• Title/Summary/Keyword: 안전작동

Search Result 558, Processing Time 0.029 seconds

Improvement and Application of Pump Station Operating System and Economic Analysis of the Application (빗물펌프장 운영시스템 개선 및 적용과 경제효과분석)

  • Joo, Jin- Gul;Yoo, Do-Guen;Yang, Jae-Mo;Jung, Dong-Hwi;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • In low-lying districts of urban areas, pump stations were built to protect flooding by the heavy rain. Particularly, the automatic pump operation system was installed for efficiency in the pump stations of Seoul. However, the effective pump operation is difficult under existing operating system because the system only performs operation by reservoir depth. This study would like to improve the real time operating system suggested by Jun et al.(2007) and to apply the system Gasan 1 pump station in Seoul. For various design rainfall events, maximum water levels simulated by the suggested system were 10~70cm lower than results by the existing system. And overflow volume at upstream manholes were 50% reduced. We converted the flood control effects by establishment of the suggested system to economic indicators. To obtain the same effect, approximately 4.9 billion won needs to expand pump capacities or 3.2~6.9 hundreds million won needs to construct storm water detention on upstream area. The suggested system could improve the flood control stability by efficient operation of the existing pump station.

A Study on Intelligent Mobility Enhancement System for the Mobility Handicapped (첨단 교통약자 보호시스템에 대한 연구)

  • Han, Woong-Gu;Shin, Kang-Won;Choi, Kee-Choo;Kim, Nam-Sun;Sohn, Sang-Hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.25-37
    • /
    • 2010
  • This study is aimed at enhancing mobility rights for the transportation underprivileged that has been made light of relatively compared to normal people. In order to do this, we've suggested having ITS (Intelligent Traffic System) built and improving satisfaction through the test operation of its main system. The existing sound signal device for the visually handicapped has one problem with managing it. Because, the people in charge of it had to visit each problematic site directly to maintain and fix some problems every time it was out of order. Moreover, it couldn't provide sustainable services about voice guidance and the visually handicapped had to control it by either confirming the location of buttons that were installed on the pillar of traffic light and then pressing one of them or using a remote controller on their own. In order to improve such inconveniences, we have created a new typed sound signal device for the visually handicapped by applying the cutting-edge wireless technology based on ergonomics considering actual road situations. Such technology enables it report the status of signal device and light to them by using its voice guidance system automatically every time they have access to it. Additionally, we've already introduced it to a couple of test areas and then known the fact that they recognized traffic situation more conveniently and safely compared to the existing sound signal device. That is above average in terms of satisfaction. In addition to that, we've provided LTS (Location Tracking System - Location-based service intended for elementary students) by utilizing the existing wireless infrastructure and founded the fact that about 87% of their parents were satisfied with the service based on LTS.

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.

Experimental Performance Evaluation of a Fire System for Apartment Buildings (공동주택 전용화재시스템의 성능평가를 위한 실험적 연구)

  • Jung, Jong-Jin;Hong, A-Reum;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.51-56
    • /
    • 2015
  • In Korea, measures to maintain sustainable fire safety performance for apartment buildings are insufficient in terms of fire-fighting products, skilled personnel, and maintenance status. Also, because of the particular features of a fire compartment, it has structural problems that are very likely to cause damage to human life when a fire occurs. Currently, problems with the fire supervisory system installed in an apartment building cannot be checked in real time, so it is difficult to identify the location of a fire accurately. Protected areas are also not assigned to each household, and residents cannot be clearly informed of the occurrence of a fire. As a consequence, safety evacuation cannot be secured. In addition, it is impossible to test the operation performance for water detectors in sprinkler fire extinguishing systems outside of the household. Therefore, an experiment was conducted to evaluate the performance of a remote fire supervisory system. The results show that the system satisfies all performance requirements. Also, an household alarm system was installed in each household to alert of any occurrence of a fire accurately, and the performance of the alarm system was improved to ensure that residents were quickly evacuated.

A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads (상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;Lee, Jaewon;Kim, Taejin;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2017
  • The purpose of this study is to investigate the effect of vertical and horizontal refraction on the lower part of the power supply and control system of various facilities and machinery that use electricity, so that the power distribution system, which is an important electric facility installed in buildings and public facilities, Type earthquake resistant pads to protect the substructure and prevent short-circuiting on the upper part of the system. The GR-63-CORE (Scale 8.3 class) It is earthquake disaster prevention and disaster prevention technology that satisfies seismic performance. As a research result, it is possible to protect the electricity and communication infrastructure, which can contribute to shortening the time for recovering the electric facilities to the normal state in case of an earthquake, and preventing the fire caused by the destruction of the electricity supply facility in case of an earthquake. As a result, it is possible to minimize the spread of fire that occurs when a large-scale earthquake occurs and to minimize the damage of people and damage to property, and it can contribute to the securing of electric infrastructure that enables citizens to quickly recover to daily life even after suffering a major earthquake. In addition, the technology can be applied to ensure the seismic resistance of the equipment in the communication and computer room, and it can be applied to various fields where the facility function can be stopped due to the shaking of the earthquake base.

The Flow Behavior Characteristics of Methane with Phase Change at Low Heat Flux (저열유속에서 상변화를 수반하는 메탄의 유동거동특성)

  • Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.1
    • /
    • pp.96-103
    • /
    • 2014
  • A liquefied natural gas(LNG) in cryogenic liquid is converted back into gaseous form for distribution to residential and industrial consumers. In this re-gasification process, LNG supplies a plenty of cold thermal energy about $83.7{\times}10^4kJ/kg$. The LNG cold thermal energy is utilized for the re-liquefaction process of cryogenic fluids such as Nitrogen, Hydrogen and Helium, and ice manufacturing process and air-conditioning system in some advanced countries. Therefore, it is also necessary to establish the recovery systems of the LNG cold thermal energy around Incheon, Pyungtaek and Tongyung LNG import terminals in our country. Methane is used as working fluid in this paper, which is the major component of LNG over 85 % by volume, in order to investigate the flow behavior characteristics of LNG with phase change at low heat flux. This paper presents the effects of pipe diameters, pipe inclinations and saturation pressures on the flow boundaries of methane flowing in a cryogenic heat exchanger tube, together with those of nitrogen, propane, R11 and R134a. The outcomes obtained from this theoretical researches are also compared with previous experimental data. It was also found that the effect of pipe inclination on the methane flow boundaries was significant.

Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant (원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석)

  • Kim, Beom-Gyu;Lim, Heok-Soon;Lee, Young-Seung;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.74-81
    • /
    • 2016
  • This study evaluated the habitability of operators for main control room fires in nuclear power plants. Fire modeling (FDS v.6.0) was utilized for a fire safety assessment so that it could determine the performance of the smoke ventilation and operator habitability with the main control room. For this study, it categorized fire scenarios into three cases depending on the conditions in the HVAC system. As a result of fire modelling, it showed that Case 1 (with HVAC) would give rise to the worst situation associated with the absolute temperature, radiative heat flux, optical density, and smoke layer height as deliberating the habitability and smoke ventilation. On the other hand, it showed that Cases 2 (w/o HVAC) and 3 can maintain much safer situations than Case 1. In the case of temperature at 820 s, Cases 2 and 3 were up to approximately 63% greater than Case 1 in the wake of ignition. In addition, the influence of radiative heat flux of Case 1 was even larger than Cases 2 and 3. That is, the radiative heat fluxes of Cases 2 and 3 were approximately 68% higher than Case 1. Furthermore, when it comes to considering the optical density, Case 1 was approximately 93% greater than Cases 2 and 3. Accordingly, it expected that the HVAC system can influence a the performance on the smoke ventilation that can be sustainable for operator habitability. On the other hand, it revealed an inconsecutive pattern for the smoke layer height of Cases 2 and 3 because supply vents and exhaust vents were installed within the same surface.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

Dynamic Analysis of 3 Different Cross-Sectional Shapes of a Fill Dam using 3D FEM Analysis (3차원 유한요소해석에 의한 필 댐의 3가지 단면 형상을 고려한 지진해석)

  • Choi, Byoungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.37-43
    • /
    • 2015
  • Dam movements are identified in real-time with measuring instruments for dam maintenance. However, for dams that have aged, the measuring instruments that were installed during the dam construction are frequently malfunctioning or completely failing altogether. Precision safety diagnosis is being executed for dams that are national facilities Type 1. During the diagnosis, a safety assessment is conducted for the dam body. Normally, during the analysis of dam safety, the widest cross-section is selected and a two-dimensional numerical analysis is taken place for the cross-section. However, numerous researchers have recently looked into applying the 3-dimensional numerical analysis program developments to precisely analyze the structure of the dam, as well as the surrounding strata, and the lower dam strata. In this study, PLAXIS 3D, a geotechnical generic FEM analysis program, was used to conduct dam safety assessments for earthquakes. The following were compared and analyzed: considering the seismic properties of the dam body with all zoned structures reflected as one rock-fill zone together with the dam body, considering the dam body as the rock-fill zone and the core zone, and the numerical analysis results. Thus, the study was aimed to analyze the impact properties of seismic waves according to the different zones.

Behavioral Analysis of Silt Protectors in Seawater Using the Mass-Spring Model (질량-스프링 모델을 이용한 해수 중 오탁방지막 거동해석)

  • Lee, Choon-Woo;Kim, Ok-Sam;Shin, Hyun-Chool;Hwang, Doo-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.194-199
    • /
    • 2017
  • When sea tide and wave velocity change, the behavior of silt protectors underwater changes, and a hydraulic force exceeding the anchor wave force is applied. In this study, the movement mechanism of a silt protector has been analyzed using the mass-spring method. The initial position of the silt protector was in the Jindo area near Gwangpo Port (742-1, Gyupori, Chongdo-myeon, Jindo-gun, Jeonnam, Korea). The tension required to exceed the holding power of the anchor was 0.05 m/s at 318 sec., 0.15 m/s at 77 sec., 0.25 m/s at 43 sec., and 0.3 m/s at 37 sec.. As the anchor started to move from the sea floor and the tide speed increased to 0.01 m/s, anchor movement start time shortened by an average of 11.2 sec.. Compared with when tide was the only affecting factor, the silt protector and anchor were found to have moved 19.7 % at 0.1 m/s, 7.6 % at 0.15 m/s, 5.8 % at 0.2 m/s, 4.3 % at 0.25 m/s and 2.8 % at 0.3 m/s, showing an increase. When wave effect was added to the tide, anchor movement started when the flow rate was slow 7.6 % of the time. With a high flow velocity, anchor movement started without any significant difference less than 4.3 % of the time. When tide speed exceeded 0.13 m/s and the direction of the waves matched, the silt protector was not able to perform due to collisions with surrounding sea structures. When installing a silt protector, the fluid flow situation and the silt protector situation must be carefully analyzed using the mass-spring method to apply the result found in this study.