• Title/Summary/Keyword: 심장 박동수

Search Result 186, Processing Time 0.034 seconds

The Motion Artifact Reduction using Periodic Moving Average Filter (주기적 이동평균필터를 이용한 동잡음 제거)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.75-82
    • /
    • 2012
  • The Photoplethysmogram is a similar periodic signal that synchronized to a heartbeat. In this paper, we propose a periodic moving average filter that use similarity of Photoplethysmogram. This filtering method has the average value of each samples through separating the cycle of PPG signal. If there are some motion artifacts in continuous PPG signal, disjoin the signal based on cycle. And then, we made these signals to have same cycle by coordinating the number of sample. After arrange these cycles in 2 dimension, we put the average value of each samples from starting till now. So, we can eliminate the motion artifacts without damaged PPG signal.

The Comparison Study of Early and Midterm Clinical Outcome of Off-Pump versus On-Pump Coronary Artery Bypass Grafting in Patients with Severe Left Ventricular Dysfunction (LVEF${\le}35{\%}$) (심한 좌심실 부전을 갖는 환자에서 시행한 Off-Pump CABG와 On-Pump CABG의 중단기 성적비교)

  • Youn Young Nam;Lee Kyo Joon;Bae Mi Kyung;Shim Yeon Hee;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.184-193
    • /
    • 2006
  • Background: Off-pump coronary artery bypass grafting (OPCAB) has been proven to result in less morbidity. The patients who have left ventricular dysfunction may have benefits by avoiding the adverse effects of the cardiopulmonary bypass. The present study compared early and midterm outcomes of off-pump versus on-pump coronary artery bypass grafting (On pump CABG) in patients with severe left ventricular dysfunction. Material and Method: Ninety hundred forth six patients underwent isolated coronary artery bypass grafting by one surgeon between January 2001 and Febrary 2005.. Data were collected in 100 patients who had left ventricular ejection fraction (L VEF) less than $35\%$ (68 OPCAB; 32 On pump CABG). Mean age of patients were 62.9$\pm$9.0 years in OPCAS group and 63.8$\pm$8.0 years in On pump CABG group. We compared the preoperative risk factors and evaluated early and midterm outcomes. Result: In OPCAB and On pump CABG group, mean number of used grafts per patient were 2.75$\pm$0.72, 2.78$\pm$0.55 and mean number of distal anastomoses were 3.00$\pm$0.79, 3.16$\pm$0.72 respectively. There was one perioperative death in OPCAB group ($1.5\%$). The operation time, ventilation time, ICU stay time, CK-MB on the first postoperative day, and occurrence rate of complications were significantly low in OPCAB group. Mean follow-up time was 26.6$\pm$12.8 months (4${\~}$54 months). Mean LVEF of OPCAB and On pump CABG group improved significantly from $27.1\pm4.5\%$ to $40.7\pm13.0\%$ and $26.9\pm5.4\%$ to $33.3\pm13.7\%$. The 4-year actuarial survival rate of OPCAB and On pump CABG group were $92.2\%,\;88.3\%$ and the 4-year freedom rates from cardiac death were $97.7\%,\;96.4\%$ respectively. There were no significant differences between two groups in 4 year freedom rate from cardiac event and angina. Conclusion: OPCAS improves myocardial function and favors early and mid-term outcomes in patients with severe left ventricular dysfunction compared to On pump CABG group. Therefore, OPCAB is a preferable operative strategy even in patients with severe left ventricular dysfunction.

Effect of Rope-skipping Exercise on the Enhancement of Cardiopulmonary Function (줄넘기 운동 훈련이 심폐기능 항진에 미치는 효과)

  • Hwang, Sang-Ik
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.79-88
    • /
    • 1986
  • In an attempt to observe the effects obtained by the regular physical training, nine soldiers performed regularly the rope-skipping for nine weeks. All subjects were healthy and did not experience any special military training Programs. During the course of the training, their cardiopulmonary functions were measured in the resting and the Post-exercise recovery periods, and the values were compared with ones of the pre-trained. The test exercises loaded to the subjects were rope-skipping and step-rising & falling. The results obtained were as follows: 1) By the training, heart rates decreased very significantly in the resting and post-exercise recovery periods. And the effects began to bring out at the early stage, about the 7th day. 2) As the duration of the training increased, the systolic blood pressures decreased meaningfully in the resting and recovery periods. 3) Only in the early recovery phase after the exercise of the rope·skipping, the respiration rates decreased significantly by the training. 4) The lighter the intensity of the test exercise loaded was, the more prominent the effect of the physical training on the cardiopulmonary functions was. The above results suggest that the 9 week training of the rope-skipping would bring about the enhancement of the cardiopulmonary functions.

  • PDF

Arrhythmia Classification using Hybrid Combination Model of CNN-LSTM (합성곱-장단기 기억 신경망의 하이브리드 결합 모델을 이용한 부정맥 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.1
    • /
    • pp.76-84
    • /
    • 2022
  • Arrhythmia is a condition in which the heart beats abnormally or irregularly, early detection is very important because it can cause dangerous situations such as fainting or sudden cardiac death. However, performance degradation occurs due to personalized differences in ECG signals. In this paper, we propose arrhythmia classification using hybrid combination model of CNN-LSTM. For this purpose, the R wave is detected from noise removed signal and a single bit segment was extracted. It consisted of eight convolutional layers to extract the features of the arrhythmia in detail, used them as the input of the LSTM. The weights were learned through deep learning and the model was evaluated by the verification data. The performance was compared in terms of the accuracy, precision, recall, F1 score through MIT-BIH arrhythmia database. The achieved scores indicate 92.3%, 90.98%, 92.20%, 90.72% in terms of the accuracy, precision, recall, F1 score, respectively.

Case Report of Radiotherapy to a Breast Cancer Patient with a Pacemaker (인공심장박동기가 이식된 유방암환자의 방사선 치료에 대한 사례 보고)

  • Chae, Seung-Hoon;Park, Jang-Pil;Lee, Yang-Hoon;Yoo, Suk-Hyun;Seong, Won-Mo;Kim, Kyu-Bo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • Purpose: In this study, we considerate our radiation therapy process for the breast cancer patient implanted a pacemaker applying the machine movement surgery, shielding, beam selection. Materials and Methods: We perform radiation therapy to a 54 years old, breast cancer patient implanted a pacemaker. The patient underwent a surgery to move the position of a pacemaker to right side breast after consultation with cardiology department. Prescribed dose was 5,040 cGy and daily dose 180 cGy for 28 fractions. The 10 MV photon energy, field size 0/$9.5{\times}20$ cm, half beam and opposing portal irradiation are used. To find out appropriate thickness of shielding board, we carried out an experiment using a solid water phantom ($30{\times}30{\times}7$ cm), a Farmer-type chamber (TN30013, PTW, Germany) and a shielding board (Pb $28{\times}27{\times}0.1$ cm). We calculated expected absorbed dose to te pacemaker with absorb ratio and shielding ratio. In the PTP system (Eclipse, Varian, USA), we figured out how much radiation would be absorbed to the machine with and without shielding. First day of the radiation therapy, we measured head scatter to the pacemaker with MOSFET Dose Verification System (TN-RD-70-W, Medical Canada Ltd., Canada). Results: In the phantom measurement, we found out appropriate thickness was 2 mm of shielding board. In the RTP, when using 2 mm shielding the pacemaker will be absorbed 11.5~38.2 cGy and DVH is 77.3 cGy. In the first day of the therapy, 4.3 cGy was measured so 120.4 cGy was calculated during total therapy. The patient was free from any side effects, and the machine also normally functioned. Conclusion: As the report of association which have public confidence became superannuated, there is lack of data about new machine. We believe that radiation therapy to thiese kind of patients could be done successfully with co-operation, patient-suitable planning, accurate QA, frequent in-vivo dosimetry and monitoring.

  • PDF

The Study of Dose Variation and Change of Heart Volume Using 4D-CT in Left Breast Radiation Therapy (좌측 유방 방사선치료 시 4D-CT를 이용한 심장의 체적 및 선량변화에 대한 연구)

  • Park, Seon Mi;Cheon, Geum Seong;Heo, Gyeong Hun;Shin, Sung Pil;Kim, Kwang Seok;Kim, Chang Uk;Kim, Hoi Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.187-192
    • /
    • 2013
  • Purpose: We investigate the results of changed heart volume and heart dose in the left breast cancer patients while considering the movements of respiration. Materials and Methods: During the months of March and May in 2012, we designated the 10 patients who had tangential irradiation with left breast cancer in the department of radiation Oncology. With acquired images of free breathing pattern through 3D and 4D CT, we had planed enough treatment filed for covered up the whole left breast. It compares the results of the exposed dose and the volume of heart by DVH (Dose Volume histogram). Although total dose was 50.4 Gy (1.8 Gy/28 fraction), reirradiated 9 Gy (1.8 Gy/5 Fraction) with PTV (Planning Target Volume) if necessary. Results: It compares the results of heart volume and heart dose with the free breathing in 3D CT and 4D CT. It represents the maximum difference volume of heart is 40.5%. In addition, it indicated the difference volume of maximum and minimum, average are 8.8% and 27.9%, 37.4% in total absorbed dose of heart. Conclusion: In case of tangential irradiation (opposite beam) in left breast cancer patients, it is necessary to consider the changed heart volume by the respiration of patient and the heartbeat of patient.

  • PDF

Extraction of an Infected Permanent Pacemaker Lead Using Cardiopulmonary Bypass - 2 case reports - (체외 순환을 이용한 감염된 영구 심박동기 도선의 제거 - 2예 보고 -)

  • Oh, Tak-Hyuck;Kim, Gun-Jik;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.86-88
    • /
    • 2010
  • Implanting a pacemaker is the most often used intervention for treating bradycardia. The most commonly used pacemaker is the intracardiac pacemaker, yet it can have many complications. An infected pacemaker can spread to systemic infection and the condition of the patient can quickly get worse, so if an infected pacemaker is suspected, then the pacemaker must be removed. Apart from the use of interventional methods such as a loop or a weight, we can take a more aggressive approach by using extracorporeal circulation for removal of the pacemaker. We report here on two cases in which extracorporeal circulation was used to remove the infected pacemakers.

Wearable Device based Discrimination Algorithm for Dangerous Situation (웨어러블 디바이스 기반 위험상황 식별 알고리즘)

  • Yu, Dong-Gyun;Cho, Kwang-Hee;Hwang, Jong-Sun;Kim, Han-Kil;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.605-606
    • /
    • 2016
  • Recently utilizing various wearable device has been going research to provide new services. Conventional wearable devices provide a service to a user by measuring the biological information. However, by measuring the biometric information such a situation the value of the algorithm, the user state and insufficient technology. In this paper, by utilizing an acceleration sensor and the rate sensor set a threshold for measuring the biological information, and heart rate and movement in order to solve this problem. And it proposes an algorithm to cope with the user's status and identifying emergency situations.

  • PDF

Optimization of 1D CNN Model Factors for ECG Signal Classification

  • Lee, Hyun-Ji;Kang, Hyeon-Ah;Lee, Seung-Hyun;Lee, Chang-Hyun;Park, Seung-Bo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.7
    • /
    • pp.29-36
    • /
    • 2021
  • In this paper, we classify ECG signal data for mobile devices using deep learning models. To classify abnormal heartbeats with high accuracy, three factors of the deep learning model are selected, and the classification accuracy is compared according to the changes in the conditions of the factors. We apply a CNN model that can self-extract features of ECG data and compare the performance of a total of 48 combinations by combining conditions of the depth of model, optimization method, and activation functions that compose the model. Deriving the combination of conditions with the highest accuracy, we obtained the highest classification accuracy of 97.88% when we applied 19 convolutional layers, an optimization method SGD, and an activation function Mish. In this experiment, we confirmed the suitability of feature extraction and abnormal beat detection of 1-channel ECG signals using CNN.

A Study of Optimal Model for the Circuit Configuration of Korean Pulsatile Extracorporeal Life Support System (T-PLS) (한국형 박동식 생명구조장치(T-PLS) 순환회로를 위한 최적화 모델 연구)

  • Lim Choon Hak;Son Ho Sung;Lee Jung Joo;Hwang Znuke;Lee Hye Won;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.661-668
    • /
    • 2005
  • Background: We have hypothesized that, if a low resistant gravity-flow membrane oxygenator is used, then the twin blood sacs of TPLS can be located at downstream of the membrane oxyenator, which may double the pulse rate at a given pump rate and increase the pump output. The purpose of this study was to determine the optimal configuration for the ECLS circuits by using the concept of pulse energy and pump output. Material and Method: Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP) and pump output were collected at pump-setting rates of 30, 40, and 50 BPM. Result: At the given pump-setting rate, the pulse rate was doubled in the parallel group. Percent changes of mean arterial pressure to EEP were $13.0\pm1.7,\; 12.0\pm1.9\;and\;7.6\pm0.9\%$ in the parallel group, and $22.5\pm2.4,\; 23.2\pm1.9,\;and\;21.8\pm1.4\%$ in the serial group at 30, 40, and 50 BPM of pump-setting rates. Pump output was higher in the parallel circuit at 40 and 50 BPM of pump-setting rates $(3.1\pm0.2,\;3.7\pm0.2L/min\;vs.\;2.2\pm0.1\;and\;2.5\pm0.1L/min,\;respectively,\;p=0.01)$. Conclusion: Either parallel or serial circuit configuration of the ECLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration.