• Title/Summary/Keyword: 안내된 실험

Search Result 250, Processing Time 0.028 seconds

An Analysis of the Authentic Inquiry Components in Science Inquiry Experiments Textbooks Developed Under the 2015 Revised National Curriculum (2015 개정 교육과정에 따른 과학탐구실험 교과서에 나타난 참탐구 요소 분석)

  • Lee, Jaewon;Lee, Kyuyul;An, Jihyun
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.3
    • /
    • pp.183-195
    • /
    • 2019
  • In this study, we investigated the characteristics of the authentic inquiry components in the inquiry tasks of Science Inquiry Experiments textbooks developed under the 2015 Revised National Curriculum. After classifying inquiry tasks by core concepts, we analyzed the cases that students autonomously planned or performed the authentic inquiry components. The results of the study revealed that investigating multiple materials component most frequently appeared in all units. However, generating research question, selecting variables, observing multiple variables and transforming observations components appeared in a few tasks of history and everyday science units as they were often guided or structured in textbooks. Controlling simple or complex variables, observing intervening variables and considering methodological flaws components rarely appeared in all units as most of textbooks did not consider or indicate explicitly. Authentic inquiry components of everyday science unit tended to be handled in small group activities. On the bases of the results, the implications for the development of the inquiry tasks of Science Inquiry Experiments textbooks are discussed.

Design of Tour Guide System using Bluetooth 4.0 and WiFi Sensor Technology (블루투스4.0과 WiFi 센서 기술을 이용한 관광안내 시스템 설계)

  • Kim, Hee-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6888-6894
    • /
    • 2015
  • Bluetooth 4.0 is the most appropriate technology for Internet of Things, which can be used to enhance and expand the existing areas and areas with a variety of applications. In this paper, an example of the services of the Internet of Things, we developed a tour guide system using the Bluetooth 4.0 and WiFi sensor technology. iBeacon-based push service have been limited to iOS smart phone series, non-iOS family and lower version of iOS 6 smart phones can not receive push-based services. This paper proposed in iBeacon and WiFi sensor is more than tourists, while maintaining the existing system (non-iOS smartphone users) can provide the service to you. Service tourist information as well as that can provide the advertising associated with the service. With 10 kinds of smart phones used in Korea was the experiment on the MAC information collected. This experiment is to track the behaviour of tourists in history can provide customized services can be based. Tourist destinations as well as amusement parks, resorts, etc. If you want to apply this system in a crowded place for user behavior information-gathering feature views over the a prevention of a missing child features such as notifications, risk, prevention is possible for a variety of applications.

Older Drivers' Characteristics and Optimal Number of Guide Names on Road Signs (도로표지에 대한 고령운전자의 인간공학적 특성과 적정 안내지명 개수에 대한 연구)

  • Noh, Kwan-sub;Lee, Jong-hak;Kim, Jong-min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.235-242
    • /
    • 2008
  • Due to the lack of judgement in an information processing on road sign, older drivers usually are having a hard time driving than young group. Furthermore, according to increasing in aging population, older drivers in Korea have been growing much faster. That means research for older drivers' characteristics and the number of guide name for road sign should be needed. In accordance with suggestions, this study was carried out the number of guide names for road sign with a variety of ages from the twenties to the seventies. For the sake of this study, statistical verification was conducted to confirm a change of speed, a reading time and a misreading rate with Driving Simulator and Electrooculogram tool. As the results of study, change of speed in the age range has shown that the higher the proportion of age, the lower the rate of velocity. Also reading time in the age range with regression analysis found that the higher the proportion of age, the higher the rate of reading time by 0.106sec. Finally, a binary logistic model was used to find the main factors. As the results, 4 number of guide names for road sign have been the best of them for older driver. The result of this study verified the importance of ideal guide numbers on road sign for older driver and proved itself to be an effective method to determine the road safety for the road signs.

A study on the strategies to lower technologist occupational exposure according to the performance form in PET scan procedure (PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구)

  • Ko, Hyun Soo;Kim, Ho Sung;Nam-Kung, Chang Kyeoung;Yoon, Soon Sang;Song, Jae Hyuk;Ryu, Jae Kwang;Jung, Woo Young;Chang, Jung Chan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.17-29
    • /
    • 2015
  • Purpose For nuclear medicine technologists, it is difficult to stay away from or to separate from radiation sources comparing with workers who are using radiation generating devices. Nuclear medicine technologists work is recognized as an optimized way when they are familiar with work practices. The aims of this study are to measure radiation exposure of technologists working in PET and to evaluate the occupational radiation dose after implementation of strategies to lower exposure. Materials and Methods We divided into four working types by QC for PET, injection, scan and etc. in PET scan procedure. In QC of PET, we compared the radiation exposure controlling next to $^{68}Ge$ cylinder phantom directly to controlling the table in console room remotely. In injection, we compared the radiation exposure guiding patient in waiting room before injection to after injection. In scan procedure of PET, we compared the radiation exposure moving the table using the control button located next to the patient to moving the table using the control button located in the far distance. PERSONAL ELECTRONIC DOSEMETER (PED), Tracerco$^{TM}$ was used for measuring exposed radiation doses. Results The average doses of exposed radiation were $0.27{\pm}0.04{\mu}Sv$ when controlling the table directly and $0.13{\pm}0.14{\mu}Sv$ when controlling the table remotely while performing QC. The average doses of exposed radiation were $0.97{\pm}0.36{\mu}Sv$ when guiding patient after injection and $0.62{\pm}0.17{\mu}Sv$ when guiding patient before injection. The average doses of exposed radiation were $1.33{\pm}0.54{\mu}Sv$ when using the control button located next to the patient and $0.94{\pm}0.50{\mu}Sv$ when using the control button located in far distance while acquiring image. As a result, there were statistically significant differences(P<0.05). Conclusion: From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine. Conclusion From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine.

  • PDF

An Experimental Study for the Performance Analysis of a Vertical-type Wind Power Generation System with a Cross-flow Wind Turbine (횡류형 터빈을 적용한 수직축 풍력발전시스템의 성능평가를 위한 실험 연구)

  • Cho, Hyun-Sung;Chung, Kwang-Seop;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1272-1278
    • /
    • 2014
  • In this experimental study for the current growing offshore wind, a wind tunnel test was conducted to examine the performance of the vertical-type cross-flow wind turbine power generation system. Due to the limited size of the test section of the wind tunnel, the inlet guide vane of the original wind power generation was scaled down to about 1/5 and the turbine impeller diameter was also reduced to 1/2 of the prototype impeller. The number of the impeller blade is another important parameter to the output power of the wind power generation system and the number was varied 8 and 16. From the analysis of the experimental result, the output brake power of the model wind turbine was measured as 278watts with the 16-blade at 12 m/s of the rated wind speed and the rated brake power of the prototype wind turbine is calculated to 3.9kW at the rated operating condition.

An Vision System for Traffic sign Recognition (교통표지판 인식을 위한 비젼시스템)

  • Kim, Tae-Woo;Kang, Yong-Seok;Cha, Sam;Bae, Cheol-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.45-50
    • /
    • 2009
  • This paper presents an active vision system for on-line traffic sign recognition. The system is composed of two cameras, one is equipped with a wide-angle lens and the other with a telephoto lends, and a PC with an image processing board. The system first detects candidates for traffic signs in the wide-angle image using color, intensity, and shape information. For each candidate, the telephoto-camera is directed to its predicted position to capture the candidate in a large size in the image. The recognition algorithm is designed by intensively using built in functions of an off-the-shelf image processing board to realize both easy implementation and fast recognition. The results of on-road experiments show the feasibility of the system.

  • PDF

Ultra-Wide Band Sensor Tuning for Localization and its Application to Context-Aware Services (위치추적을 위한 UWB 센서 튜닝 및 상황인지형 서비스에의 응용)

  • Jung, Da-Un;Choo, Young-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.6
    • /
    • pp.1120-1127
    • /
    • 2008
  • This paper presents implementation of localization system using UWB (Ultra-Wide Band) sensors and its experimental results along with development of context-aware services. In order for precise measurement of position, we experimented various conditions of pitch angles, yaw angles, number of sensors, height of tags along with measuring errors at each installation. As an application examples of the location tracking system, we developed an intelligent health training management system based on context-aware technology. The system provides appropriate training schedule to a trainee by recognizing position of the trainee and current status of gymnastic equipments and note the usage of the equipment through a personal digital assistant (PDA). Error compensation on position data and moving direction of the trainee was necessary for context-aware service. Hence, we proposed an error compensation algorithm using velocity of the trainee. Experimental results showed that proposed algorithm had made error data reduce by 30% comparing with the data without applying the algorithm.

Simulation of Fire Evacuation Induction System Using Smartphone Navigation Application

  • Shin, Dongmin;Jeon, Seongman;Lee, SungPil;Cho, Byungjun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.243-251
    • /
    • 2020
  • This study is intended to verify the efficiency of the information system by using the navigation application in case of fire. In the demonstration scenario simulation, it was assumed that a fire occurred 6th floor in Korea Institute of Industrial Design Promotion located in C city, K province. Eighty juniors students from K University's department of paramedics of science participated. As a result of the experiment, the demonstration simulation using the navigation application showed that the evacuation time was faster than the case of evacuation guidance in a fire situation. The need for a fire prevention system and fire prevention awareness before and after the implementation of the demonstration scenario simulation increased the need for a fire prevention system and fire prevention awareness score after the experiment.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Development of an Error-Type Analysis Frame and Analysis of High School Students' Error-Types in Observation Behavior Using Microscopes (고등학생의 현미경 관찰 활동에 대한 결과 보고 오류 유형 분석틀의 고안 및 오류 유형 분석)

  • Jin, Hyun-Jung;Lee, Il-Sun;Kwon, Yong-Ju
    • Journal of Science Education
    • /
    • v.35 no.2
    • /
    • pp.127-137
    • /
    • 2011
  • The purpose of this study is to develop the analysis frame of reporting observation results by high school students in biology experiments using microscopes and analyze their error types. For this study, five experiments were carried out by 12 high school students in B metropolitan city. Before these experiments, developed the analysis frame of reporting observation results. Tests for checking prior knowledge of students were done and results of each experiment were taken picture of. Using the developed framework, the real results and reported results submitted by students were analyzed. The result of this study shows how students report their observation results and they tend to have difficulty in doing observation activity itself. The ratio of factual reports is low because observation ways and recording ways have not been taught properly. Observation training is needed for observing real results objectively. The improvement in experiment environment is necessary for right observation, not observation for checking based on only results. In addition, the education of ethics in science research focusing on the integrity should be performed. The analysis data of reporting observation result by students can be used as basic data for teachers to plan observation strategies and to have right observation views and ways.

  • PDF