• Title/Summary/Keyword: 안전 성능

Search Result 4,363, Processing Time 0.035 seconds

전기설비의 안전관리

  • 최연수
    • Electric Engineers Magazine
    • /
    • v.203 no.7
    • /
    • pp.40-46
    • /
    • 1999
  • 최근 전기설비는 자동화, 안전화되고 또한 인간에게 쾌적하고 편리한 시설을 지공하며 계획단계부터 설계, 시공을 거쳐 실현된 당초 성능이나 기능을 지속적으로 유지하고 안전을 보장하는 모든관리를 전기설비의 안전관리라 할 수 있다.

  • PDF

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

A Study on Reliability, Safety Analysis and Related Performance Improvement of Avionics Equipment (항공전자장비 신뢰성, 안전성 분석 및 관련 성능 개선 방안 연구)

  • Seo, Joon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.9
    • /
    • pp.1220-1227
    • /
    • 2018
  • Avionics electronic equipment refers to the electronic equipment installed on an aircraft. Failure of avionics equipment can have a significant impact on aircraft operations as well as threaten the safety of pilots and passengers. Therefore, avionics electronic equipment is required to have higher reliability and safety than electronic equipment used for other purposes. Avionics equipment must consider various component selection and system design to meet reliability and safety-related requirements from the initial design stage. In this paper, we describe safety, reliability performance analysis method of avionics equipment, and introduce various design improvement methods that can be performed to meet safety requirement performance. Finally, the safety performance of the improved avionics equipment was reanalyzed and compared with the value before the improvement, the validity of the proposed design change was verified.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

Development of Performance Test Procedure for the Excess Flow Valve for Buried Piping for the Domestic LPG Mass Supply System (국내 LPG 집단공급시설 환경에 적합한 매몰배관용 과류차단밸브 성능시험 절차 개발)

  • Jang, Chanyeong;Lee, Ugwiyeon;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.16-27
    • /
    • 2018
  • Since 2014, the Korean government has begun distributing LPG pipelines and LPG tankers to mountainous or island areas where it is difficult to open urban gas supply chains. When installing LPG supply facilities at village level and county level, it supplied consumers with 10 times higher quasi-low pressure (25 kPa to 100 kPa) than conventional gas supply pressure, increasing the risk of gas accident. Due to the pressure that is 10 times higher than the conventional gas supply pressure, large amounts of gas are released at a faster rate when leaked. In order to secure safety of quasi-low-pressure gas pipes, excess flow valves for quasi-low-pressure gas pipes are not developed and are not supplied in Korea. Therefore, Korea Gas Safety Corporation is investigating the performance standards and products of the excess flow valves in order to localize the excess flow valves.

Development of Deep Learning-Based Damage Detection Prototype for Concrete Bridge Condition Evaluation (콘크리트 교량 상태평가를 위한 딥러닝 기반 손상 탐지 프로토타입 개발)

  • Nam, Woo-Suk;Jung, Hyunjun;Park, Kyung-Han;Kim, Cheol-Min;Kim, Gyu-Seon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.107-116
    • /
    • 2022
  • Recently, research has been actively conducted on the technology of inspection facilities through image-based analysis assessment of human-inaccessible facilities. This research was conducted to study the conditions of deep learning-based imaging data on bridges and to develop an evaluation prototype program for bridges. To develop a deep learning-based bridge damage detection prototype, the Semantic Segmentation model, which enables damage detection and quantification among deep learning models, applied Mask-RCNN and constructed learning data 5,140 (including open-data) and labeling suitable for damage types. As a result of performance modeling verification, precision and reproduction rate analysis of concrete cracks, stripping/slapping, rebar exposure and paint stripping showed that the precision was 95.2 %, and the recall was 93.8 %. A 2nd performance verification was performed on onsite data of crack concrete using damage rate of bridge members.

Reconfigurable Simulator for Safety Evaluation of eVTOL Aircraft (eVTOL 항공기 안전성 평가를 위한 가변형 시뮬레이터 구축)

  • Hyeji Kim;Jeongmin Kim;Dayeon Yoon;Jongjun Ha;Dongjin Lee;Jangho Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.95-101
    • /
    • 2024
  • This paper aims to establish a reconfigurable flight simulation environment to conduct safety evaluation of various electric vertical take-off and landing (eVTOL) aircraft. Since the inceptor, aircraft dynamics model, and controller applied to each eVTOL aircraft are different, it was configured to be variable so that a simulation can be executed for each eVTOL aircraft. Test elements and performance indicators were set to perform safety evaluation of eVTOL aircraft. Ground auxiliary equipments were designed and implemented in a simulation environment according to test procedures for each test element. In addition, to analyze safety performance, a simulation flight data collection environment based on MATLAB/Simulink and a tool for safety performance analysis were implemented. Test flight and analysis were conducted in the implemented simulation environment in this paper. Finally, this study shows the environment was verified by confirming that it was performed normally.

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

A Study of Deduction of evaluation Items for Design of SOFC stack safety performance evaluation system (SOFC 스택 안전성능 평가 시스템 제작을 위한 평가항목 도출에 관한 연구)

  • Park, Tae-Seong;Nam, Tae-Ho;Lee, Duk-Gwon;Lee, Seung-Kuk;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.81-87
    • /
    • 2017
  • SOFC(Solid Oxide Fuel Cell) is one of the high-temperature fuel cells, SOFC system and Stack has a high temperature operating Characteristics. These Characteristics cause a lot of trouble in the design of the system and selection materials, securing durability, and securing safety performance. Therefore, For Commercialization and Supply of SOFC, the development of safety performance assessment techniques and evaluation systems should go together. In this study, we analyzed the evaluation items of SOFC Safety performance standards and risk factors of the stack for design of stack safety performance evaluation system. Based on the analyzed data, the evaluation item was deducted for design of stack safety performance evaluation system. Through the results of this study, we expect to facilitate the supply of SOFC and contribute to a safe use environment.