• Title/Summary/Keyword: 심실수

Search Result 363, Processing Time 0.025 seconds

Staged Total Correction of Complexes Anomalous Origin of Right Pulmonary Artery from the Ascending Aorta One Case Report (상행 대동맥에서의 우폐동맥 이상기시증을 동반한 복잡 심기형의 단계적 완전 교정술-1례 보고-)

  • 정일상;한재진
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.322-325
    • /
    • 1997
  • We experienced a case of anomalous origin of right pulmonary artery from the ascending aorta associated with pulmonary atresia, ventricular septal defect, absence of left pulmonary artery afld multiple major aortopulmonary collateral artery (MAPCA). At ten month of age, left pulmonary artery creation with unifocalization and right pulmonary artery banding were performed as the Urst stage, followed by coil embolization of right MAPCA 1 month later, and 1 year later, the total correction was done. After total repair, the patient showed good postoperative course and excellent angiographic and hemodynamic results at 1 year follow-up study.

  • PDF

Supra-Arterial Myotomy without Cardiopulmonary Bypass for Myocardial Bridging -One case report- (심폐바이패스없이 관상동맥 심근교의 수술치험 -1례 보고-)

  • 김재현;최세영;유영선;이광숙;윤경찬;박창권
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.181-184
    • /
    • 1999
  • Systolic coronary arterial narrowing, secondary to myocardial bridging which is capable of producing chest pain, myocardial infarction and ventricular fibrillation is a known but an uncommon entity. A supra-arterial myotomy in a case of myocardial bridge causing medication-refractory angina is described. Under the partial sternotomy incision, we performed a supra-arterial myotomy in the left anterior descending coronary artery without cardiopulmonary bypass. The postoperative course was uneventful.

  • PDF

Band-like Annular Pericardial Calcification -A case report - (띠 모양의 윤상 심막 석회화)

  • 조양현;류세민;조종호;손영상;최영호;김요한;김학제
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.452-455
    • /
    • 2004
  • We report a case of a 40-year-old woman whose right ventricular out-flow tract was moderately obstructed by a heavily calcified pericardial ring. It was passing over the base of pulmonary artery and mid-portion of left ventricle but the other parts of the pericardium was mildly fibrotic. The pericardium and calcified ring were completely removed under cardiopulmonary bypass. The patient was recovered uneventfully and we could not find the specific cause of calcified pericardial ring.

Risk Factor Analysis for $SaO_2$ Instability after Systemic-pulmonary Shunt (전신-폐 단락술 후 산소포화도의 불안정성의 위험인자 분석)

  • Jung Sung-Ho;Yun Sok-Won;Park Jung-Jun;Seo Dong-Man;Kim Young-Hwue;Ko Jae-Kon;Park In-Sook;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.277-283
    • /
    • 2005
  • Arterial oxygen saturation $(SaO_2)$ instability frequently takes place after systemic-pulmonary shunt without shunt occlusion. We analyzed actual incidence and risk factors for $SaO_2$ instability after shunt operations, and possible mechanisms were speculated on. Material and Method: Ninety three patients, who underwent modified Blalock-Taussig shunt from January 1996 to December 2000, were enrolled in this study. Adequacy of shunt was verified in all patients, either by ensuing one ventricle or biventricular repair later on or by appropriate pulmonary artery growth on postoperative angiogram. Age, body weight, hemoglobin level at operation were 3 day to 36 years (median: 1.8 months), 2.5kg to 51kg (median: 4.1kg) and $10.7\~24.3$ gm/dL (median: 15.2 gm/dL) respectively. Preoperative diagnoses were functional single ventricle with pulmonary stenosis or atresia in 39, tetralogy of Fallot in 38 and pulmonary atresia with intact ventricular septum in 16. Pulmonary blood flow (PBF) was maintained pre-operatively by patent ductus or previous shunt in 64 and by forward flow through stenotic right ventricular outflow tract (RVOT) in 29. $SaO_2$ instability was defined as $SaO_2$ less than $50\%$ for more than 1 hour with neither anatomic obstruction of shunt nor respiratory problem. Result: 10 patients $(10.7\%)$ showed $SaO_2$ instability after shunt operation. After shunt occlusion was ruled out by echocardiogram, they received measures to lower pulmonary vascular resistance (PVR), which worked within a few hours in all patients. Risk factors for $SaO_2$ instability included older age at operation (p=0.039), lower preoperative $SaO_2$ (p=0.0001) and emergency operation (p=0.001). PBF through stenotic RVOT showed marginal statistical significance (p=0.065). Conclusion: $SaO_2$ instability occurs frequently after shunt operation, especially in patients with severe hypoxia pre-operatively or unstable clinical condition necessitating emergency operation. Temporary elevation of pulmonary vascular resistance is a possible mechanism in this specific clinical setting.

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.

Redo CABG Through a Transabdominal Approach - A Case Report - (경복부 접근법을 통한 관상동맥우회술의 재수술 - 1 례 보고 -)

  • 김홍관;김기봉
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.553-555
    • /
    • 2002
  • Transabdominal approach in redo coronary artery bypass grafting(CABG) may avoid the risk related to repeat sternotomy. Redo CABG using this approach can be performed safely in selected cases. We report a case of redo off-pump CABG through a transabdominal approach in a 59-year-old woman with recurrent unstable angina after a previous CABG. Through a curvilinear epigastric incision, right gastroepiploic artery(RGEA) was harvested as a graft, and the RGEA-to-right coronary artery anastomosis was performed on the beating heart. A 1-day postoperative angiographic study showed the patent RGEA graft, and she was discharged on postoperative 4th day without any complication.

Cardiac Function Changes According to the Type of Operation for Mitral Regurgitation (승모판막폐쇄부전증의 수술술식에 따른 심기능의 변화에 관한 연구)

  • 김진희;김종원;정성운
    • Journal of Chest Surgery
    • /
    • v.34 no.1
    • /
    • pp.51-56
    • /
    • 2001
  • 배경: 이상적인 판막의 개발이 있기 전에는 가능하다면 원래의 판막을 보수하는 것이 좋을 것이라는 생각이 당연하며 실제 임상연구가들은 기술적으로 가능하다면 판막재건술이 판막치환에 비해 대단히 좋은 임상경과를 취한다고 보고하고 있다. 그러나 판막 치환례에서 수술성적과 임상성적이 오히려 좋게 나타나는 경우 이유가 있을 것이고 그 근본원인은 심실의 기능에 따라 좌우되리라는 가설 하에 이를 규명하고자 하였다. 대상 및 방법: 순수승모판막폐쇄부전증으로 수술 받은 40명의 환자를 대상으로 하여 고전적 판막 치환술을 시행한 12례를 1군으로, 후엽을 보전한 18례를 2군으로 그리고 성형수술을 시행한 10례를 3군으로 나누어 수술전의 심에코 소견을 포함하여 입원시에 시행한 전신상태와 수술 후 4주 이내에 시행한 심에코도의 각종 지표를 시행하였다. 결과: 일반적인 환자의 상태변화로는 1군에 비해 2군, 3군에서는 더 나은 결과를 보였으나, 통계적인 차이는 발견할 수 없었다. 뉴욕 심장협회의 분류에 따라서는 수술전보다 많은 호전이 보였으나 세군간의 유의한 차이는 발견할 수 없었다. 심에코도에 따른 심기능을 비교한 바에 의하면 1군에서는 오히려 나빠졌으며 2군, 3군에서는 수술직후에는 술전에 비해 별 차이가 없으며 회복후에는 모든 지표에서 의미있는 호전을 발견할 수 있었으나, 구별분획에 있어 두 군간에는 수술전, 수술후, 회복후의 상호간의 통계적으로 의미 있는 차이는 발견되지 않았다. 결론: 심기능의 차이가 나므로 승모판막폐쇄부전증에 대한 수술로는 가능한한 판막 성형술이 좋고, 판막 성형술이 불가능한 변형이 많은 경우 판엽 일부를 보전이라도 하는 것이 좋다.

  • PDF

Myocardial Abscess with Coronary Artery Occlusion -One Case Report (우관상동맥 폐색을 초래한 심근 농양 -1례 보고-)

  • 이재익;김기봉
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.823-826
    • /
    • 1997
  • Myocardial abscess usually occurs as a complication of infective endocarditis or overwhelming septicemia. Coronary artery occlusion caused by myocardial abscess has been rarely reported. A 61-year-old man presented with fever and chill that developed 6 weeks prior to admission. He had a history of cardiopulmonary resuscitation for ventricular fibrillation and cardiac arrest 4 weeks prior to admission. Echocardiography showed a 3xfcm sized mass in the area of the right atrioventricular groove and coronary angiography showed complete occlusion of the proximal right coronary artery. Under the diagnosis of myocardial infarction complicating myocardial abscess, debridement of abscess and coronary artery bypass grafting with right internal mammary artery to distal right coronary artery was performed. Culture from the abscess cavity demonstrated Salmonella arizona.

  • PDF

Selective Volume Rendering Using Global Shape Information (전역적 형태정보를 이용한 선택적 볼륨렌더링)

  • Hong, Helen;Kim, Myoung-Hee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.10
    • /
    • pp.3280-3289
    • /
    • 2000
  • In this paper,we propose a novel technoque of improving volume rendering quality and speed by integrating volume data and global shape information together. The selective volume rendering method is to generate distance transformed volume using a distance transform to determine the minimum distance to the neaest intercsting part and then render it. The shape information prevents from object occlusions come from similar intensity of each object. Thus it provides effective visual results that enable to get a clear understanding of complex structures. We show the results of selective volume rendering method for left ventricle and right ventricle ans well as the results of selective sampling methods depending on the interpolation from EBCT cardiac images. Our method offers an accelerated technique to accurately visuahze the surfaces of devined objects segmented from the volume.

  • PDF

The changes of electrocardiography and signal-averaged electrocardiography after surgical repair of Tetralogy of Fallot (활로씨 4징의 교정 수술 후 심전도와 신호 평준화 심전도의 변화)

  • Seo, Hye-Eun;Lim, Hae-Ri;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.462-468
    • /
    • 2007
  • Purpose : The purpose of this study was to analyze the changes of the late potential of Signal- averaged electrocardiography (SAECG) and Electrocardiography (ECG) parameters during follow up of those who had taken surgical repair of Tetralogy of Fallot (TOF). Methods : Nine patients who had taken surgical repair of TOF since 1985 checked SAECG and standard 12 leads ECG twice in 1999 and 2005 in Kyungpook national university hospital. We evaluated changes of QRS duration, QT interval and JT interval, QRS dispersion, QT dispersion and JT dispersion of standard 12 leads ECG and Filtered QRS (f-QRS), High frequency low amplitude potential (HFLA), Root mean square in terminal 40 ms (RMS) and Mean voltage in terminal 40 ms (MV) of SAECG between in 1999 and 2005. Results : There were significant decrease of JT dispersion ($101.11{\pm}50.11$ vs $71.11{\pm}22.61ms$, P< 0.05) and significant increase of HFLA ($24.67{\pm}13.19$ vs $32.89{\pm}14.21ms$, P<0.05). But there were no significant changes in other parameters. Conclusion : In repaired TOF patients, we evaluated ECG and SAECG to detect possible late complications such as tricuspid regurgitation, right ventricular enlargement, ventricualar arrythmia and sudden death. And there were significant changes of ECG and SAECG in some parameters (JT dispersion, HFLA). But to see the relationships between the changes of these parameters and the long term prognosis, we need to check more patients and longer follow-up.