• Title/Summary/Keyword: 실험적 설계변경

Search Result 226, Processing Time 0.026 seconds

Development of seam tracking sensing system for welding environment with wall (벽이 있는 용접 환경을 위한 용접선 검출 시스템 개발)

  • Park, Young-Kyun;Byun, Kyung-Seok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • Both ends of welding line are often closed by wall in the welding of ship blocks. In this research, seam tracking sensing system for butt welding in the condition with wall was developed. Seam tracking sensing system measures position of carriage from wall and detects root-pass of welding line. The system consists of the laser displacement sensors and ultrasonic sensors. The laser displacement sensor reciprocal1y rotates by the motor and measures a distance from laser sensor to the welding material. The ultrasonic sensor measures a distance between welding system and walls. The distance measured by the ultrasonic sensor is used to get X(driving) position and to determine initial and end point of the weld line. Y(weaving) and Z(height) of the weld line are obtained by the distance measured by the laser displacement sensor and the orientation of the sensor. The sensing system includes the controller that is independent from the welding carriage. The seam tracking sensing system is attached to both side of welding carriage so that interference between welding torch and sensing system can be avoided during the welding. And both side sensing system minimize dead zone. Finally, developed sensing system was adhered to welding carriage and verified usefulness by experiments.

Design and Implemention of Real-time web Crawling distributed monitoring system (실시간 웹 크롤링 분산 모니터링 시스템 설계 및 구현)

  • Kim, Yeong-A;Kim, Gea-Hee;Kim, Hyun-Ju;Kim, Chang-Geun
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • We face problems from excessive information served with websites in this rapidly changing information era. We find little information useful and much useless and spend a lot of time to select information needed. Many websites including search engines use web crawling in order to make data updated. Web crawling is usually used to generate copies of all the pages of visited sites. Search engines index the pages for faster searching. With regard to data collection for wholesale and order information changing in realtime, the keyword-oriented web data collection is not adequate. The alternative for selective collection of web information in realtime has not been suggested. In this paper, we propose a method of collecting information of restricted web sites by using Web crawling distributed monitoring system (R-WCMS) and estimating collection time through detailed analysis of data and storing them in parallel system. Experimental results show that web site information retrieval is applied to the proposed model, reducing the time of 15-17%.

Theoretical Study on Optimal Conditions for Absorbent Regeneration in CO2 Absorption Process (이산화탄소 흡수 공정에서 흡수액 최적 재생 조건에 대한 이론적 고찰)

  • Park, Sungyoul
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1002-1007
    • /
    • 2012
  • The considerable portion of energy demand has been satisfied by the combustion of fossil fuel and the consequent $CO_2$ emission was considered as a main cause of global warming. As a technology option for $CO_2$ emission mitigation, absorption process has been used in $CO_2$ capture from large scale emission sources. To set up optimal operating parameters in $CO_2$ absorption and solvent regeneration units are important for the better performance of the whole $CO_2$ absorption plant. Optimal operating parameters are usually selected through a lot of actual operation data. However theoretical approach are also useful because the arbitrary change of process parameters often limited for the stability of process operation. In this paper, a theoretical approach based on vapor-liquid equilibrium was proposed to estimate optimal operating conditions of $CO_2$ absorption process. Two $CO_2$ absorption processes using 12 wt% aqueous $NH_3$ solution and 20 wt% aqueous MEA solution were investigated in this theoretical estimation of optimal operating conditions. The results showed that $CO_2$ loading of rich absorbent should be kept below 0.4 in case of 12 wt% aqueous $NH_3$ solution for $CO_2$ absorption but there was no limitation of $CO_2$ loading in case of 20 wt% aqueous MEA solution for $CO_2$ absorption. The optimal regeneration temperature was determined by theoretical approach based on $CO_2$ loadings of rich and lean absorbent, which determined to satisfy the amount of absorbed $CO_2$. The amount of heating medium at optimal regeneration temperature is also determined to meet the difference of $CO_2$ loading between rich and lean absorbent. It could be confirmed that the theoretical approach, which accurately estimate the optimal regeneration conditions of lab scale $CO_2$ absorption using 12 wt% aqueous $NH_3$ solution could estimate those of 20 wt% aqueous MEA solution and could be used for the design and operation of $CO_2$ absorption process using chemical absorbent.

Design and Implementation of Game Server using the Efficient Load Balancing Technology based on CPU Utilization (게임서버의 CPU 사용율 기반 효율적인 부하균등화 기술의 설계 및 구현)

  • Myung, Won-Shig;Han, Jun-Tak
    • Journal of Korea Game Society
    • /
    • v.4 no.4
    • /
    • pp.11-18
    • /
    • 2004
  • The on-line games in the past were played by only two persons exchanging data based on one-to-one connections, whereas recent ones (e.g. MMORPG: Massively Multi-player Online Role-playings Game) enable tens of thousands of people to be connected simultaneously. Specifically, Korea has established an excellent network infrastructure that can't be found anywhere in the world. Almost every household has a high-speed Internet access. What made this possible was, in part, high density of population that has accelerated the formation of good Internet infrastructure. However, this rapid increase in the use of on-line games may lead to surging traffics exceeding the limited Internet communication capacity so that the connection to the games is unstable or the server fails. expanding the servers though this measure is very costly could solve this problem. To deal with this problem, the present study proposes the load distribution technology that connects in the form of local clustering the game servers divided by their contents used in each on-line game reduces the loads of specific servers using the load balancer, and enhances performance of sewer for their efficient operation. In this paper, a cluster system is proposed where each Game server in the system has different contents service and loads are distributed efficiently using the game server resource information such as CPU utilization. Game sewers having different contents are mutually connected and managed with a network file system to maintain information consistency required to support resource information updates, deletions, and additions. Simulation studies show that our method performs better than other traditional methods. In terms of response time, our method shows shorter latency than RR (Round Robin) and LC (Least Connection) by about 12%, 10% respectively.

  • PDF

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF