• Title/Summary/Keyword: 안전구조

Search Result 6,967, Processing Time 0.033 seconds

Critical Strengthening Ratio of CFRP Plate Using Probability and Reliability Analysis for Concrete Railroad Bridge Strengthened by NSM (확률.신뢰도 기법을 적용한 CFRP 플레이트 표면매립보강 콘크리트 철도교의 임계보강비 산정)

  • Oh, Hong-Seob;Sun, Jong-Wan;Oh, Kwang-Chin;Sim, Jong-Sung;Ju, Min-Kwan
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.6
    • /
    • pp.681-688
    • /
    • 2009
  • The railroad bridges have been usually experienced by vibration and impact in service state. With this reason, it is important that the effective strengthening capacity should be considered to resist the kind of service loading. In this study, NSM strengthening technique is recommended for the concrete railroad bridge because of its better effective resistance for dynamic loading condition and strengthening cost than the conventional externally bonded strengthening using fiber sheet. However, to widely apply NSM method for the concrete railroad bridge, it needs that the strengthening ratio has to be reasonably evaluated with geometrical and material uncertainties, especially for the concrete bridge under long-term service state without the apparent design history and detail information such as concrete compressive strength, reinforcing ratio, railroad characteristics. The purpose of this study is to propose the critical strengthening ratio of CFRP plate for the targeted concrete railroad bridge with uncertainties of deterioration of the structures. To do this, Monte Carlo Simulation (MCS) for geometrical and material uncertainties have been applied so that this approach may bring the reasonable strengthening ratio of CFRP plate considering probabilistic uncertainties for the targeted concrete railroad bridge. Finally, the critical strengthening ratio of NSM strengthened by CFRP plate is calculated by using the limit state function based on the target reliability index of 3.5.

Damping System Design for Apartment Buildings Using Equivalent Frame Model (등가프레임모델을 이용한 공동주택의 감쇠시스템 설계)

  • Kim, Jong-Ho;Lee, Myoung-Kyu;Chun, Young-Soo;Lee, Dong-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.351-360
    • /
    • 2014
  • The purpose of this research is to introduce the simplified equivalent frame model for the equivalent lateral force procedure, the response spectrum procedure and nonlinear procedure according to ASCE7-10 in order to reduce the time of performance and reasonably evaluate the effect of applying the damping system with the various conditions for the analysis and the variable. In this research, the seismic performance assessment and the design of the damping system were conducted through the nonlinear time history analysis based on the performance based seismic design in ASCE7-10 in regard to applying the damping system to apartment buildings which is lately issued. The optimal design based on the 75% of seismic base shear was performed for an apartment building. The seismic performance assessment were conducted to check the safety of the building, and the economic evaluation was performed by comparing the amount of resource for the optimal designed building with the amount of resource for the original building. In addition, hysteresis dampers was applied to the apartment building, and the suggested equivalent frame model was performed using the damping system design in ASCE7-10, then its control effects were proved in the full scale model of the apartment building which was used in this research.

Toxicity Evaluation of 30 kGy Irradiated Dried Space Bibimbap for Three Months (우주식품으로 개발한 30 kGy 감마선 조사된 건조우주비빔밥의 3개월 독성평가)

  • Park, Jae-Nam;Kim, Jin-Kyung;Choi, Dan-Bi;Kim, Jae-Hun;Song, Beom-Seok;Lee, Ju-Woon;Kang, Il-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.7
    • /
    • pp.956-961
    • /
    • 2011
  • This study was conducted to evaluate the possible subacute toxicity of gamma-irradiated dried bibimbap. The dried bibimbap was irradiated at the dose of 30 kGy at room temperature. For the animal study, the male and female ICR mice (8 mice per group) had the diet with AIN39G as control and dried bibimbap 30 kGy irradiated and non-irradiated for three months. During the experimental period, the group with 30 kGy irradiated bibimbap did not show any changes in appearance, behavior, mortality, body weight, organ weight, and food consumption compared to the control. Also, all of the biochemical parameters were observed in the normal ranges. In histopathological examination including hematological and serum biochemical analyses, there were no significant differences among the control and 30 kGy irradiated dried bibimbap groups. These results indicate that irradiation of bibimbap up to 30 kGy did not cause any toxic effects and could be applied for the development of safe ready-to-cook food.

Accuracy Evaluation of 3D Slope Model Produced by Drone Taken Images (드론 촬영으로 작성한 비탈면 3차원 모델의 품질 분석)

  • Kang, Inkyu;Kim, Taesik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.6
    • /
    • pp.13-17
    • /
    • 2020
  • In the era of the fourth industrial revolution, drones are being used in various civil engineering fields. Currently, the construction and maintenance of slopes are generally managed by manpower. This method has a risk of safety accidents, and it is difficult to accurately evaluate the slope because it is difficult to secure the vision. In this paper, the effects of RTK and GCP on the 3D model of the slope were studied by using digital images taken by the drone. GNSS coordinates were measured for nine points to compare the quality of the slope 3D model, three points of which were used as the check points and the remaining points were used as GCPs. When making the 3D model of the slope using high-accuracy geotagging images using RTK, it was found that the error at the check point decreases as the number of GCP increases. Even if GNSS was used, it was found that the error at the check points of the 3D slope model was not significant when the GCPs were applied. However, it was found that even if high-accuracy geotagging images are used using the RTK module, a significant error occur when the 3D slope model is created without applying GCPs. Therefore, it can be stated that GCP must be applied to create the 3D slope model in which information about the height as well as plane information is important.

Prediction of Shear Strength in High-Strength Concrete Beams without Web Reinforcement Considering Size Effect (크기효과를 고려한 복부보강이 없는 고강도 콘크리트 보의 전단강도 예측식의 제안)

  • Bae, Young-Hoon;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.820-828
    • /
    • 2003
  • Recent research has indicated that the current ACI shear provision provides unconservative predictions for large slender beams and beams with low level of longitudinal reinforcement, and conservative results for deep beams. To modify some problems of ACI shear provision, ultimate shear strength equation considering size effect and arch action to compute shear strength in high-strength concrete beams without stirrups is presented in this research. Three basic equations, namely size reduction factor, rho factor, and arch action factor, are derived from crack band model of fracture mechanics, analysis of previous some shear equations for longitudinal reinforcement ratio, and concrete strut described as linear prism in strut-tie model deep beams. Constants of basic equations are determined using statistical analysis of previous shear testing data. To verify proposed shear equation for each variable, effective depth, longitudinal reinforcement ratio, concrete compressive strength and shear span-to-depth ratio, about 300 experimental data are used and proposed shear equation is compared with ACI 318-99 code, CEB-FIP Model code, Kim &Park's equation and Zsutty's equation. The proposed shear equation is not only simpler than other shear equations, it is but also shown to be economical predictions and reasonable safety margin. Hence proposed shear strength equation is expected to be applied to practical shear design.

Shear Capacity of Precast Concrete Triple Ribs Slab (프리캐스트 콘크리트 트리플 리브 슬래브의 전단성능)

  • Hwang, Seung-Bum;Seo, Soo-Yeon;Lee, Kang-Cheol;Lee, Seok-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.489-496
    • /
    • 2016
  • Recently, a concern about hollow core precast concrete (PC) slab has been increased as a method to improve the construction ability by reducing the self weight of structures during the construction. Hollow core slab which is known as a typical PC slab in domestic construction of PC building has a problem to put shear reinforcements in the web of element during the production of element in the factory. With regard to this point, recently, tripple ribs slab (TRS) which can be said as a new type of half PC slab system was developed. In TRS, it is possible to place shear reinforcements in PC element during the production of the element in the factory. This paper presents the shear test result of TRS which was done by one point loading test under simple support condition. Test parameters are the presence of cast-in-place (CIP) concrete and the contribution of lattice bars. From the test, it was found that the TRS has sufficient shear capacity to resist the design load and its strength can be predicted by the code equations for general beam. It is recommended to ignore the strength of lattice bar in the calculation of shear strength during the construction since its contribution is too low to be considered when CIP is not casted.

Structural Performance of Reinforced Concrete Beams Strengthened with Sprayed Fiber Reinforced Polymers (Sprayed FRP로 보강된 철근콘크리트 보의 보강성능에 관한 연구)

  • Lee, Kang-Seok;Son, Young-Seon;Lee, Moon-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.421-431
    • /
    • 2007
  • The main purpose of this study is to develop a sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing one of the carbon or glass chopped fibers and one of the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In order to investigate the material property of the sprayed FRP, this study carried out tensile tests of the material specimens, which were changed with the combinations of various variables including the length of chopped fiber and the mixture ratio of chopped fiber and resin. These variables were set to have the equal material strength, compared with that of one layer of the FRP sheet. As a result, the optimal length of glass and carbon chopped fibers was fumed out to be 38 mm, and the optimal mixture ratio between chopped fiber and resin was also turned out to be 1 : 2 from each variable. And also, the thickness of the sprayed FRP to have the equal strength to one layer of the FRP sheet was finally calculated. In is study, a series of experiments were carried out to evaluate the strengthening effects of flexural beams, shear beams and damaged beams strengthened with the sprayed FRP method, respectively. The results revealed that the strengthening effects of the flexural and shear specimens were reasonably similar to those of the FRP sheet, and the developed Sprayed FRP technique is able to be used as a strengthening scheme of existing RC building.

Relay Protocol in DSRC System (DSRC 시스템에서 릴레이 프로토콜)

  • Choi Kwang-Joo;Choi Kyung-Won;Cho Kyong-Kuk;Yoon Dong-Weon;Park Sang-Kyu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.32-39
    • /
    • 2006
  • 5.8GHz DSRC(Dedicated Short Range Communications) is a short to medium range communications service that supports both public safety and private operations in roadside to vehicle and vehicle communication. However the 5.8GHz frequency may cause the shadowing effect or communication blocking problem when there is an obstacle or another vehicle between RSE (Road Side Equipment) and OBE (On Board Equipment). In this paper, to solve this problem of the 5.8GHz DSRC, we propose a relay protocol based on the standard of DSRC radio communication between RSE and OBE in the 5.8GHz band made by TTA (Telecommunication Technology Association). By using the proposed relay protocol to DSRC system and intervehicle communication, we also consider a fixed relay protocol and mobile relay protocol. We expect to apply this relay protocol for the DSRC intervehicle communication and video communication between drivers and safe distance among vehicles in the near future.

Fractional efficiency of Nanomaterials for the High efficiency respiratory filters (고효율 호흡보호구의 나노물질 입경별 제거 효율)

  • Lee, Gwang-Jae;Ji, Jun-Ho;Kim, Won-Geun;Yook, Se-Jin;Kim, Jong-Kyo;Kim, Jung-Ho
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • Controlling exposures to occupational hazards is important for protecting workers. Certified facepiece respirators are recommended when engineering controls do not adequately prevent exposures to airborne nanomaterials. The objective of this study is to carry out the experimental performance test to investigate the fractional efficiencies of the filter media for two grades of facepiece respirators. Experimental performance evaluations were carried out for the test NaCl particles and silver nanoparticles. For media of respirator filter, the penetration of NaCl particles was less than 5% and the most penetrating particle size occurred at about 40 nm. For silver nanoparticles, the most penetrating particle size was about 20nm with higher efficiency than those of NaCl particles. Charge characteristics of airborne nanoparticles is important because the media of respirator filter is made by the electret filter media.

Evaluating Stability and Functionality of Hybrid Erosion Control Dam for Reducing Debris Flow Damage in Forested Catchment Nearby Urban Area (도시생활권의 토석류 피해 저감을 위한 복합형 사방댐의 안정성 및 기능성 평가)

  • Kim, Kidae;Kim, Dongyeob;Seo, Junpyo;Lee, Changwoo;Woo, Choongshik;Kang, Minjeng;Jeong, Sangseom;Lee, Dongkyun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.1
    • /
    • pp.59-70
    • /
    • 2018
  • The objective of this study was to develop erosion control dam for preventing disaster in consideration of characteristics of forested catchment near urban area, and to assess its stability and functionality to see its practicability in the field. Two types of hybrid erosion control dams were developed including debris flow prevention dam by using pillar and float board screen type and debris flow control dam by using groyne. Also, review about their static (sliding, overturning, bearing capacity) and dynamic (member force) stability was carried out. According to the result, most of the assessed items met standard safety level although there were some cases where assessed items were short of stability criteria against impact. Also, after miniature flume experiments based on the developed erosion control dam to prove structure function (material catch, deposit), it turned out the dam decreased flow sediment amount and velocity while increasing sediment-capturing capacity by 3.5 times on average compared to the one controlled without erosion control dam. When function of erosion control dam for forested catchment near urban area is quantified based on future flume experiments in a variety of conditions, the dams can be practically used in the urban area, contribution to effectively reducing debris flow damage.