variation with the Difference of Both Refractive Errors (양안 굴절이상 차이에 의한 안광학상수 변화도 분석)

  • Lee, Hae-Jung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.435-440
    • /
    • 2016
  • The aim of study was to provide the preliminary data to find out characteristics of the difference between both refractive errors through analysis of ocular components variation. We measured spherical equivalent power and corneal radius with KR-8800, and axial length and anterior chamber depth with IOL Master, and the difference of measuring values between the right eye and left eye was applied as the absolute values in 100 adults aged 20~59 years. In all participants, the most common results showed that spherical equivalent power was $-1.83{\pm}2.17D$, axial length was 23.00~24.99mm, corneal radius was 7.50~7.89mm, and anterior chamber depth was 3.60~4.09mm. There are significant correlations between both eyes in axial length and anterior chamber depth with the difference of both spherical equivalent power. The difference of both axial lengths was the biggest with the difference of both refractive errors, and shown the highest correlation. The convergence complex study through classification by aspects is needed since the difference of both refractive errors is closely related with ocular components variation, and poor visual function would be caused by the difference of both refractive errors.

The Study on Accommodation for eyes with pseudo-crystalline lenses (인공수정체안의 조절반응에 관한 연구)

  • Lee, Seok-Ju;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.203-209
    • /
    • 2004
  • Physiological accommodation in aphakia has been reported 0.50D. Also, accommodation appears in pseudo-crystalline lens. However accommodation was not clear how to works in the eyes. Therefore, the purpose of this study is that accommodation has been affected to changes of axial length and corneal refractive power when the accommodative stimulus was taken 10 diopters to person who has pseudo-crystalline lens. To determine of the accommodative response of pseudo-phakic patients who had no side effects over 2 months, we have measured the axial length, corneal refractive power in 48 patients(96 eyes). When the accommodative stimulus was taken about 10 diopters, the axial length increased by $0.05{\pm}0.06mm$ and corneal refractive power increased $0.04{\pm}0.24$ diopter. The changes of axial length in the myopia was increased by $0.19{\pm}0.18D$, emmetropia was increased by $0.12{\pm}0.16D$ and hyperopia was $0.10{\pm}0.19D$. The results of measurement revealed that the mean value was increased $0.03{\pm}0.13D$ in the myopia, and increased $0.21{\pm}0.13D$ in the emmetropia, and decreased $0.02{\pm}0.34D$ in the hyperopia.

  • PDF

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

Study of the Axial Length/Corneal Radius Ratio in Determining the Refractive State of the Eye (굴절이상과 안축장/각막곡률반경 비와의 관계에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.23-31
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.

  • PDF

Study of Correlation between Macular Thickness, Retina Nerve Fiber Layer Thickness and Axial Length according to Refractive Errors in Children (아동들의 굴절이상에 따른 안축장과 황반두께, 망막신경섬유층 두께의 상관성연구)

  • Choi, Hyung-Seok;Leem, Hyun-Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.421-429
    • /
    • 2018
  • Purpose : We identified correlation between macular thickness and RNFL (retina nerve fiber layer) measured by OCT and axial length in Korean children divided as three groups according to refractive errors. Methods : In total, 134 eyes of 67 Korean children who experienced no eye disease and ophthalmology surgery were involved in this study and then divided as three groups such as hyperopic, emmetropic and myopic groups. Macular thickness and RNFL thickness were measured with Cirrus HD-OCT, and axial length was done with IOL Master.Macular thickness and RNFL thickness were measured by Cirrus HD-OCT, and axial length using IOL Master. Correlation between axial length and retinal thickness in three groups according to refractive errors was investigated. Results : The type of refractive error measured by axial length was myopic, emmetropic and hyperopic groups in order, showing significant difference (p<0.05). The center thickness of macular was myopic, emmetropic and hyperopic groups in order, showing significant difference(p<0.05). The thicknesses of superior, nasal and inferior regions in peripheral macula were the thinnest in myopic group (p<0.05). It was shown that positive correlation was found between the center thickness of macula and axial length (r=0.283, p<0.05), while negative correlation was found between the peripheral thickness of RNFL and axial length. The temporal thickness of RNFL represented the thickest in myopic group, showing positive correlation with axial length(r=0.39, p<0.05). The superior, nasal and inferior thickness of RNFL represented negative correlation with axial length, showing statistically significant in the nasal thickness of RNFL(r=-0.23, p<0.05). Conclusion : Through this study, we identified correlation between macular thickness, the thickness of RNFL and axial length using OCT in Korean children, and also found the differences in three refractive error groups.