• Title/Summary/Keyword: 안면골

Search Result 703, Processing Time 0.023 seconds

Effect of Pyrroloquinoline Quinone on Osteoclast Generation and Activity (Pyrroloquinoline quinone이 파골세포의 생성 및 활성에 미치는 영향)

  • Ko, Seon-Yle;Han, Dong-Ho;Kim, Jung-Keun
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.329-336
    • /
    • 2005
  • We examined the effect of PQQ, as a scavenger of superoxide, on osteoclast-like cell formation and on mature osteoclast function. To determine whether PQQ scavenges the superoxide, nitroblue tetrazolium (NBT) staining, which is a method to detect superoxide, was performed on HD-11 cells which are a chick myelomonocytic cell line having tartrate-resistant acid phosphatase (TRAP) activity in response to 1,25-dihydroxyvitamin $D_3\;[1,25(OH)_2D_3]$. Histochemical study of TRAP was also performed on HD-11 cells. PQQ inhibited the TRAP-positive multinucleated cell formation of chicken bone marrow cells was also examined. The addition of 20 ${\mu}M$ PQQ inhibited the formation of TRAP-positive multinucleated cell. When chicken osteoclasts were cultured on dentin slices, treatment of 20 ${\mu}M$ PQQ resulted in a significant decrease in dentin resorption by osteoclasts in terms of total resorption area and number of resorption pits. The present data suggest that PQQ, possibly as a scavenger of superoxide ion, inhibits the osteoclastic differentiation and bone resorption.

AN EXPERIMENTAL STUDY ON THE EFFECTS OF OXIDIZED CELLULOSE COVERAGE ON THE CORTICAL BONY DEFECTS (피질골 골결손부에서 Oxidized Cellulose 피개의 영향에 관한 실험적 연구)

  • Kim, Hoi-Jong;Rim, Jae-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.112-126
    • /
    • 1998
  • In dentistry, bony defects can be formed by cyst, tumor, inflammation, trauma and surgery in maxilla and mandible. If the overlying soft tissue invades and preoccupies the jaw bony defects, regenerated bony tissue same as adjacent bone can not replace whole space of the defects, thus preventing osteogenesis from occurring. Guided bone regeneration(GBR) is based on the prevention of overlying soft tissue from entering the bony defect during the initial healing periods. E-polytetrafluoroethylene(e-PTFE) is one of an effective and widely used barrier membrane for GBR, but it has the disadvantages such as surgical removal and high price. To overcome such disadvantages of e-PTFE, many investigators have proposed various absorbable barrier membranes. Inexpensive oxidized cellulose($Surgicel^{(R)}$) membrane was shown to have potential for use as an absorbable barrier membrane for regenerative procedure and it would not require surgical removal. The purpose of this study is to investigate the absorption periods of oxidized cellulose at the implant site and usefulness as a mechanical barrier, preventing the ingrowth of the overlying soft tissue into the bony defects. Two bony defects were made in each tibia of a dog using drill and one defect covered with oxidized cellulose and the other covered with periosteum directly as control. The experimental animals were sacrificed at 1st-7th, 10th, 14th, 21th, 28th day postoperatively, Inspection of the specimens was done to evaluate gross changes. Specimens were examined histopathologically by hematoxylin-eosin and Masson's trichrome staining under light microscope. The results were as follows : 1. There was no significant differences of inflammatory reaction between the experimental and the control group. 2. The resorption of oxidized cellulose was almost completed within 14th day. 3. Histologically, bone formation in the experimental group was somewhat more than that of the control group at 10th, 14th, 21th and 28th day postoperatively. The bone forming pattern of the experimental group was more regular than that of the control group. 4. There was no evidence of soft tissue invasion into the bony defect in the experimental group. In conclusion, oxidized cellulose membrane might be used as an alternative absorbable barrier membrane to prevent overlying soft tissue invasion into the bony defects.

  • PDF

A Study on the Tissue Response and Bone Formation after Augmentation Using Proplast and Porous Polyethylene in Rabbit Mandible (Proplast와 Porous Polyethylene을 이용(利用)한 가토(家兎) 하악골(下顎骨) 증대술후(增大術後) 조직반응(組織反應) 및 골형성(骨形成)에 관(關)한 연구(硏究))

  • Kim, Geon-Jung;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.101-116
    • /
    • 1989
  • Proplast and Porous Polyethylene which have porous structures as low-modulus polymers have been recently used in maxillofacial plastic and reconstructive surgery. The purpose of this study was to compare the response of adajacent tissue, new bone formation and stability after augmentation by differen methods of subperiosteal graft using proplast and purous polythylene in rabbit mandible. The augmentation procedure was carried out by dividing into two groups, A and B. A group consisted of subperiosteal graft on the cortex, and the other B group was made up only graft following artificial decortication in the mandibular body of rabbit. The experimental animals were sacrificed on the 1st, 2nd, 4th and 8th week after grafting for macroscopic and light microscopic examination. The samples extracted at the 6th postgrafting week were also used for biometric testing and scanning electron microscopic examination. The results obtained from this study were as follows : 1. Macroscopically, infection of graft site, deformation and migration of graft material were not observed in all experimental groups. 2. B group showed more rapid and increased bone formation and the greater stability than A group, and tissue response was similar to each other. 3. In the tissue response, macrophages and cellular infiltrations were observed in Proplast group, but few in PHDPE group. 4. In bone formation of A group, Proplast group showed no bone formation until the 8th week, but PHDPE group showed small quantity of osteoid tissue from the 2nd week and appositional bone growth with new bone formation at the 8th week. 5. In bone formation of B group, both Proplast and PHDPE group showed bone formation, but PHDPE group showed more rapid and larger bone formation. 6. In pattern of bone formation, Proplast group mainly showed appositional bone growth pattern connected with graft site. On the other hand, PHDPE group showed mixed pattern of new bone formation in the pore connective tissue with appositional bone growth from graff site. 7. The maximum mean values of shear stress were serially $111.3gf/mm^{2}$ in PHDPE of B group, $84.8gf/mm^{2}$ in PHDPE of A group, $32.9gf/mm^{2}$ in Proplast B group, and $15.7gf/mm^{2}$ in Proplast of A group. From above results, It was suggested that the capacity of bone formation and stability between bone and graft material were dependent on the pore size and structure of graft material itself, the state of graft site and tissue response.

  • PDF

THE EXPRESSION OF TGF-$\beta$1, IGF-I, BFGF IN DISTRACTION OSTEOGENESIS ACCORDING TO DIFFERENT DISTRACTION RATES IN RABBIT'S MANDIBLE (가토 하악골에서 신연 골형성술시 신연속도에 따른 TGF-$\beta$1, IGF-I, bFGF의 발현)

  • Shin, Sun-A;Jee, Yu-Jin;Song, Hyun-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.3
    • /
    • pp.205-217
    • /
    • 2005
  • Distraction osteogenesis is a technique of lengthening bone including soft tissue by gradual separation of surgically divided bone surfaces. Although the biomechanical, histological, and ultrastructural changes associated with distraction osteogenesis have been widely described, the molecular mechanisms governing the formation of new bone in distracted bone segments remain largely unclear. However, such information has significant clinical implications because it may enable targeted therapeutic manipulations designed to accelerate osseous regeneration. The purpose of this study was to evaluate the expression of TGF-$\beta$1, IGF-I and bFGF in distraction osteogenesis according to different distraction rates in a rabbit's mandible. When twenty-four adult rabbits underwent open osteotomy between the premolar and mental foramen, an external bilateral distraction device was applied. Latency was allowed for five days before distraction. Three different distraction rates were 0.7 mm/day (A, n=8), 1.4 mm/day (B, n=8) and 2.4 mm/day (C, n=8). The distraction device was activated with the same distraction rhythms of twice a day until 4.9 mm (A & B group) and 8.4 mm (C group) length gains was achieved. The animals were sacrificed at postoperative 3, 7, 14 and 28 days. The bony specimens were stained with H&E for histologic examination, and RT-PCR analysis was done for the identification of the expression of TGF-$\beta$1, IGF-I and bFGF. The results obtained from this study were as follows : The 0.7 mm/day and 1.4 mm/day distraction rate groups were shown to improve regenerative bone formation on radiographic and histologic examination. Also, TGF-$\beta$1, IGF-I and bFGF expression increased in the 0.7 mm/day and 1.4 mm/day distraction rate groups. But the 2.4 mm/day distraction rate group specimen was different with adjacent normal bone and hardly expressed of growth factors. These findings suggest that improved new bone formation in the 0.7 mm/day and 1.4 mm/day distraction rates is associated with enhanced expression of TGF-$\beta$1, IGF-I and bFGF by mechanical tension stress. Additionally, the 0.7 mm/day and 1.4 mm/day distraction rate groups were significantly different from the 2.4 mm/day distraction rate group in the expression of growth factors. According to the above results, it seems possible to apply a distraction rate of up to 1.4 mm/day a day in rabbit's mandible. And further studies are needed to evaluate growth factors of TGF-$\beta$1 and IGF-I, which are excellent in expression.

A CLINICAL STUDY ON FIBRO-OSSEOUS LESIONS OF THE JAWS (악골내 섬유조직성-골성병소에 관한 임상연구)

  • Kim, Uk-Kyu;Cha, Seong-Man;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Jong-Ryoul;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.3
    • /
    • pp.248-258
    • /
    • 2005
  • The challenging task of classifying the fibro-osseous(FO) lesions has been previously attempted but only in the past 15 years has the entire spectrum of diversity been appreciated. For the clinicians, it is hard to clearly diagnose the lesions before operations. The purpose of this study was to review the literature about fibro-osseous lesions of the jaws and to analyse our clinical cases. As the results of the review of clinical features, radiography and histopathologic findings of sixteen cases of fibro-osseous lesions, we could elucidate diagnostic aids for treatment of benign FO lesion in jaws. Six patients involving fibrous dysplasia complained the facial swelling and facial asymmetry. The radiographic features of the lesions showed ground-glass radiopacity mostly and the histologic findings showed typically Chinese character-shaped trabeculae without osteoblastic rimming in the fibrous stroma. Six patients with ossifying fibroma were notified as swollen buccal cheek state. Their radiographic findings showed cortical expanded radiolucent lesion with sclerotic defined border, which was contrast to the normal adjacent bone. The lesions showed variant radiolucent lesions. Histological findings were revealed as cellular fibrous stroma with woven bones, variable patterns of calcifications. Three patients with cemental dysplasia didn't have specific complaints. Well circumscribed radiopaque lesions on mandibular molar area were observed. Cementum-like ossicles with fibrous stroma were found on microscopic findings. A osteoblastoma case with jaw pain was found. The radiographic feature was a mottled, dense radiopacity with osteolytic border on mandibular molar area. Under microscopy trabecule of osteoid with vascular network were predominantly found. Numerous osteoblast cells with woven bone were found. These clinical, radiographic and microscopic findings of benign fibrous-osseous lesions would suggest diagnostic criteria for each entity of FO lesions.

Measurement and Algorithm Calculation of Maxillary Positioning Change by Use of an Optoelectronic Tracking System Marker in Orthognathic Surgery (악교정수술에서 광전자 포인트 마커를 이용한 상악골 위치 변화의 계측 및 계산 방법 연구)

  • Park, Jong-Woong;Kim, Soung-Min;Eo, Mi-Young;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.233-240
    • /
    • 2011
  • Purpose: To apply a computer assisted navigation system to orthognathic surgery, a simple and efficient measuring algorithm calculation based on affine transformation was designed. A method of improving accuracy and reducing errors in orthognathic surgery by use of an optical tracking camera was studied. Methods: A total of 5 points on one surgical splint were measured and tracked by the Polaris $Vicra^{(R)}$ (Northern Digital Inc Co., Ontario, Canada) optical tracking system in two cases. The first case was to apply the transformation matrix at pre- and postoperative situations, and the second case was to apply an affine transformation only after the postoperative situation. In each situation, the predictive measuring value was changed to the final measuring value via an affine transformation algorithm and the expected coordinates calculated from the model were compared with those of the patient in the operation room. Results: The mean measuring error was $1.027{\pm}0.587$ using the affine transformation at pre- and postoperative situations and the average value after the postoperative situation was $0.928{\pm}0.549$. The farther a coordinate region was from the reference coordinates which constitutes the transform matrixes, the bigger the measuring error was found which was calculated from an affine transformation algorithm. Conclusion: Most difference errors were brought from mainly measuring process and lack of reproducibility, the affine transformation algorithm formula from postoperative measuring values by using of optic tracking system between those of model surgery and those of patient surgery can be selected as minimizing the difference error. To reduce coordinate calculation errors, minimum transformation matrices must be used and reference points which determine an affine transformation must be close to the area where coordinates are measured and calculated, as well as the reference points need to be scattered.

AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS (Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구)

  • Woo, Jin-Oh;Park, Bong-Wook;Byun, June-Ho;Kim, Seung-Eon;Kim, Gyoo-Cheon;Park, Bong-Soo;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION ACCORDING TO THE THREAD DESIGNS AND THE MARGINAL BONE LOSS OF THE IMPLANTS (임프란트 나사형태와 치조골 흡수에 따른 응력분산의 3차원 유한요소법적 분석)

  • Kim, Il-Kyu;Son, Choong-Yul;Jang, Keum-Soo;Cho, Hyun-Young;Baek, Min-Kyu;Park, Sheung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.60-71
    • /
    • 2008
  • The objective of this study is to evaluate the stress distribution according to the thread design and the marginal bone loss of a single unit dental implant under the axial and offset-axial loading by three dimensional finite element analysis. The implants used had the diameter of 5mm and 4mm with 13mm in length and prosthesis with a conical type which is 6mm in height and 12mm in diameter. The thread designs were triangular, square and buttress. In the three dimensional finite element model with $15\times15\times20mm$ hexahedron and 2mm cortical thickness, implants were placed with crown to root ratio 7:12, 10:9, 13:6 and 16:3. And additionally the axial force of 100N were applied into 0mm, 2mm and 4mm away from the center of the implants. The results were as follows 1. The maximum von-Mises stress in cortical bone was concentrated to cervical area of implant, and in cancellous bone, apical portion. 2. Comparing the von-Mises stresses in cortical bone of 2mm and 4mm offset loading with central axial loading, it were increased to 3 and 5 times in diameter 4mm implant, and 2 and 4 times, in diameter 5mm implant. 3. The square threads were more effective than the triangular and butress as the longer diameter, the offset loading, and the worse crown to root ratio. 4. The von-Mises stresses were relatively stable until crown to root ratio 13:6, but it was suddenly increased at 16:3. From the results of this study, minimum requirement of crown to root ratio of implant is 2:1, and in the respect of crown to root ratio, diameter and offset loading, square threads are more effective than triangular and buttress threads.

Radiographic Bone Density Around Immediately Placed Titanium Implant on the Extraction Socket of Diabetic and Insulin-Treated Rat Maxilla (당뇨쥐 상악에서 발치후 즉시 식립 임플란트 주위골의 방사선 골밀도)

  • Park, Kun-Hyun;Park, Su-Hyun;Lee, Sung-Hwy;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.389-395
    • /
    • 2010
  • Purpose: Although it is generally accepted that patients with controlled diabetes have similar rates of success for dental implants as healthy individuals, the use of dental implants in diabetic patients is controversial. In addition, the impact of diabetes on the healing of bone associated with immediately place dental implants is not completely understood. The purpose of this study was to measure bone response to implants radiologically in uncontrolled and insulin-controlled diabetic rats. Materials and Methods: Twenty rats were divided into control, insulin-treated and diabetic groups. The rats received streptozotocin (60 mg/kg) to induce diabetes; animals in the insulin-treated group also received three units of subcutaneous slow-release insulin. Two titanium implants ($1.2{\times}3$ mm) were placed in the extraction socket of the maxillary first molars of the animals and were harvested at 3 days, 1, 2 and 4 weeks. The bone density was measured by digital radiography using gray-level analysis (histogram) in the regions of interest (ROI) at four points: two mesial and two distal to both sides of the implant. Results: The results showed that the osseointegration of the implants was impaired in the diabetic rats compared to the control and the insulin-treated rats. The radiographic evidence demonstrated marked destruction of bone around the implants in the diabetic group. Both the control and the insulin-treated groups had a significantly higher bone density on radiograph than the diabetic group from the 1 week of the experiment (P<0.05 for each comparison). Conclusion: The present study revealed that the immediate placement of titanium implants in the maxilla of diabetic rat lead to delay in the maturation of bone adjacent to implants. It is expected that the reduced predictability of success of immediate implantation in patient with the uncontrolled diabetes.

Comparative Study on Osseointegration of Calcium Metaphosphate (CMP) Coated Implant to RBM Implant in the Femur of Rabbits (가토의 대퇴부에 Calcium Metaphosphate로 코팅된 임플란트 매식후 골유착에 관한 비교 연구)

  • Kang, Young-Joo;Kim, Ki-Hyun;Lee, Jae-Yeol;Lee, Ju-Min;Ahn, Sang-Wook;Song, Jin-Woo;Jung, Eu-Gene;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.511-520
    • /
    • 2010
  • Purpose: This study was conducted in order to compare the efficacy of osseointegration of three different calcium metaphosphate (CMP) coated implants in the rabbit's femur. Materials and Methods: Twenty four rabbits and three different type of CMP coated implants and RBM implants were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics. Two implants were installed into the condyle of femur of each rabbits. The animals were sacrificed at 2 and 4 weeks after installation. The undecalcified specimens were prepared for histological, radiological examination and histomorphometric analysis of implant-bone contact ratios (BIC) and bone area ratio (BA). Results: Two implants were failed to osseointegrate and implant success rate was 95.2%. There were not any significant inflammatory response in all groups. Fluorescent image at 4 weeks shows that remodeling is slower in RBM group than CMP group. CMP III showed more active remodeling than CMP I, II. In histomorphologic analysis, BIC ratio at 2 weeks was lower than 4 weeks. Conclusion: The results suggest that the ratios of CMP coated implants were higher than that of RBM control group but there is no significantly difference between RBM group and CMP group. In conclusion, CMP coated implant had more clinical availability than RBM implants.