• Title/Summary/Keyword: 안전성능

Search Result 4,377, Processing Time 0.031 seconds

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building - (우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 -)

  • Lee, Se-Myong;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-41
    • /
    • 2011
  • Regulation of Escape and fire-prevention of Building of South Korea were enacted as a part of building codes in 1962. Since it was enacted, the law has gone through many changes. In this study, evaluated the fire safety of the law about the case of a hotel that the fire risk are expected to be higher whenever it was changed. As a result, the current law has gotten better in tire safety since it was enacted. However, especially it could be confirmed that the evacuation safety is insufficient in the lower level of hotel building. In the case of accommodation, because the occupants become aware of fire lately, they have not enough time to escape. Therefore, this study suggests that it is needed to come up with an effective counterplan about the interior finish materials, fire door and fire compartments that the smoke layer descending time is longer.

Performance Analysis and Improvement of National Fire Safety Code elements of Sprinkler System (스프링클러설비의 화재안전기준 요소의 성능분석 및 개선방안)

  • Oh, Taekhum;Lee, Jungil
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.413-422
    • /
    • 2013
  • This study evaluated the fire safety code elements through analyze the loss of life when the fire occurred in the facility sprinklers installed evaluated. And through comparison with national fire safety code elements and standards of NFPA 13 in the United States, Was looking for ways to improve for Life and property damage. In the United States, in some cases, if you do not install the sprinkler are installed as per the fire death rate compared to 83 % lower. By contrast, If the domestic rate of 280 % fatalities were 3.37 times than the United States. This lack of fire performance were analyzed uniform occupancy classification, the amount of source of water supply, live not consider the density according to the standard number and the horizontal distance that causes the installation of sprinkler facilities were analyzed.

The Classification Plan on Safety Certification System of Temporary Equipment (건설 가설재의 안전인증 분류방안)

  • Park, Sang-Wook;Park, Jun-Mo;Kim, Ok-Kyue
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.794-799
    • /
    • 2008
  • At the point of changing from the capacity qualification of temporary equipments for building to safety certification system, the meaning of qualification and the present state of main products are evaluated for Capacity qualification system and compare with related system in developed country. These suggest classification of temporary equipments for building construction in safety certification. Now, present state of the capacity qualification system is estimated; according to the reforming system from restating law in 2003, there are a lot of changing of application in every 3 years because of that. The ability of Making business is improved by checking again but, there are limitation to constantly keep the safety as the system to approve form about sent imitation products. Changing from the capacity qualification system to safely certification system make to include the structure of the qualification system and make a plan standard. It make least panic in the building market and set up some standards for capacity by changing building circumstance. The classification of temporary equipment for building construction in safety certification from the module of quotation form classify each duty quotation item, self-regulation safely verification item and option quotation item, these will more improve the system form and quality of temporary equipment for building than before.

  • PDF

A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station (수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구)

  • Hwayoung, Lee;Hyeonwoo, Jang;Minkyung, Lee;Jeonghwan, Kim;Jaehun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.30-36
    • /
    • 2022
  • In commercial transactions of energy sources using hydrogen charging stations, high-accuracy flow meters are needed to prevent accidents such as overcharging due to inaccurate measurements and to ensure transparency in hydrogen commercial transactions through accurate measurements. This research developed a Corioli-type flowmeter prototype and conducted a risk assessment to prevent accidents during a process change comparison experiment for existing charging stations to verify the measurement performance. A process change section was defined for the installation of measurement facilities for empirical experiments and HAZOP was conducted. In addition, JSA was also conducted to secure the safety of experimenters, such as preventing valve mis-opening during empirical experiments. Measures were established to improve the risk factors derived through HAZOP, and work procedures were established to minimize human errors and ensure the safety of workers through JSA. The design change and system manufacturing for the installation of the metering system were completed by reflecting the risk assessment results, and safety could be confirmed through the performance comparison test of the developed meter prototype. The developed prototype flow meter showed a total of 30 flow measurements under the operating conditions of 70 MPa, and the average error was -1.58% to 3.96%. Such a metering error was analyzed to have the same performance as a flow meter installed and operated for commercial use.

Development of performance testing technique and equipments for the DC T/C characteristics of miniature fuses (소형퓨즈의 DC용단특성 성능평가기술 및 설비 개발)

  • Kim, Geun-Yong;Park, Nam-Ok;Park, Sung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.847-848
    • /
    • 2006
  • 최근 안전인증 기술기준의 국제규격(IEC) 부합화에 따라 소형 퓨즈의 DC 시간/전류 특성(DC Time/Current characteristic, 이하 DC 용단특성)에 대한 시험이 중요한 성능평가항목으로 부각되고 있다. 특히 DC 용단특성을 시험하기 위해서는 규격에 적합한 DC 발생기 및 DC 용단시간도 정확하게 측정할 수 있는 시스템이 구축되어야 하므로, 그 성능 평가설비 또한 매우 중요하다고 할 수 있다. 본 논문에서는 안전기준 및 IEC 국제규격을 분석하고, 분석된 규격을 토대로 성능평가설비를 설계하여 국제적 수준의 시험기관 위상에 걸맞은 성능평가기술 기반을 구축하였다. 구축된 설비 및 개발된 성능평가기술은 향후 시험평가기술의 국제화에 중요한 역할을 할 것으로 기대된다.

  • PDF

Automatic Fire Detector Spacing Calculation for Performance based Design (성능위주설계를 위한 화재감지기배치의 공학적연구)

  • Yoon, Myong-O;Park, Dong-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.180-189
    • /
    • 2010
  • 현재의 화재안전기준에서 규정하는 화재감지기의 배치방법은 면적에 따라 규정된 숫자를 적정하게 배치하는 수준이다. 이 기준은 과학적인 근거는 가지고 있지 못하다. 외국의 기준을 도입하여 그에 따라서 설치하고 있을 뿐이다. 소방시설을 설계하는 방법에는 화재안전기준과 같이 명문화 된 규정에 따르는 규범위주설계(Prescriptive-Based)와 화재역학, 구조역학, 재료역학, 유체역학, 열역학 등 공학적 지식을 바탕으로 하는 성능위주설계(Performance-Based Design)가 있다. 현재로서는 성능위주설계가 활성화 되지 않았지만, 최근 소방시설공사업법은 성능위주설계방법을 이용하여 소방시설을 설계 할 수 있도록 개정('05. 8. 4)되었으며 그 시행령('07, 1. 24)에서 성능위주설계를 적용할 특정소방 대상물의 범위를 정하고 있다. 이러한 시점에서 자동화재탐지설비의 화재감지기를 최적의 위치 및 거리에 설치하기 위하여 그에 대한 공식의 도입과 공식을 Software로 계산할 수 있도록 시뮬레이터를 제작하여 계산하고 규범위주설계에 따라 배치한 화재감지기의 상태와 비교 분석하며 향후 성능위주설계 방법으로서 정착시키기 위하여 연구를 시도하였다.

  • PDF

A Study on Selection of Target Performance for Performance Evaluation and Maintenance of Retaining Wall in Korea (국내 옹벽의 성능평가와 유지관리를 위한 목표 성능 선정에 관한 연구)

  • Choi, Jae Soon
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.111-121
    • /
    • 2019
  • In the revised 2019 Guidelines for Facility Safety and Maintenance, the existing safety-oriented facility evaluations have expanded from performance evaluations to added durability and serviceability. This expansion reflects the life cycle of facilities and the service abilities of facilities, which are becoming a global issue. However, since the performance evaluation of facilities is linked to repairing and reinforcement, the related researches such as the correlation of each performance and the target performance related to the decision on priority are necessary. In this study, through the analysis of historical data of existing facility safety evaluation results centered on the retaining earth wall installed in domestic road facilities, the appropriate target performance was suggested for the maintenance of the facility based on the revised performance evaluation. Also, the performances on the actual two retaining walls were evaluated for example and analyzed the verification of the target performance. Besides, new indicators were presented to add serviceability to the performance evaluation of retaining earth walls consisting of safety and durability.

Developments of performance-based assessment technique for existing tunnels (공용중인 터널의 성능중심 평가기법 개발)

  • An, Jai-Wook;Kim, Hong-Kyoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.525-533
    • /
    • 2016
  • The purpose of current tunnel maintenance system in South Korea is safety-based maintenance system for accident prevention, So it is difficult to conduct a strategic maintenance. The development of a new maintenance system can lead to effective investment of limited financial and it's effort is still in progress. In this study, to develop a performance-based assessment method, indexes for assessment are derived taking into account the safety, durability and serviceability. The indexes for performance-based assessment were selected by a literature analysis and a delphi survey. Then the importance among indexes were calculated by the AHP analysis.