• Title/Summary/Keyword: 심미 치과학

Search Result 859, Processing Time 0.026 seconds

THE COMPARISON OF POLYMERIZATION OF COMPOSITE RESIN INFLUENCED BY CURING DEPTH AND SHADE (광중합 복합레진의 색상과 깊이에 따른 중합도의 비교)

  • Choi, Kung-Ho;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.280-289
    • /
    • 2004
  • Adequate polymerization is a crucial factor in obtaining optimal physical properties and clinical performance of resin composite restorative materials. The purpose of this study was to determine the effectiveness of shade and depth on dental composite resin polymerized with plasma arc curing unit employing FTIR and microhardness. From this experiment, the following results were obtained : 1. The light transmission and microhardness by mode 6 in plasma arc curing were similar to by 20 secs in halogen light curing. 2. The experimental groups of A1, A2, A3, A3.5 were not signifcant difference to light transmission and microhardness on surface and 2mm depth, but were significant difference on 3mm and 4mm depth. Especially light transmission and microhardness were small in darker shade and deeper thickness. 3. Compared with depth cure, uncured monomer amount increased at more than 2mm depth. 4. The light transmission by FTIR and polymerization by microhardness were significant corelation.

  • PDF

Survey of the Preferred Vertical Lip-Chin Ratio (상순과 턱의 수직 비율(vertical lip-chin ratio)에 대한 선호도 조사)

  • Kwon, Seong-Jun;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.408-416
    • /
    • 2004
  • The purpose of this study was to investigate the preference of Vertical Lip-Chin Ratio (=Sn-Stm/Stm-Me', hereafter VLCR) in Koreans. The assessors consisted of 44 dentists (male 22, female 22) and 430 lay persons (male 303, female 127). The survey was performed using a questionnaire asking the order of preference. The profiles presented in the questionnaire were based on the profiles of two males and two females, each morphed according to the VLCRs of 1/1.8, 1/1.9, 1/2.0. 1/2.1, 1/2.2. The results were as follows: The difference between males and females. and the difference betwwen dentists and lay persons in the preference of VLCR were not statistically apparent. The most Preferred VLCR was 1/1.9, and the least preferred VLCR was 1/2.2, These results Indicate that the preferred VLCR is smaller than the previously reported VLCR ratios based on the cephalometric evaluation of samples with favorable facial esthetics.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Patients satisfaction for implant supported overdenture with small diameter implant (작은 직경 임플란트를 이용한 임플란트 지지 피개의치에 대한 환자 만족도 조사)

  • Lee, Sang-Yeup;Choi, Dae-Gyun;Paek, Jang-Hyun;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.29-37
    • /
    • 2011
  • Purpose: In cases when implant supported overdenture is made by using standard size implant, additional procedure such as bone surgery and bone grafting can be required. And it gives burden to doctor and patient in terms of cost. Therefore, it is necessary to find the implant therapy for the edentulous patients in making denture with accordable cost and simple procedure. Materials and methods: Edentulous patients with upper and lower dentures participated in this study. Before the operation, survey about patient's satisfaction to the existing dentures was carried out. Surgical procedures included four small diameter implants installation anterior area and immediate loading. One and three month after the procedure, the same survey about patient's satisfaction was carried out, and radiography was taken. Results: We are doing research to the nine patients. Survival rate is 97.2 percent. The comparison of patient's satisfaction before and after surgery is performed based on oral health impact profile 49. We analyze mainly with masticatory discomfort, retention, aesthetics, social problem, psychological discomfort problems. As a result, satisfaction level is increased at all factors. Retention is the most increased satisfactory factor followed by mastication difficulty, pronunciation, psychological discomfort, social discomfort, aesthetics in order. Marginal bone loss is 0.21 mm at 12 weeks after implant placement. Conclusion: This research reveals that the denture supported by mini dental implant increases patient's satisfaction. This study will be continued with more patients for a long time and we are scheduled for taking additional radiography to check whether peri-implant bone resorption occurs or not.

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (심미수복 재료의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Hun-Ju;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.190-201
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution. The brands studied were Charmfil, Charmfil flow(composite resin), Compoglass F and PrimaFlow(compomer). The results were as follows: 1. The mass loss were not significantly different among the materials(p>0.05). 2. The sequence of the degree of degradation layer depth was in descending order by Compoglass F, PrimaFlow, Charmfil, and Charmfil flow. There were significant differences between Compoglass F and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Charmfil flow, Charmfil, PrimaFlow, and Compoglass F. There were significant differences among these materials(p<0.05). 4. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Comfoglass, PrimaFlow Charmal, and Charmfil flow. There were significant differences among these materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.602, p<0.05) Vicker's hardness number and maximum wear depth (r=0.501, p<0.05) were relatively high. These results indicate that wear and hydrolytic degradation may be considered to be evaluation factors of composite resins and compomers.

  • PDF

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

Change in arch width in extraction vs nonextraction treatment (발치 및 비발치 치료 전후 악궁 폭경의 변화)

  • Jeon, Ji-Yun;Kim, Su-Jung;Kang, Seung-Goo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.65-72
    • /
    • 2007
  • Objective: This study was performed to investigate the influences of extraction and nonextraction treatment on smile esthetics by measuring dental arch width changes. Methods: Pretreatment and posttreatment study models of 30 first premolar extraction cases and 30 nonextraction cases were randomly selected to determine whether extraction treatment results in narrow dental arches, and a consequent unaesthetic smile. Arch widths were measured from the cusp tips of the canines and the first molars. Posterior arch widths were also measured at a constant arch depth derived by averaging randomly chosen nonextraction models. Results: The intercanine widths increased significantly in the extraction sample, whereas the intermolar widths decreased significantly. The arch width at a standardized arch depth was significantly wider in the extraction subjects. Conclusion: These results elucidate that constriction in arch width is not a materialized consequence of extraction treatment. It leads to postulate that an esthetically compromising effect from narrow dental arches on smile is hardly anticipated with extraction treatment.

THE STUDY ON THE ORTHODONTIC PATIENTS WHO VISITED DEPARTMENT OF PEDIATRIC DENTISTRY, CHONNAM NATIONAL UNIVERSITY HOSPITAL (전남대학교병원 소아치과에 내원한 부정교합 환자에 관한 연구)

  • Yang, Kyu-Ho;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.113-121
    • /
    • 2000
  • This study was aimed to provide an epidemiologic study so that we could accommadate their orthodontic needs adequately and to obtain the reliable quantitative information regarding the characteristics of orthodontic patients who visited the Department of pediatric dentistry, Chonnam National University Hospital from 1986 to 1999, October. The results were as follows. 1 The total number of orthodontic patients were 1,381(male 658, female 723) and the number of annual patients showed irregular trend and the number of male were slightly higher than that of female. 2. According to the investigation made by age group, the group of under 5 years, 6 to 7, 8 to 9, 10 to 11, 12 to 13 and above 14 years showed 8.4%, 29.6%, 34.3%, 21.2%, 5.7% and 0.8%, respectively. 3. The patients corresponding to primary dentition were 15.7% of total patients and mesial step, distal step and flush terminal plane were 83%, 4.6% and 12.4% respectively. By the way 82% of mesial step had anterior crossbite at the same time. 4. The patients corresponding to Angle classification were 84.3% of total patients and Class I malocclusion, Class II div. 1, Class II div. 2 and Class III was 34.7%, 34.6%, 2.1% and 28.6%, respectively.

  • PDF

A longitudinal study on the interrelationship between the growth change of the gonial ang1e and IMPA. (성장기 아동에 있어 gonial angle의 변화와 IMPA 변화에 관한 누년적 연구)

  • Chung, Chin Su;Ryu, Young-Kyu;Sohn, Byung-Wha;Kim, Young-Joon
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.435-443
    • /
    • 1999
  • This study was undertaken to investigate the growth change of genial angle and interrelationship between the growth change of gonial angle and IMPA in the longitudinal data from 7 years to 15 years. By analyzing the serial lateral cephalograms or 15 males and 19 females of 7 years old to 15 yens old who had no abnomality in growth and development and no history of orthodontic treatment, the following conclusion were obtained. 1. Genial angle gradually decreased with aging in 25 children and in 9 children increased or maintained. 2. There was a tendency that children who decreased genial angle with aging showed gradual increase of IMPA and children who increased or maintained gonial angle with aging showed decrease of IMPA. 3. There was a tendency that regardless of the change of gonial angle, interincisal angle decreased with aging.

  • PDF

CEPHALOMETRIC ANALYSIS FOR CHILDREN WITH NORMAL OCCLUSION IN THE PRIMARY DENTITION (정상교합을 가진 유치열기 아동의 두부방사선 계측학적 연구)

  • Suh, Moon-Sun;Son, Heung-Kyu;Baik, Hyung-Sun;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.109-118
    • /
    • 2005
  • In the field of pediatric dentistry, comparison and analysis of cephalogram values of children are important fir evaluation of growth and development, and are essential to evaluate the craniofacial form and growth pattern for early diagnosis of malocclusion. For this, cephalographic norm values are important, but not many studies on the primary dentition exist. To compare the past norm values of normal occlusion in the primary dentition with current norms, preschool children, 4 to 5 years of age, with normal occlusion in the primary dentition who visited our hospital were examined. Among these children, 46 children with normal facial form and developmental status were chosen for evaluation of cephalogram values. The following results were as follows: 1. For skeletal values, the angular values showed no significant differences between males and females, and the linear values were generally greater in males than females. 2. SNA was $81.3^{\circ}$, SNB was $76.6^{\circ}$ and ANB difference was $4.7^{\circ}$. 3. The ratio for Mandibular body length to Anterior cranial base length was 0.9 : 1 for both male and female and the ratio for posterior facial height to anterior facial height was 61.4 % for male, 62.0 % for female. 4. For dental values, IMPA was $84.2^{\circ}$ and UA to SN was $90.8^{\circ}$. 5. The upper lip to Ricketts esthetic line was positioned 2.6 mm anteriorly, and the lower lip to Ricketts esthetic line was positioned 2.5 mm anteriorly.

  • PDF