• Title/Summary/Keyword: 아산

Search Result 986, Processing Time 0.022 seconds

Estimation on the Regions of Freshwater Influence using the Seasonal Salinity Data in Asan Bay Coastal Zone (계절별 염분 자료를 이용한 아산만 연안의 담수 영향범위 추정)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kim, Sang-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.219-231
    • /
    • 2008
  • This study analyzes a general pattern of the gate operation at the Asan bay seadikes and its effects on salinity. The coefficient of determination between precipitation and released freshwater from gate operation turns out to be 0.77-0.89. A stratification is not shown in the analysis of the salinity in upper and lower layers at the Asan bay because of strong tidal effects, and the coefficient of determination between runoff and salinity is in the range of 0.49-0.62 except station Daesan 4. Salinity observations from 8 stations show mean and standard deviation are highly correlated (coefficient of determination=0.9936), and both mean and standard deviation are influenced by freshwater. Eventually it is found that stations Asan 2 to 4 and Daesan 1 are within the regions of the freshwater influences.

Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding (아산화동증식 발열에 의한 화재 사례의 분석)

  • Park, Jin-Young;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.54-63
    • /
    • 2020
  • Although fires caused by heat generation due to Cu2O breeding in wire connections are well-known among fire investigators, there are few papers on the analysis and introduction of fire cases by heat generation due to Cu2O breeding. This study analyzed fire statistics caused by heat generation in electrical connections and the phenomena and features of heat generation due to Cu2O breeding. Then, a fire which occurred in the wire connection in a university lab by heat generation due to Cu2O breeding was analyzed in more detail. This fire case could reach a conclusion that heat generation due to Cu2O breeding caused a fire in the wire connection through the fire pattern investigation of fire origin, the visual investigation of wire connection, 3D CT, power-on-test, and stereoscopic microscopy, SEM and EDS analysis.

Estimation of Sediment Yield to Asan Bay Using the USLE and GIS (GIS와 USLE를 이용한 아산만 유입 유사량 추정)

  • Kim, Sang-Min;Park, Seung-Woo;Kang, Moon-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1059-1068
    • /
    • 2003
  • Geographic Information System (GIS) combined with Universal Soil Loss Equation (USLE) was used to estimate the soil erosion of Asan Bay experiment watershed in Korea. Spatial data for each USLE factors were obtained from the Landsat-5 TM remote sensing images and 1/25,000 scale digital contour maps. Sediment yield to Asan Bay was estimated by the sediment delivery ratio and trap efficiency. The estimated sediment yield was compared with observed on the Asan and Sapgyo estuary sub-watershed within Asan Bay experimental watershed for the period from 1981 to 2000. The calculated total annual sediment yields from Asan and Sapgyo estuary sub-watershed to Asan Bay were 5,665tonnes/yr and 6,766tonnes/yr, respectively. The measured sediment yields were 12,937tonnes/yr and 12,395tonnes/yr, respectively on an average.

Investigation of Delirium Occurrence and Intervention Status in Intensive Care Unit at a Hospital and Perception of Delirium by Medical Staff (일 종합병원 중환자실의 섬망 발생 및 중재 현황과 의료진의 섬망 인식 조사)

  • Kang, Yi-Seul;Kim, Soon-Hee;Lee, Min-Jeoung;Lee, Hyo-Jin;Lim, Oak-Bun;Hong, Sang-Bum;Choi, Hye-Ran
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.71-86
    • /
    • 2023
  • Purpose : This study aims to investigate the status of delirium intervention in adult intensive care unit (ICU) patients and the perception of this delirium by medical staff. Methods : This retrospective study involves 185 patients, whereas, a descriptive survey is conducted with 197 medical staff members. Results : The delirium group includes 100 patients (54.1%). The incidence of delirium is 64.9% in the medical ICU, 65.9% in the surgical ICU, 42.4% in the neuro ICU, and 46.5% in the cardiac ICU. The percentages of delirium prevention intervention differs between the two groups: 65.0% in the delirium group and 95.3% in the non-delirium group. The medical staff recognize that delirium is a common problem in the ICU (100.0%) and requires active medical intervention (98.5%). Conclusion : The length of stay at the ICU is longer in the delirium group than in the non-delirium group. It is necessary to standardize delirium prevention and treatment protocols to be equally applicable to all ICU patients.

Seasonal Variations in Seawater Quality Due to Freshwater Discharge in Asan Bay (담수유입으로 인한 아산만 해양수질의 계절적인 변동)

  • Jeong, Yong Hoon;Cho, Min Kyun;Lee, Dong Gi;Doo, Sun Min;Choi, Hyun Soo;Yang, Jae Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.454-467
    • /
    • 2016
  • In order to understand the seasonal characteristics of seawater in Asan Bay, the quality of this water was observed over four seasons form December 2011 to February 2013, and correlations between seawater quality variations and freshwater input were analyzed by a statistical method. The results, based on factor analysis, indicate that the two most important factors in understanding variation are freshwater input (37.7 %) and seawater exchange (24.4 %). Asan-ho and Sapgyo-ho are two major freshwater sources that affect inner (eastern) Asan Bay. Discharged freshwater from the inner bay strongly affects the spatial and temporal distribution of seawater in the bay overall during the summer rainy season. On other hand, water re-suspended from the bottom of the bay overwhelmed the water quality during the dry winter season. In conclusion, seasonal freshwater discharge dominated the water quality of the bay, and, consequently, DIP limited the growth of phytoplankton in the bay.

A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device (호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.215-221
    • /
    • 2019
  • The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.

An Investigative Study on Middle School Students, Parents and Industrial Institutions for the Establishment of Vocational High Schools in Asan Area (아산지역 특성화고 설치에 대한 중학교 학생, 학부모, 산업체의 요구 조사 연구)

  • Lee, Byung-Wook;Ahn, Jae-Young;Lee, Chan-Ju;Lee, Sang-Hyun
    • 대한공업교육학회지
    • /
    • v.39 no.1
    • /
    • pp.1-22
    • /
    • 2014
  • The purpose of this research are to investigate and analyze requests of middle school students, parents and people in charge of human resources of industrial institutions and to suggest implications which are necessary to establish vocational high schools in Asan area. To achieve them, demands, for the establishment of vocational high schools, requests of desirable department, area, etc. which are recognized by middle school students, parents and people in charge of human resources of industrial institutions in Asan-si were surveyed and analyzed. The subjects of the survey were students and parents who were selected from one third grade class out of each of all the middle schools of Ansan-si. Also, for the people in charge of human resources of industrial institutions, industrial institutions including more than 10 employees were firstly sampled and selected. The number of students analyzed is 484, parents 458, industrial institutions 81, the results are as follows. First, among the third graders, there were 18.5% students who wanted to enter vocational high schools and 72.6% students that replied saying they may enter if vocational schools are established in Asan-si. Among them, 8.8% students replied that they will definitely enter. Second, among the parents, 30.8% wanted their children to enter vocational high schools and 76.9% replied that they may enter if vocational high schools are established in Asan-si. Among them, 8.4% replied that their children will enter certainly. Third, people in charge of human resources of industrial institutions replied that they may recruit 98.8 percent of graduates of vocational high schools in Asan area. Among them, they replied that 17.3% will be recruited certainly. For the replies of recruitment time, there were 49.4% of 'within 1 year', 30.9% of 'within 1~5 years' and for working, there were 60.8% of 'mechanical operators and assembly workers' and 31.6% of 'technicians and functional workers'. Fourth, for the most preferred departments when establishing vocational high schools in Asan-si, middle school students wanted hospitality management, parents were for electricity and electronics, industrial institutions replied with vehicle mechanics. By affiliation, more than the half of respondents wanted industrial affiliation. Fifth, for the most preferred departments when establishing vocational high schools in Asan-si, middle school students and parents preferred Onyang-dong, industrial institutions preferred Dunpo-myeon. Results showed that the most desirable areas were in the vicinity of one's own residential area.

Gemological Characteristics of Rubies and Sapphires from Tanzania (탄자니아산 루비 및 사파이어의 보석광물학적 특성)

  • Park Hee-Yul;Sung Kyu-Youl
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.4 s.46
    • /
    • pp.313-323
    • /
    • 2005
  • XRD, XRF, EPMA, FT-IR, and SEM-CL studies were carried out in order to characterize gemological features of corundum from Tanzania. Fluorescence reaction of the Tanzanian corundum to short and long wave ultraviolet rays was weakly detected. Inclusions in Tanzanian corundum are divided into five types, Type I is fluid-rich inclusion, Type II is gas-rich inclusion, Type III is liquid $CO_{2}$ inclusion, Type IV is solid-rich inclusion, and Type V is a mixture of fluid and solid inclusion and daughter minerals. SEM-CL images show twin structure with growth texture, microphenocryst of spinel solid inclusions, massive and growth texture. Ruby and sapphire from Tanzania are distinctly distinguished by concentrations of Fe and Cr, and plotted in the particular field at $Al_{2}O_{3}/100-Cr_{2}O_{3}-Fe_{2}O_{3}$ diagram. According to FT-IR analysis, all corundum specimens from Tanzania showed the similar patterns, and absorption peaks of $455.09\~459.23\;cm^{-1},\;603.15\~611.71\;cm^{-1},\;1509.00\~1655.05\;cm^{-1}\;and\;3436.41\~3468.87\;cm^{-1}$. These distinctive characteristics mentioned above can be used to identify the locality and source of corundum stones from Tanzania.

Nutrient Budget and Dam Effluence in Asan Bay (아산만 내 방조제 배출수와 영양염의 물질수지)

  • Jeong, Yong Hoon;Cho, Min Kyun;Lee, Dong Gi;Doo, Sun Min;Choi, Hyun Soo;Yang, Jae Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.468-482
    • /
    • 2016
  • To understand variations in the seawater quality of Asan Bay over four seasons form December 2011 to February 2013, we applied two methods: an in-situ observation of water quality and a comparison study of nutrient budgets among three parts (No. 1, 2, and 3) of Asan Bay. We found a significantly high nutrient concentration in the central part of the bay (No. 2) in July 2012 both in the mass balance study and in situ observation. We presumed the source of these nutrients to be both benthic effluence from old dam reservoirs and incompletely-treated municipal waste-water. This elevated nutrient concentration in the central part of Asan Bay (No. 2) expended to off-shore area and eventually triggered an intense Chl-a concentration in Asan Bay. Based on this result, we suggest improved waste-water quality control around the drainage area of Asan Bay.