• Title/Summary/Keyword: 안경사용률

Search Result 42, Processing Time 0.024 seconds

Study on the Changes of Ophthalmic Plastic Lens due to Heating (가열에 의한 플라스틱 렌즈의 변화 연구)

  • Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.247-253
    • /
    • 2011
  • Purpose: The changes in properties of plastic lens due to heating was investigated. Methods: Plastic lenses of -2.00 diopter were heated at 60-100$^{\circ}C$, and then changes of refractive power, surface condition and transmittance were examined. Results: It was shown that the changes of lens surface due to heating happened at 70$^{\circ}C$ for 1h, 75$^{\circ}C$ for 10 min and 100$^{\circ}C$ 10 sec, respectively. More serious crack was occurred in high index lens and at higher heating temperature, respectively, and transmittance decreased depending on the extent of the damage on the surface of lens. Conclusions: Heating at temperatures above 70$^{\circ}C$ drives cracks on the surface of lens. Optician should recommend an appropriate lens considering the wearer's working conditions and guide for paying attention when they use eyeglasses.

Development of Stereopsis Test Program for Measurement of Awareness Ratio of Stereoscopic Images (스테레오 영상 인식률 측정을 위한 입체시 테스트 프로그램)

  • Cho, Sung-Jin;Han, Hyeon-Na;Lee, Ho-Dong;Park, Min-Chul
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.329-330
    • /
    • 2011
  • 3D 영상산업이 발전해 오면서 현재 3D 영상으로 가장 많이 사용되는 것이 바로 stereoscopic 영상이다. 이러한 영상은 인간의 뇌를 속임으로써 화면에 비쳐지는 영상이 마치 화면 밖에 위치하는 것 같은 착각을 일으키게 만들어 3D영상을 인식할 수 있게 해준다. 이때 사람이 양안시를 인식하는 문제에 관한 연구는 이미 안경학에서 많은 발전을 이루어 왔지만, 현재 논의의 중점인 3D 양안시력은 평소 사람이 사용하는 양안시가 아닌 3D Display에서 비춰지는 영상을 다양한 방법으로 양쪽 눈에 다른 영상을 인식하게 함으로써 입체를 인식하게 하는 것이며, 이러한 3D 양안시력을 측정하는 방법에 대해서는 기존의 양안시력과는 다른 측정 방법을 적용하여야 한다. 따라서 이 논문에서는 이러한 3D 입체 영상에 대한 입체시를 측정하는 방법에 대하여 제안한다.

  • PDF

The Influence of the Variation of Conic Coefficient of the Front Surface on RMS Spot Diameter (전면의 conic 계수 변화가 착락원 크기에 미치는 영향)

  • Park, Seong-Jong;Ju, Seok-Hee;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.77-83
    • /
    • 2003
  • To investigate the influence of the variation of conic coefficient of the front surface on the RMS SD(Root Mean Square Spot Diameter) in a back focal plane, we use programs which are Cove V and LOSA 2.0. We consider a spectacle lens with back vertex power of -4.00D, diameter of 70 mm, the front surface powers which are 2.00D, 4.00D, 6.00D, and 8.00D, and the indices which are $n_d$=1.498, 1.523, 1.586, and 1.660, respectively. The RMS SD in the back focal plane and the thickness of an aspherical tens having the optimized conic constant are smaller than those of a spherical lens. The RMS SD in the back focal plane decreases as the front surface power decreases. From these results, we determine the optimized conic constant to improve the optical image quality and decrease RMS SD in the back focal plane.

  • PDF

The study to develope of optical glass(LaF, KzFS1, LBO) (광학유리(LaF, KzFS1, LBO) 개발에 관한 연구)

  • Cha, Jung Won;Park, Moon Chan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.19-30
    • /
    • 2000
  • LaF, KzFS1, LBO glass were manufactured successfully by using platinum crucible in LaF and using clay crucible in the KzFS1 and LBO. There was optically transparent and the refractive indexes were measured by minum deviation method of prism. LaF, KzFS1, LBO show that the refrective indexes are $n_d$ = 1.770 in LaF, $n_d$ = 1.603 in KzFS1, $n_d$ = 1.560 in LBO. The transmittance were obtained that LaF has 85%, and KzFS1 has 83% and LBO has 89% in visible range. These glasses have no any absorption spectrum under visible range. Therefore it has no any color.

  • PDF

Fisherface 알고리즘과 Elastic Graph Matching을 이용한 얼굴 인식

  • 이형지;이완수;정재호
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.869-872
    • /
    • 2000
  • 본 논문에서는 K-L 변환을 기반으로 한 Fisherface 알고리즘과 Elastic Graph Matching 방법을 사용하여 보다 효율적인 얼굴 인식 방법을 제안하고자 한다. 즉, 얼굴의 모양 정보뿐만 아니라, 영상 픽셀의 그레이 정보를 동시에 이용할 수 있는 Elastic Graph Matching 방법과 통계학적으로 신호의 차원을 줄일 뿐만 아니라 주위 환경의 변화에 강인한 Fisherface 알고리즘을 효율적으로 결합하고자 한다 본 연구에서는 얼굴을 인식하는 데에 있어서 주로 문제가 되는 광원의 위치에 따른 조도의 변화, 얼굴 표정 변화, 안경 착용 여부 등을 고려한 Yale대학 데이터베이스에 대해 기존의 여러 얼굴 인식알고리즘을 실험 및 비교하였다. 또한, 이들을 효율적으로 결합할 수 있는 인식 알고리즘을 제안함으로써 인식률 및 속도 면에서 비교적 만족할 만한 결과를 얻을 수 있었다.

  • PDF

PECVD를 통해 향상된 SiN/SiO2/ITO 다층박막의 무반사 효과에 대한 연구

  • Choe, Min-Jun;Gwon, Se-Ra;Song, Ae-Ran;Jeong, Gwon-Beom;An, Gyeong-Jun;Baek, Ju-Yeol;Kim, Bu-Gyeong;Jang, Hyeok-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.274-274
    • /
    • 2016
  • 터치스크린패널로 응용하기 위하여 80%이상의 높은 투과도와 낮은 저항이 요구된다. 그 중에서도 무반사 효과 (anti-reflective, AR) 를 크게하여 투과도를 향상시키는 방법으로 나노구조물, 증착시 경사각, 다층박막 방법 등이 연구 개발되고 있다. 단일 박막을 이용하여 무반사 코팅을 하는 경우, 정밀한 굴절률 조절이 어려우며 낮은 반사율 영역의 선폭이 좁은 단점이 있다. 반면, 저/고굴절률 다층박막의 경우 비교적 굴절률 조절이 용이하고 가시광영역 전반적으로 높은 투과도를 가질 수 있다. plasma enhanced chemical vapor deposition (PECVD) 증착법을 이용하여 무반사 효과를 증대시키기 위해 저/고굴절률 다층구조의 박막을 두께조합에 따라 평가하였으며, 가장 널리 사용되고 있는 Sputtering증착법과 비교하여 연구하였다. 제작된 다층박막의 구조는 glass(sub.)/SiN/SiO2/ITO 이며, 무반사 코팅층인 SiN/SiO2층은 각각 PECVD와 Sputtering 증착법을 통해 성장되었고, ITO는 스퍼터링 증착법을 이용하여 동일하게 성장하였다. 그 결과 PECVD 증착법이 Sputtering 증착법에 비하여 가시광영역(400~800nm)에서 더 높은 투과도를 얻게 되었다. 결과의 차이에 대해서 PECVD 증착법과 Sputtering 증착법으로 성장된 SiN, SiO2 박막의 광학적 특성과 물리적 특성의 변화를 spectroscopic ellipsometry (SE), Rutherford backscattering (RBS), atomic force microscopy (AFM) 을 이용하여 비교, 분석하였다.

  • PDF

Changes of the Plastic Lens Properties Caused by Etching of the Coating Films (코팅막 식각으로 인한 플라스틱 렌즈의 특성 변화)

  • Moon, Byeong-Yeon;Hwang, Ki Ju;Lee, Yoon Jeong;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: We investigated the changes of plastic lens after etching of coating films by comparing uncoated lens. Methods: CR-39, middle index and high index lenses of 0 (zero) diopter were etched at $80^{\circ}C$ and room temperature using a coating remover, and then changes of refractive power, transmittance and surface morphology were investigated. Results: There were no differences in refractive power and transmittance between uncoated and etched lenses. The etching rate was similar in both CR-39 and middle index lens, but in the case of high index lens, it was slower and less steady than the others. From the SEM observation of lens surface, etching damage was found out on the surface of etched lens. It was shown the least damage in middle index lens but the most damage in high index lens. Conclusions: If the etching of coating films is demanded on condition that the surface of ophthalmic lenses are not damaged, a using of most adequate coating remover based on lens material should be considered, and a caution for proper etching conditions is required.

Consolidation and Adhesion of Cellulose Nitrate of Folklore Artifacts in the 19~20th Century (19~20세기 생활민속자료에 사용된 셀룰로오스 나이트레이트의 강화와 접착 연구)

  • Oh, Joon Suk;Lee, Sae Rom;Hwang, Min Young
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.459-470
    • /
    • 2018
  • Cellulose nitrates were used for folklore artifacts(ornamental beads and pipes in hatstrings, frames of eyeglasses, ornamental eyeglass cases, headband ornaments, and jeogori buttons) between the 19th and 20th centuries; however, they are susceptible to cracking, crazing, embrittlement, and crumbling due to deterioration. To consolidate and adhere deteriorated cellulose nitrate folklore artifacts, water-soluble acrylic emulsion adhesives were investigated. For consolidation, Plextol D 498, which has the lowest viscosity in low concentrations, was used. In adhesive films whose glass transition temperature(Tg) is lower than room temperature, the tensile stress and modulus decreased and the strain increased; therefore, the flexibility was high. The Plextol D 498 and Plextol D 498 and Dispersion K 52 films maintained their adhesiveness and flexibility after artificial-sunlight-accelerated ageing, and Plextol D 498 and Dispersion K 52 films hardly caused yellowing. Plextol D 498 was the most stable for accelerating ageing. A low concentration of Plextol D 498 emulsion resulted in the best permeability on the surface of cellulose nitrate, compared with other acrylic emulsions. To prevent ornamental hatstrings from cracking, crazing, embrittlement, and crumbling, a Plextol D 498 emulsion was used. After applying low concentrations(1%, 3%) of the emulsion to consolidate the fragments and high concentration to adhere the fragments, the ornamental hatstrings were protected from crumbling by deterioration, and their fragments were well-adhered. To preserve it from deterioration by oxygen and humidity, the treated ornament was sealed with an oxygen-barrier film using a low-humidity oxygen scavenger.

Visual Fatigue Evaluation using Eye-movement Detection for Stereoscopic Video (안구 운동량 검출을 이용한 스테레오 영상의 시각적 피로도 측정)

  • Choi, Sunghwan;Kim, Donghyun;Choi, Jaeseob;Sohn, Kwanghoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.145-148
    • /
    • 2010
  • 본 논문에서는 3차원 스테레오 영상에서의 시각적 피로도와 안구의 운동량과의 상관관계를 도출하고 시각적 피로도 측정 시스템을 제안한다. 제안한 측정 방법은 3차원 스테레오 영상 시청자의 피로도가 누적되었을 때, 안구의 단속성 운동(saccade)이 감소할 것이라는 가정에 기반을 둔다. 액티브 셔터글라스 방식의 3D 안경을 착용한 시청자의 동공을 검출하고 추적하기 위해 적외선 광원 및 적외선 카메라를 이용한다. 획득한 영상에 대해 이진 임계화를 적용하고 타원 피팅을 수행하여 동공의 위치를 검출한다. 피팅된 타원의 이심률과 크기 및 위치를 제한하여 검출 오류를 줄인다. 검출된 동공의 위치를 바탕으로 안구의 단속성 운동량을 측정한다. 실험에는 변이 정도가 크지 않아 편안하게 시청 가능한 스테레오 영상과 과도한 변이를 가져 시청하는데 불편한 영상이 분리되어 사용되었다. 이들 영상에 대해 각각 실험자의 단속성 운동량을 측정하였다. 실험 결과에서 안구의 단속성 운동량이 변이가 큰 영상에서 그렇지 않은 영상에 비해 감소하는 경향이 나타났다.

  • PDF

Implementation of User Gesture Recognition System for manipulating a Floating Hologram Character (플로팅 홀로그램 캐릭터 조작을 위한 사용자 제스처 인식 시스템 구현)

  • Jang, Myeong-Soo;Lee, Woo-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.143-149
    • /
    • 2019
  • Floating holograms are technologies that provide rich 3D stereoscopic images in a wide space such as advertisement, concert. In addition, It is possible to reduce the 3D glasses inconvenience, eye strain, and space distortion, and to enjoy 3D images with excellent realism and existence. Therefore, this paper implements a user gesture recognition system for manipulating a floating hologram characters that can be used in a small space devices. The proposed method detects face region using haar feature-based cascade classifier, and recognizes the user gestures using a user gesture-occurred position information that is acquired from the gesture difference image in real time. And Each classified gesture information is mapped to the character motion in floating hologram for manipulating a character action. In order to evaluate the performance of the proposed user gesture recognition system for manipulating a floating hologram character, we make the floating hologram display devise, and measures the recognition rate of each gesture repeatedly that includes body shaking, walking, hand shaking, and jumping. As a results, the average recognition rate was 88%.