• Title/Summary/Keyword: 심장 판막, 기계

Search Result 127, Processing Time 0.039 seconds

Valve Replacement in an Anuric Patient with Chronic Renal Failure - 1 Case Report - (만성 신부전으로 인한 무뇨증 환자에서의 판막치환술 - 1례 보고 -)

  • Kim, Si-Hoon;Kwack, Moon-Sub;Lee, Sun-Hee;Park, Jae-Kil;Jin, Ung
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.588-590
    • /
    • 1999
  • It is now generalized to perform cardiac surgery in the patients with end-stage renal disease. The growing number of patients with chronic renal failure wake us up to the need to prepare for proper management. There are not only the prevalence of coronary artery disease, but also a great amount of valve dysfunction exist in this group. Peritoneal dialysis may be one of the obstacles for cardiopulmonary bypass but it is not a great hindrance in cardiac surgery with careful preparation and well organized perioperative care. The author has performed mitral valve replacement in a 33-year-old anuric female patient with chronic renal failure and severe mitral insufficiency. Preoperatively, the patient was kept in adequate fluid and electrolyte balance using peritoneal dialysis. Peritoneal dialysis continued and regulated according to the laboratory data in this patient during and after the surgery. She recovered well showing an uneventful course and was discharged on postoperative 1 th day.

  • PDF

Left Ventricular Pseudoaneurysm after Surgery for Infective Endocarditis with Annular Abscess - A case report - (판막륜 농양을 동반한 감염성 심내막염 수술 후 발생한 좌심실 가성류 - 치험 1예 -)

  • 황호영;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.273-276
    • /
    • 2003
  • We report a surgical case of 39-year-old male with a pseudoaneurysm of the left ventricle. Four years ago, the patient underwent aortic and mitral valve replacements with mechanical valves and abscess removal for infective endocarditis with annular abscess. Recent echocardiography demonstrated a communication between left ventricle and abscess pocket, and the size of pocket increased further at the follow-up echocardiography. The patient underwent patch closure of the defect between left ventricle and pseudoaneurysm located at the aortomitral fibrous continuity, under the cardiopulmonary bypass and cardioplegia. The postoperative course was uneventful and the patient was discharged on the 9th postoperative day.

A Clinical Experience of Mitral Valve Replacement (승모판막 치환술의 임상적 고찰)

  • 김종원;황수희
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1347-1353
    • /
    • 1996
  • To assess the long-term results of mitral valve replacement, we reviewed our cases of the 374 patients undergoing mitral valve replacement between March 1982 to February 1992 There were 159 male and 215 female and mean age was 37.8 years. There were 24 hospital deaths(6.4%);the most commonly from low cardiac output syndrome(12 deaths). We used 314 mechanical valves and 60 tissue valves. Most of all were anticoagulated with coumadin maintaining target level of 1.5~3.0 INR of prothrombin time. Follow up was 94% complete(2270 patient-years). There were 12 late deaths 3 due to hemorrhage, 3 due to cerebral embolism and 6 from Overall actuarial survival including hospital mortality, was 82.3% after 10 years of operation Linealized rates of late complication events are follows thromboembolism, 1.3% per patient-year; anti coagulant related hemorrhage, 0.5% per patient year. We analyzed the factors of favorable effect to postoperative course were preoperat ve clinical status including NYHA class, first operation, valve apparatus preservating operation technique, not biggest size of prosthetic valve.

  • PDF

Surgical Result of Congenital Mitral Regurgitation in Children (선천성 승모판폐쇄부전증 교정수술의 단기성적)

  • 홍유선;박영환
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.373-377
    • /
    • 1997
  • Between January, 1991 and May 1995, mitral valve repair was undertaken on 32 patients under 15 years for congenital mitral regurgitation. Mean age was 24.0$\pm$26.1 months(range 3 months to 15 years), 16 patients were male and 16 patients were female associated cardiac anomalies were found in 26 patients (81%), and ventricular septal defects were noted in 18 patients(56%). In regards to pathologic findings, there were annular dilatation(n:7), leaflet prolapse(n=18), cleft leaflet(n=5) and restricted valve motion (n=2). The method of repair consisted of annuloplasty(Modif ed Devega type) in 14, repair of redundunt leaflet in 6, closure of cleft in 5, triangular resection in 2 and splitting of papillary muscle in one. There was no operative mortality and two late deaths occurred as a result of heart failure and sepsis. Tro patients required replacement of the mitral valve after 3 months and 7 months respectivehy because of recurrent mitral regurgitation. Actuarial survival was 92.5% at 46 months and actuarial freedom from reoperation was 95% at 12 months and 92.5% at 46 months. Actuarial freedom from valve repair failure was 68% at 12 months and 61.8% at 46 months. Although valve repair failure rate was high, we believe that mitral valve repair should be of rcrred to children because of low mortality and low reoperation rate.

  • PDF

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Measurement of Porcine Aortic and Pulmonary Valve Geometry and Design for Implantable Tissue Valve (돼지 대동맥, 폐동맥의 근위부 기하학적 구조 측정을 통한 판막 구조 수치의 계량화와 판막 도안에 관한 연구)

  • Park, Sung-Joon;Kim, Yong-Jin;Nam, Jin-Hae;Kim, Soo-Hwan;Lee, Chang-Ha;Lim, Hong-Gook
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.602-613
    • /
    • 2010
  • Background: As life expectancy has been increased, the cardiac valve disease has been increased. In past, mechanical valve for valve replacement surgery was used widely, but it has many weaknesses, such as hemorrhage, teratogenic effect caused by warfarin, acute mechanical failure, taking warfarin during life, etc. So, the tissue valve is used widely and researches for durability of tissue valve are in progress. Tissue valves being used are all imported in Korea, and there is a lack of information on its geometry and design. So, we studied the geometry of porcine aortic and pulmonary valve, and tried to suggest theoretical basis for making the aortic and pulmonary valve. Material and Method: We harvested aortic and pulmonary valves of 25 pigs and measured the geometry of valve at fresh and glutaraldehyde (GA) fixed state. In each group, we measured the diameter of the base, diameter of commissure, valve height, commissural height, etc. Also, for making implantable porcine and bovine pericardial valve, we designed the valve stent form, thickness, height, and leaflet size, form, thickness by different size of valve. Result: The aortic and pulmonary valve geometry and ratio were measured in each group. The right coronary cusp of aortic valve and right facing cusp of pulmonary valve was bigger than other cusps and non coronary cusp was smaller than others (RCC: NCC : LCC=1 : 0.88 : 1). Valve height was correlated to the leaflet size. We designed the outer diameter of stented porcine aortic valve from 19 mm to 33 mm and designed stent height and width, using previous measured ratio of each structure, stent thickness, working thickness (for making valve). Also, we designed the size of stent and form for stented bovine pericardial valve, considering diameter of valve, leaflet length, height and leaflet minimum coaptation area. Conclusion: By measuring of 25 pig's aortic and pulmonary valve geometry and ratio, we can make theoretical basis for making implantable stented porcine valve and bovine pericardial valve in various size. After making implantable valve using these data, it is necessary to do in vivo and in vitro researches, furthermore.

Alternative Technique of Aortic Valve Replacement -Implantation of Mechanical Aortic Valve at a Supra-Annular Level- (기계판막을 판륜상연에 위치시킨 대동맥판 치환술)

  • 최종범;이삼윤
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.504-509
    • /
    • 1996
  • When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic valve replacement in patients with friable annulus caused by some lesions, such as endocarditis and degenerative change. We used an alternative technique for the aortic vlave replacement in 4 patients with valve endocarditis, ) patients with degenerative valvular lesion, and 1 with rheumatic valvular disease. Mattress sutures through the annulus were placed with pledgets on the ventricular side of the annulus, whi h resulted in implantation of the prosthesis at a supra-annular level. Mechanical valves of 21 mm or larger were implanted in the supra-annular position in all patients and there was no impeded motion of leaflets during the follow-up period of mean 13.3 mouths. The transvalvular pressure gradient was less than 6 mm Hg in 3 patients and 20 to 40 mm Hg in 5 patients. The supra-annular implantation of mechanical aortic valve using a vertical mattress suture technique may be a useful alternative method of aortic valve replacement for the selected patients with friable or destroyed aortic annulus.

  • PDF

Coronary Blood Flow Disturbance of a Single Coronary Artery in a Patient Undergoing Aortic Valve Replacement - A case report - (단일관상동맥환자에시 대동맥판막 치환술 시행 중 발생한 관상동맥혈류장애의 치험 - 1예 보고 -)

  • Jung, Hee-Suk;Lee, Jae-Won;Jung, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.774-776
    • /
    • 2009
  • A 57-year-old man with dyspnea was transferred to our institution. Echocardiography demonstrated grade III aortic valve regurgitation with a bicuspid aortic valve. The preoperative coronary angiography showed a left single nary artery. Replacement of the aortic valve was performed. Ventricular fibrillation developed during weaning patient of cardiopulmonary bypass after aortotomy repair. An anomalous origin of the coronary arteries is an incidental finding. However, in patients who are undergoing aortic valve replacement, a can significantly complicate the procedure. If this is present, then it is imperative that the clearly identified and the required procedure should be modified to avoid injury to these.

Acceptability of Low Intensity Anticoagulation Therapy after Mechanical Heart Valve Replacement (기계식 인공 심장판막 치환술 후 낮은 강도 항응혈 관리의 적정성에 관한 연구)

  • Kim, Jong-Woo;Rhie, Sang-Ho;Kim, Young-Chun;Yang, Jun-Ho;Jang, In-Seok;Choi, Jun-Young
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.193-200
    • /
    • 2009
  • Background: The long-term administration of oral anticoagulant to the patients with a mechanical heart valve prosthesis is mandatory. However, the appropriate intensity of oral anticoagulant therapy to prevent thromboembolic or hemorrhagic complications is still controversial. We tried to apply low intensity anticoagulant therapy for which the International Normalized Ratios ranged between 1.5 and 2.5, and we analyzed the anticoagulation-related long term outcomes. Material and Method: From January 1992 to December 2002, 144 patients who underwent a single cardiac valve replacement were included in the study, and their ages ranged from 15 to 72 years (mean age: $47.4{\pm}15.1$): there were 49 aortic valve replacements (AVR) and 95 mitral valve replacements (AVR). The patients were followed up monthly or bi-monthly at the outpatient clinic with clinical examinations and measuring the prothrombin time to adjust the International Normalized Ratios (INRs) within the low-intensity target range between 1.5 and 2.5. Result: The follow-up period was 835.3 patient-years (mean: $5.9{\pm}3.5$) and the INRs of 7,706 measurements were available for evaluation. The mean INRs of the aortic and the mitral valve replacement groups were significantly different (p<0.01). All the patients' INRs were within the target range in 61.9% of the measurements. The mean INRs $(2.16{\pm}0.23)$ of the patients with atrial fibrillation, which was found in 30.3% of the patients, were definitely higher than those $(2.03{\pm}0.27)$ measured in the patients with regular rhythm (p<0.01). Thromboembolic episodes occurred in 9 patients with an incidence of 1.08%/patient-year. Major bleeding occurred in 2 patients (MVR) with an incidence of 0.24%/patient-year. The patients who displayed better compliance showed a lower incidence of complications (p=0.000). Conclusion: The anticoagulation therapy with a low-intensity target range after MVR or AVR seems to be effective and feasible, and increasing the patients’ compliance should be done for achieving more effective anticoagulation therapy.