Numerical Experimentations on Flow Impact Phenomena for 2-D Wedge Entry Problem (2차원 쐐기형 구조물 입수 시 발생하는 유체 충격 현상에 대한 수치 실험적 연구)

  • Yum, Duek-Joon;Du, Hun;Kim, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3374-3383
    • /
    • 2011
  • In this study, numerical analyses for slamming impact phenomena have been carried out using a 2-dimensional wedge shaped structure having finite deadrise angles. Fluid is assumed incompressible and entry speed of the structure is kept constant. Geo-reconstruct(or PLIC-VOF) scheme is used for the tracking of the deforming free surface. Numerical analyses are carried out for the deadrise angles of $10^{\circ}$, $20^{\circ}$ and $30^{\circ}$. For each deadrise angle, variations are made for the grid size on the wedge bottom and for the entry speed. The magnitude and the location of impact pressure and the total drag force, which is the summation of pressure distributed at the bottom of the structure, are analyzed. Results of the analyses are compared with the results of the Dobrovol'skaya similarity solutions, the asymptotic solution based on the Wagner method and the solution of Boundary Element Method(BEM).

Factor of Safety of Local Instability in Soil Nail Slopes (쏘일네일이 보강된 사면의 국부파괴에 대한 안전율 분석)

  • Koy, Channarith;Kim, Beom-Jun;Jang, Hyun-Ick;Lee, Sang-Rae;Yune, Chan-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.449-456
    • /
    • 2018
  • In this study, a soil nail design method for a stability analysis of local instability with nail reinforced slope was proposed. The failure mechanism of a local instability of slope was studied and a theoretical equation to estimate the stability of slope was developed. Using the developed equation, the stability analysis was performed according to installation conditions of soil nail such as a slope inclination, a thickness of soil layer, a nail inclination, and a nail spacing. Considering those design factors, a sensitivity analysis for each influence factors was conducted. Analysis results showed that the safety factor of reinforced slope with nail was higher than the slope without nail. In addition, the safety factor of slope according to ground condition was increased in the order of dry, saturated, and seepage condition.

Evaluation of Surface Dose for Field-in-Field (FIF) Technique in Breast Radiotherapy (유방암 방사선치료에서 Field-in-Field (FIF) 기법의 조사면 주변 선량 분석)

  • Il-Hoon, Cho;Daehong, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.851-856
    • /
    • 2022
  • The purpose of this study is to confirm the effect of reducing the surface dose around the radiation field in breast cancer radiotherapy using the Field-in-Field (FIF) technique. X-ray was exposed from a linear accelerator (Linac) was used for irradiation, and the surface dose was measured with a glass dosimeter. The source-to-surface distance (SSD) was 90 cm, the field size is 10 × 10 cm2, and the X-ray energy was 6 MV and 10 MV, respectively. The surface dose of the FIF was compared with the dose measured in the physical wedge (PW) and dynamic wedge (DW). Wedge angles of 15° and 30° were used in the PW and DW, respectively. Surface dose was measured at 1 cm, 3 cm, and 5 cm from the center of the field size, respectively. According to the results, FIF showed lower surface dose compared to PW and DW regardless of the energy of the X-ray beam, wedge angle, and dose measurement point. Since FIF could reduce the radiation dose in periphery of the field size in breast cancer treatment, it is expected to be able to reduce the secondary damage caused by the radiation beam as well as to obtain a uniform dose distribution on the target.

Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery (보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가)

  • Park, Byung-Moon;Bang, Dong-Wan;Bae, Yong-Ki;Lee, Jeong-Woo;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.401-406
    • /
    • 2008
  • The aim of this study is to evaluate contra-lateral breast (CLB) surface dose in Field-in-Field (FIF) technique for breast conserving surgery patients. For evaluation of surface dose in FIF technique, we have compared with other techniques, which were open fields (Open), metal wedge (MW), and enhanced dynamic wedge (EDW) techniques under same geometrical condition and prescribed dose. The three dimensional treatment planning system was used for dose optimization. For the verification of dose calculation, measurements using MOSFET detectors with Anderson Rando phantom were performed. The measured points for four different techniques were at the depth of 0cm (epidermis) and 0.5cm bolus (dermis), and spacing toward 2cm, 4cm, 6cm, 8cm, 10cm apart from the edge of tangential medial beam. The dose calculations were done in 0.25cm grid resolution by modified Batho method for inhomogeneity correction. In the planning results, the surface doses were differentiated in the range of $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ for MW, $1.0{\sim}7.9%$, $1.6{\sim}37.4%$ for EDW, and for FIF at the depth of epidermis and dermis as compared to Open respectively. In the measurements, the surface doses were differentiated in the range of $11.1{\sim}71%$, $22.9{\sim}161%$ for MW, $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ for EDW, and 4.9% for FIF at the depth of epidermis and dermis as compared to Open respectively. The surface doses were considered as underestimating in the planning calculation as compared to the measurement with MOSFET detectors. Was concluded as the lowest one among the techniques, even if it was compared with Open method. Our conclusion could be stated that the FIF technique could make the optimum dose distribution in Breast target, while effectively reduce the probability of secondary carcinogenesis due to undesirable scattered radiation to contra-lateral breast.

  • PDF

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

Conservation treatment of the Bonhwa Bukjiri Maaeyeoraejwasang(Rock-Carved Seated Buddha Statue), Korea (봉화 북지리 마애여래좌상의 과학적 보존처리)

  • Kim, Sa-dug;Choi, Joon-Hyun
    • 보존과학연구
    • /
    • s.34
    • /
    • pp.6-17
    • /
    • 2013
  • Bukjiri Seated Rock-carved Buddha of Bonghwa is a rock carved Buddhist Statues on the Two-Mica Granite with mid-size grains. The non-destructive diagnosis on the statues showed that their surfaces had been damaged by exfoliation or granular decomposition and their physical properties are also found to be weak. In addition, the evaluation of slope stability showed that there are the possibility of toppling failure, or planar and wedge failure. So, we have recovered the physical strength and structural stability of rock using the scientific conservation treatment. We also founded that the existing shelter was damaged by the poor ventilation and water leakage. So we constructed it in a way that there is no water leakage while the ventilation is good.

  • PDF

Area storage density in holographic disk memories using rotational, angular, and spatial multiplexing methods in combination (회전, 각, 그리고 공간 다중화 방법을 결합 사용하는 홀로그래픽 디스크 메모리에서의 면적저장밀도)

  • 장주석
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.5
    • /
    • pp.371-376
    • /
    • 2000
  • For multi-hologram recording especially in a dIsk-shaped storage medium. we had studied a simple cost-effective method to unplement the rotational, angular, and ,patial multiplexmg techniques together in order to enhance the area storage density. Holographic storage with both rotational and angular multIplexing was realized by controlling the rderence beam directly with a pair of wedge prisms. whlie the storage WIth spatIal multlplexmg by shIfting the storage medium. In thIS paper \ve show that lhe area storage density of our system is strongly dependent on f numbers of the lenses in the srgnal and reference anns, and also show that the area storage densrly becollles maximal when the f number of the lens in the signal arm is approximately twice as long for a given f number of the lens in the reference emn. e emn.

  • PDF

An Experimental Study on the Flow Characteristics around Wedge Type Structure by Slamming (슬래밍에 의한 쐐기형 구조물 주위의 유동특성에 관한 실험적 연구)

  • Oh, Seung-Jin;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • This paper presents are experimental investigation to figure out slamming impact pressure and flow characteristics of a wedge type structure in free fall. The flow field has been obtained by 2-frame grey level cross correlation PIV(Particle Image Velocimetry) method, the impact presure of free fall structure by a pressure acquisition system apply to Dewetron system. The angles between a model and the free surface are adapted $15^{\circ}$, $25^{\circ}$, $35^{\circ}$ and $45^{\circ}$ respectively. Velocity field of water exit has higher better than water entry. The impact pressure under the bottom of the model ha been appeared higher values at 15 degrees than 45 degrees, and also at P1.

Interpretation of Vertical Electrical Sounding Data in Saltwater Intrusion Area using Geostatistical Method (지구통계분석을 이용한 해수침투지역에서의 전기비저항탐사 자료 해석)

  • Song Sung-Ho;Lee Gyu-Sang;Yong Hwan-Ho;Kim Jin-Sung;Seong Baek-Uk;Woo Myung-Ha
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.59-64
    • /
    • 2005
  • Although experimental analysis for groundwater sample at wells located systematically are very effective to delineate seawater intrusion region at coastal area, this method is restricted in few wells and time. We have conducted electrical resistivity sounding at 30 points in the study areas to analyze the region of seawater intrusion and found the boundary between salt wedge and fresh water lens from the analysis results of geostatistical method using variogram for one-dimensional inversion results. The methodology adopted in this study would be useful for finding the seawater intrusion region and evaluating quantitatively.