• Title/Summary/Keyword: 안정장비

Search Result 885, Processing Time 0.035 seconds

[Retracted]Cyber Threat Analysis on Network Communication in Power System and Countermeasures Suggestions ([논문철회]전력계통 네트워크 통신방식 변화에 따른 사이버위협 분석 및 대응방안 제시)

  • Il Hwan Ji;Seungho Jeon;Jung Taek Seo
    • Smart Media Journal
    • /
    • v.12 no.2
    • /
    • pp.91-102
    • /
    • 2023
  • The Energy Management System (EMS) communicates with power plants and substations, monitors the substations and plant operational status of the transmission and substation system for stability, continuity, real-time, and economy of power supply, and controls power plants and substations. Currently, the power exchange EMS communicates with power plants and substations based on the serial communication-based Distributed Network Protocol (DNP) 3.0 protocol. However, problems such as the difficulty of supply and demand of serial communication equipment and the lack of installation space for serial ports and modems are raised due to the continuous increase in new facilities to perform communication, including renewable power generation facilities. Therefore, this paper presents a TCP/IP-based communication method instead of the existing serial communication method of the power exchange EMS, and presents a security risk analysis that may occur due to changes in the communication method and a countermeasure to the security risk.

Bearing Capacity Evaluation of Marine Clay Dredged Deposit Including Desiccated Crust Layer (건조 고결층이 형성된 준설 매립 지반의 지지력 산정에 대한 연구)

  • Park, Hyun-Ku;Byeon, Wi-Yong;Jee, Sung-Hyun;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.89-100
    • /
    • 2007
  • In this study, various field and laboratory tests were performed to investigate the characteristics of shear strength and bearing behavior to be considered in the estimation of stability and trafficability in early stage of stabilization process in marine clay dredged deposit. Site characterization was carried out to grasp the basic properties of the deposit. Field vane test, unconfined compression test and direct shear test were conducted to evaluate the shear strength distribution for varied depths, and the characteristics of shear strength and stress-strain behavior of the crust layer. Plate load tests were also performed to estimate the bearing capacity and to assess load-settlement behavior and failure pattern of the deposit. The bearing capacity was also estimated using previously proposed methods for double-layered clay deposit. The estimated bearing capacity was compared with the results of the plate load tests and then, the applicability of the estimation method was discussed.

Strength of Improved Soil on the Work-conditions of Deep Mixing Method (시공조건에 따른 심층혼합처리 개량체의 강도에 관한 연구)

  • Lee, Kwang-Yeol;Yoon, Sung-Tai;Kim, Sung-Moo;Han, Woo-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.99-104
    • /
    • 2007
  • The deep soil mixing, on ground modification technique, has been used for many diverse applications including building and bridge foundations, port and harbor foundations, retaining structures, liquefaction mitigation, temporary support of excavation and water control. This method has the basic objective of finding the most efficient and economical method for mixing cement with soil to secure settlements through improvement of stability on soft ground. In this research, the experiments were conducted on a laboratory scale with the various test conditions of mixing method; the angle of mixing wing, mixing speed. Strength and shapes of improved soil of these test conditions of deep mixing method were analysed. From the study, it was found that the mixing conditions affect remarkably to the strength and shapes of improved soils.

A Study on the Maintenance Method of the Local Government Standard Records Management System (자치단체 표준기록관리시스템 유지관리 방안 연구)

  • Oh, Jinkwan;Yim, Jinhee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.22 no.2
    • /
    • pp.135-154
    • /
    • 2022
  • Through this study, the following proposals were made to secure the operability of local governments' records management systems (RMSs). First, for the stable operation and maintenance of RMS, establishing a noninterruptible system with regular operation support is necessary. Second, improving the maintenance quality above a certain level by establishing an integrated RMS maintenance system is imperative. Third, systematically managing the RMS infrastructure compatibility list should be vital to provide clear standards for maintaining local governments' RMS structure.

Mixing effect of aeration in thermally stratified water (물순환장치 가동에 따른 온도 성층화 혼합 효과)

  • Choi, Seongeun;Hwang, Jin Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.61-61
    • /
    • 2021
  • 온도 성층화는 많은 저수지와 댐에서 흔히 발생하는 현상으로 호수나 저수지의 표면 온도가 바닥보다 상대적으로 높아 깊이에 따른 열 구배를 나타낸다. 이러한 온도 성층화 현상은 여름철과 같이 상부와 하부의 온도 차가 클수록 안정적이게 나타나며 이러한 층화 현상으로 수직 확산이 제어되어 수질에 영향을 미친다고 알려져 있다. 따라서 댐이나 호수 등 층화 현상이 심한 유체 내부 바닥에 물순환장치를 설치하여 외부로부터 공기를 끌어와 하부에서 공기를 분출하여 온도 성층을 약화시키기도 한다. 물순환 장치를 설비하면 수체의 혼합이 용이해지며 물질전달이 개선되어 수질이 향상된다. 국내의 경우 대청댐, 보령댐, 영주 댐 등 많은 국내 댐 내부에 물순환장치가 설비되어있다. 본 연구에서 댐의 물순환장치의 성능을 파악하기 위해 산기식 물순환 장비가 설치되어있는 영주댐을 연구 대상 지역으로 잡았다. 연구지역의 계절별 성층구조 및 특성을 조사하기 위해, 봄, 여름, 가을 영주댐에 방문하여 관측 자료를 취득하였으며 물순환 장치는 봄철의 경우만 가동하였다. 봄철의 물순환 장치 가동 전후 관측 데이터를 바탕으로 수치모형실험을 실행하여 관측 결과와 비교 및 검증하였다. 이를 바탕으로 여름, 가을에 물순환장치를 가동하였을 경우 댐 내부 수체의 혼합과정을 살펴보는 연구를 진행하였다. 본 연구는 CFD (Computational Fluid Dynamic) 시뮬레이션을 수행하기 위해 오픈 소스 소프트웨어 OpenFOAM(version 4.0)에서 열 전달이 포함되어있는 비압축성 VOF 솔버를 사용하였다. 본 솔버는 물과 공기를 동시에 나타낼 수 있으며 온도의 확산 방정식을 포함하고 있다. 또한 유동해석 수행 시 사용한 물순환장치의 효울은 실제 장치의 효율과 동일하다. 본 연구의 목표는 다음과 같다. (1) 관측만으로 파악하기 어려운 수체의 혼합거동을 유동해석 자료를 통해 면밀히 살펴보고 (2) 봄철 물순환 장치가 작동하기 전후 자료를 바탕으로 여름 및 가을철 물순환장치 가동 전후 데이터를 유동해석 자료로 취득한다. (3) 또한 물순환장치 가동 전후 데이터를 통해 계절별 혼합 효율을 취득한다.

  • PDF

A numerical study on feasibility of the circled fiber reinforced polymer (FRP) panel for a tunnel lining structure (터널 라이닝 구조체로서 곡면 섬유강화 복합재료의 적용성 검토를 위한 수치해석적 연구)

  • Lee, Gyu-Phil;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.6
    • /
    • pp.451-461
    • /
    • 2010
  • Utilization of the fiber reinforced polymer (FRP) material has been enlarged as a substitution material to the general construction materials having certain long-term problems such as corrosion, etc. However, it could be difficult to apply the FRP material, which has a linear shape generally, to an arch-shaped tunnel structure. Therefore, an attempt has been made in this study to develop a device to form a designed cross section of FRP material by pulling out with a curvature. A sample of the circled FRP product was successfully produced and then the sample has been tested to identify its physical characteristics. Then, intensive feasibility studies on the circled FRP panel to be used for a tunnel lining structure have been carried out by numerical analyses. As a result, it appears that the new circled FRP-concrete composite panel has a high capability to be used for a tunnel lining material without any structural problem.

Design and Implementation of Bigdata Platform for Vessel Traffic Service (해상교통 관제 빅데이터 체계의 설계 및 구현)

  • Hye-Jin Kim;Jaeyong Oh
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.887-892
    • /
    • 2023
  • Vessel traffic service(VTS) centers are equipped with RADAR, AIS(Automatic Identification System), weather sensors, and VHF(Very High Frequency). VTS operators use this equipment to observe the movement of ships operating in the VTS area and provide information. The VTS data generated by these various devices is highly valuable for analyzing maritime traffic situation. However, owing to a lack of compatibility between system manufacturers or policy issues, they are often not systematically managed. Therefore, we developed the VTS Bigdata Platform that could efficiently collect, store, and manage control data collected by the VTS, and this paper describes its design and implementation. A microservice architecture was applied to secure operational stability that was one of the important issues in the development of the platform. In addition, the performance of the platform could be improved by dualizing the storage for real-time navigation information. The implemented system was tested using real maritime data to check its performance, identify additional improvements, and consider its feasibility in a real VTS environment.

A Study on the Development of Charging Algorithm for Battery Charger Control Unit of the T-50 Series Aircraft (T-50 계열 항공기 배터리 시스템의 충전제어장치 알고리즘 개선에 관한 연구)

  • Jaejeong Kim;Soonyoung Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.144-148
    • /
    • 2023
  • Aircraft battery is the core equipment of an aircraft that supplies engine starting power and emergency power, and it must be charged to ensure sufficient capacity at all times and maintain high reliability to ensure stable power supply. The battery of the T-50 series aircraft is designed to enable the engine to start up to two times in temperatures as low as -18℃ and above. However, intermittent failures in engine starting have been observed during winter. In this paper, we analyze the failure phenomena occurring during low-temperature charging of the battery and improve the charging algorithm based on the analysis and test. Additionally, the results of start simulation tests show that the battery charging defects at low temperatures are resolved, and an improvement in the charging performance is confirmed; thus, validating the effectiveness of the new algorithm.

A Design of Temperature Management System for Preventing High Temperature Failures on Mobility Dedicated Storage (모빌리티 전용 저장장치의 고온 고장 방지를 위한 온도 관리 시스템 설계)

  • Hyun-Seob Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.125-130
    • /
    • 2024
  • With the rapid growth of mobility technology, the industrial sector is demanding storage devices that can reliably process data from various equipment and sensors in vehicles. NAND flash memory is being utilized as a storage device in mobility environments because it has the advantages of low power and fast data processing speed as well as strong external shock resistance. However, flash memory is characterized by data corruption due to long-term exposure to high temperatures. Therefore, a dedicated system for temperature management is required in mobility environments where high temperature exposure due to weather or external heat sources such as solar radiation is frequent. This paper designs a dedicated temperature management system for managing storage device temperature in a mobility environment. The designed temperature management system is a hybrid of traditional air cooling and water cooling technologies. The cooling method is designed to operate adaptively according to the temperature of the storage device, and it is designed not to operate when the temperature step is low to improve energy efficiency. Finally, experiments were conducted to analyze the temperature difference between each cooling method and different heat dissipation materials, proving that the temperature management policy is effective in maintaining performance.

Walking test for assessing lung function and exercise performance in patients with cardiopulmonary disease (심폐질환 환자에서 걷기검사를 이용한 폐기능 및 운동기능의 평가)

  • Jung, Hye Kyung;Chang, Jung Hyun;Cheon, Seon Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.976-986
    • /
    • 1996
  • BACKGROUND : Dyspnea is common among patients with cardiopulmonary disease, and "daily disability" is defined as a functional impairment resulting from exercise intolerance. The maximal oxygen uptake(VO2max) during exhausting work is not only the best single physical indicator of the capacity of a man for sustaining hard muscular work, but also the most objective method by which one can determine the physical fitness of an individual as reflected by his cardiovascular system. However, the expense, time and personnel requirements make this procedure prohibitive for testing large group. The walking test is well-known type of exercise and it cost nothing to perform and have good reproducibility. Thus we performed the walking test and investigated correlations with spirometry, ABG and exercise test. METHOD: We observed the walking test and exercise test by cycle ergometer in 37 patients who visited our hospital because of dyspnea. Arterial blood gas analysis and spiromety, dyspnea index were performed, too. RESULT : (1) The VO2max was significantly lower in patients with COPD and cardiovascular disease than asthma and dyspnea on exertion group(p<0.05). The walking test distance was also lower in former. (2) The 12 minute walking test was significantly correlated with VO2max, PaCO2, FVC(%), FEV1(%) in all patients(p<0.05), and the walking test was only conelated with VO2max in patients with COPD(p<0.05). (3) In COPD patients, the VO2max was best correlated with FEV1(%) and FVC(%) and significantly correlated with walking test. But there was no correlation between walking test and FEV1(%) & FVC(%). (4) The 6 minute walking test was well correlated with 12 minute walking test(r=0.92. p<0.01). CONCLUSION : The walking test is the simple method for assessing exercise performance in patient with cardiopulmonary disease and a reliable indicator for VO2max. And the walking test is practical method for assessing on everyday disability rather than maximal exercise capacity. The 6 minute walking test is highly correlated with 12 minute walking test and a less exhausting for the patients and a time-saving for the investigator.

  • PDF