• Title/Summary/Keyword: 아말감

Search Result 108, Processing Time 0.025 seconds

AN EVALUATION OF THE EFFECT OF CALCIUM SULFATE, AMALGAM AND CALCIUM HYDROXIDE IN THE REPAIR OF FURCATION PERFORATIONS (황산칼슘, 아말감 및 수산화칼슘이 치근분지부 천공부위에 미치는 치유효과에 관한 비교 연구)

  • Kang, Chung-Kyu;Roh, Byoung-Duck;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.93-109
    • /
    • 1997
  • Finding a right repair material for furcation perforation is one of the major issues in clinical endodontics. In this experiment, three materials, calcium sulfate, amalgam, and calcium hydroxide were tested for perforated furcation repair. Sixty premolars and molars of five dogs were used. A #4 round bur was used to create the perforation. All experimental teeth were divided into two repair-time groups. One was immediate-repair group, where the perforation was repaired immediately, the other was delayed-repair group, where the perforation was left open for four weeks and then repaired with the same manner as in the immediate-repiar group. All chamber openings were sealed with amalgam and then radiographed. The animals were sacrificed at eighth week following the repair procedure. Radiographic evaluation for furcal bone destruction was done. Histologic evaluation was ranked as 0,1,2,3 according to the inflammation degrees. New bone formation was also recorded. The following conclusions were drawn within the limits of the experimental results: 1. In immediate-repair group, no significant differences existed between the materials. 2. In delayed-repair group, calcium sulfate showed significantly less furcal bone destruction and lower inflammation degree than amalgam.(p<0.05) 3. Overextruded specimens showed more severe inflammation than unextruded specimens. 4. Most of the specimens showed certain degrees of inflammatory reaction and incomplete hard tissue healing. 5. In delayed-repair group, treated group showed less inflammation than untreated control group.

  • PDF

Retrospective Study of Survival Rates According to the Type of Dental Restoration of Proximal Caries in Primary Molars (치과용 수복재료에 따른 유구치부 인접면 수복물의 생존율연구 : 후향적연구)

  • Jih, Myeongkwan;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Restorative dental materials have advanced rapidly, with improved physical properties that improve survival rates. Accordingly, various materials can be selected. Amalgam, composite resin, glass-ionomer cement, and preformed stainless steel crowns have all been used widely for the restoration of dental caries in primary molars. The various dental materials used to treat proximal caries in the primary molars have distinct advantages and disadvantages. However, few studies have examined their survival rates. This retrospective study examined the 2-year survival rates of more than 700 class II restorations of proximal caries in primary molars clinically and radiologically according to the type of restoration. The study results should help in the selection of class II restorations for molars, one of the biggest concerns of pediatric dentists.

Study on the Manufacturing Technique of Steel-Plated Jewel Beetle's Adornment and Gilt-bronze Openwork Remains (철지비단벌레장식금동투조유물의 제작기법에 관한 연구)

  • Yong, Byoung-Ju;Kang, Jung-Moo;Kim, Soo-Ki
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.417-427
    • /
    • 2010
  • This study is to examine the manufacturing technique based on scientific investigation and analysis on Steel-Plated Jewel Beetle's Adornment gilt-bronze openwork remains excavated from No. 100 site at Hwango-dong Gyeongju. As a result of the investigation on the manufacturing revealed that riveting was adopted to connect gilt-bronze openwork plates and steel plates, followed by mercury amalgam plating method and carving of the patterns by means of the dotted line engraving technique. There were some traces on the surface of Jewel Beetle wings that show the use of pins for fixing, which seems to be the result of recycling or processing. The sectional analysis shows the high possibilities that varnishing with lacquer was adopted for wing adhesion, and it was confirmed that varnishing with lacquer was used on the strap pendant plate to prevent corrosion.

A STUDY OF THE MERCURY VAPOR MEASUREMENT DURING AMALGAM REMOVAL (충전(充塡)된 아말감 제거시(除去時) 발생(發生)되는 수은증기량(水銀蒸氣量) 측정(測定)에 관(關)한 연구(硏究))

  • Na, Keung-Kyun;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.85-92
    • /
    • 1984
  • The aim of this study was to examine the influence of the speed of grinding and coolants on mercury vaporization during amalgam removal. Forty amalgam filled stone dies were stored at $37^{\circ}C$ and 100% relative humidity for 7 days prior to the beginning of the mercury vapor experiment and were divided into 4 different groups; In Group I; Used by high speed without coolant & evacuator during amalgam removal. In Group II; Used by high speed with coolant & evacuator during amalgam removal. In Group III; Used by low speed without coolant & evacuator during amalgam removal. In Group IV; Used by low speed with coolant & evacuator during amalgam removal. The amalgam specimens were removed in a 30-second time period and mercury vapor was collected with membrane filter at 27mm from the site of removal and 45 degree above there. Samples in Group II, IV were removed with coolant spray at a flow rate of 30 ml/min with high-velocity evacuator. Mercury vapor collected membrane filter was analysed by Atomic Absorption Spectrophotometer using cold vapor method. The results were as follows; 1. The mercury vapor levels were obtained all of the Groups. 2. The mercury vapor levels of the Group II, IV (with coolant & evacuator) were less than that of the Group I, III (without coolant & evacuator). 3. The highest mercury vapor level recorded during amalgam removal procedure was Group I (used by high speed without coolant & evacuator) and its record was $0.78{\pm}0.09\;mg/m^3$, which exceed the T.L.V. by 15 times. 4. The mercury vapor level of the Group IV (used by low speed with coolant & evacuator) was more than that of the Group II (used by high speed with coolant & evacuator), but its difference was not significant, statistically. (p > 0.05)

  • PDF

A STUDY ON THE BOND STRENGTHS OF LIGHT-CURING GLASS IONOMER CEMENTS TO DENTAL AMALGAM (광중합 Glass Ionomer Cement와 Amalgam의 결합강도에 관한 연구)

  • Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.357-364
    • /
    • 1996
  • The purpose of this study was to asses the shear bond strengths of 3 types of light-curing Glass Ionomer cement to dental amalgam with or without an intermediary agent. 60 amalgam adherent specimens were prepared and aged in water at $37^{\circ}C$ for 3 days. Before bonding, the amalgam surfaces were finished flat on 600-grit silicon carbide paper. 30 specimens among 60 were used for bonding in this condition, and the other 30 were covered with a thin layer of light-curing intermediary agent. Shear bond strengths were measured with universal testing machine (Instron, Model 4301) and statistically processed by ANOVA and t-test. On completion of bond test, the fracture surfaces were examined under light microscope so that the mode of bond failure could be assessed The results were as follows : 1. Bond strength of Fuji II LC group showed the hightest value and was followed by Vitremer, Vitrebond groups (p<0.05). 2. The bond strengths achieved without an intermediary agent were higher than those obtained with intermediary agent (p<0.05). 3. For the specimens bonded with intermediary agent, bond failures occured mostly at the agent-amalgam interface. So, the use of intermediary bonding agent was thought not recommendable at glass ionomer-amalgam interface.

  • PDF

AN EXPERIMENTAL STUDY FOR MICROLEAKAGE OF AMALGAM USING RESIN ADHESIVE LINERS IN PRIMARY MOLAR TOOTH (유구치 아말감 수복물에서 레진 접착성 이장재의 미세 변연 누출에 관한 비교 연구)

  • Kim, Jong-Tae;Choi, Byung-Jai;Lee, Jae-Ho;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.401-414
    • /
    • 1996
  • The purpose of this study was to compare the marginal leakage of resin liner which was used as a liner to amalgam restoration. Control group composed of no liner group, copalite group and experimental group composed of All-bond 2, Vitrebond, Superbond D-liner applied groups were evaluated. Cl.V preparation with a size of $3{\times}2{\times}1.5mm$ on 70 extracted primary molars were made and applied appropriate liners for each groups. After amalgam filling and polishing, polished specimens underwent temperature changed from $5^{\circ}C\;to\;55^{\circ}C$ a thousand times. After thermocycling, specimens were placed in 2% methylene blue dye solution for 72 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a spectroscopy. (${\times}30$) The following results were obtained. 1. Vitrebond, All-bond 2, Superbond D-liner group exhibited a statistically significant lower degree of dye penetration than no liner and copalite group. (Kruskal-Wallis analysis, P<0.05) 2. No liner group and copalite group exhibited a similar degree of dye penetration. (Mann-Whitney analysis, P>0.05) 3. All-bond 2 group exhibited a statistically significant lower degree of dye penetration than Vitrebond group, (Mann-Whitney analysis, P<0.05) Superbond D-liner group also exhibited a lower degree of dye penetration than Vitrebond group but was statistically insignificant. (Mann-Whitney analysis, P>0.05)

  • PDF

Blackening of Inner Glass Surface in Fluorescent Lamps for LCD Backlight (LCD 백라이트용 형광램프의 흑화 현상)

  • Hwang, Ha-Chung;Jeong, Jong-Mun;Kim, Jung-Hyun;Kim, Dong-Jun;Bong, Jae-Hwan;Chung, Jae-Yoon;Koo, Je-Huan;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.481-486
    • /
    • 2008
  • The different degrees of blackening were observed at the inner surface of borosilicate, soda-lime, and aluminosilicate glass tubes having different sodium (Na) contents. The sodium contents ($Na_2O$) within the borosilicate, soda-lime, and aluminosilicate glass tubes were found to be 4%, 14%, and 0.06%, respectively. The degree of blackening was shown to increase as the sodium content within the glass of the fluorescent lamp containing Ne+Ar+Hg gas mixture. Higher degree of blackening was observed from the inner surface of the glass tube coated with $Y_2O_3$. The blackening was found to be originated from the amalgam of $NaHg_2$ generated by the chemical reaction between the mercury ions within the discharge gas and sodium within the glass tube during operation.

A CLINICAL STUDY OF DENTAL AMALGAM RESTORATION -Reasons for replacement and duration of primary restoration- (치과용 아말감 충전의 임상적 고찰 -재충천의 이유 및 기간에 대한 조사보고-)

  • Lee, Chung-Suck;Kim, Kwang-Ju
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.109-114
    • /
    • 1980
  • Ease of manipulation, adequate mechanical properties, long years of experience and economical cost are the factors which have established amalgam as the most widely used material for dental restorations. But amalgam restoration may require replacement because of secondary caries, fracture, "fall-out", dimensional change, tarnish or corrosion etc.. These failures of amalgam restorations seem to arise from failures during operations rather than from the inherent shortcomings of the material itself or of the patient's mismanagement. It is anticipated that notonly number of analgam restoration, but failures will be increase after more extensive utilization of the medical insurance which began in 1977. Then authors think that it would be helpful for the development of better treatment in daily dental practice, to know the duration of amalgam restorations and the reasons for their replacement. The data for this survey was compiled from 2, 856 out-patients of the Department of Dentistry, Ewha Woman's University Hospital from January 1975 to December 1977. 260 cases among 1,718 fillings were studied, of which 205 cases both had a single reason for replacement and recognized the date of the previous filling. The results obtained were as follows; 1. Amalgam fillings were 58. 5 percent of all dental restorative materials. Of these, 15. 13 percent of the amalgam restorations had to be replaced. 2. The first reason for replacement of amalgam restorations was secondary caries (56.10%), the second was fracture (23.80%) and the third was "fall-out" (8.78%). 3. Among those amalgms requiring replacement, 52.2 percent had been in place less than 3 years, 70.7 percent within 5 years and 89.8 percent had been in place less than 10 years. Only 10.2 percent had been in place more than 10 years.

  • PDF

A STUDY ON AMALGAM CAVITY FRACTURE WITH TWO DIMENSIONAL FINITE ELEMENT METHOD I : VARIATION OF THE WIDTH OF CAVITY (아말감 와동의 파절에 관한 2차원 유한요소법적 연구 I : 와동 폭의 변화)

  • Kim, Han-Wook;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.655-669
    • /
    • 1995
  • Restorative procedures can lead to weakening tooth due to reduction and alteration of tooth structure. It is essential to prevent fractures to conserve tooth. Among the several parameters in cavity designs, cavity isthmus is very important. In this study, amalgam 0 cavity was prepared on maxillary first premolar. Two dimensional finite element models were made by serial photographic method and isthmus(1/4, 1/3, 1/2, 2/3 of intercuspal distance) were varied. Three or four-nodal mesh were used for the two dimensional finite element models. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. 1S model was sound tooth with no amalgam cavity. B model was assumed perfect bonding between the restoration and cavity wall. Both compressive and tensile forces were distributed directly to the adjacent regions. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed von Mises stress, 1 and 2 directional normal stress and Y and Z axis translation with FEM software Super SAPII Version 5.2 (Algor Interactive System Co.) and hardware 486 DX2 PC. The results were as :follows : 1. 1S model was slightly different with 1B model in stress distibution. 1S, 2B, 3B, 4B models showed similiar stress distribution. 2. 1S model and four B models showed similiar pattern in Y axis and Z axis translation. 3. 1S model and four B models showed the bending phenomenon in the translation. 4. As increasing of the width of the cavity, experimental group was similiar with the control group in stress distribution. 5. As increasing of the width of the cavity, experimental group was similiar with the control group in Y and Z axis tranlation.

  • PDF

COMPARISON OF THE PHYSICAL PROPERTIES BETWEEN GALLIUM ALLOY AND HIGH COPPER AMALGAM ALLOYS (갈륨합금과 고동 아말감 합금의 물리적 성질 비교)

  • Kim, Hyeon-Cheol;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.278-287
    • /
    • 1998
  • The purpose of this study was to compare the physical properties between high copper amalgam and gallium restorative material. In this study, the specimens for the 4 experimatal groups (Valiant, Valiant PhD, Gallium Alloy GF II. Gallium Alloy GF II triturated with some addition of alcohol) were prepared in the manner of which stated in ADA specification No.1 for amalgam alloy. And then, measured and compared the value of compressive strength. creep, and dimensional change during hardening of each sample. The results were as follows: 1. In the compressive strength, the Valiant-lathe cut type high copper amalgam-had the highest value of strength(p<0.05), and the Valiant PhD-admixed type high copper amalgam-showed the higher value of strength than the Gallium Alloy GF II(p<0.05) but had no significant difference with Gallium Alloy GF II triturated with some addition of alcohol(p>0.05). 2. In the creep. the Valiant PhD showed the highest value of creep (p<0.05), but there was no significant difference between Gallium Alloy GF II and Valiant(p>0.05). 3. In the dimensional change during hardening, no two groups were significantly different at the 0.050 level. 4. There was no significant difference between Gallium Alloy GF II and the same material which was triturated with some addition of alcohol(p>0.05).

  • PDF