• Title/Summary/Keyword: 실험적 상관식

Search Result 632, Processing Time 0.034 seconds

A Preliminary Experiment for Rayleigh-Benard Natural Convection for Severe Accident Condition (중대사고시 노심용융물의 Rayleigh-Benard 자연대류 예비 실험)

  • Moon, Je-Young;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.254-264
    • /
    • 2012
  • Rayleigh-Benard natural convection experiments were carried out as the preliminary experiment to simulate the natural convection of the core melt at the severe accident conditions. This work focused on the influences of plate separation distance(s), the existence of the side walls and crust geometries of upper and lower plates. Based upon the analogy concept, a cupric acid-copper sulfate electroplating system($H_2SO_4-CuSO_4$) was employed as the mass transfer system and measurements were made for $Ra_s$ ranging from $1.06{\times}10^7$ to $2.91{\times}10^{10}$. The test results measured for a single horizontal plate were in good agreement with the correlation reported by McAdams and those for two horizontal plates showed the similar trend to the existing Rayleigh-Benard heat transfer correlations developed by Dropkin and Somerscales, Globe and Dropkin. The measured heat transfer rate decreased with the increasing separation distance between the two plates and became similar to those for a single horizontal plate. Fin arrays mounted on both upper and lower plates enhanced the heat transfer rates. For all cases, the heat transfer rates measured for open side walls are higher than those for closed ones.

Cross Correlations between Probability Weighted Moments at Each Sites Using Monte Carlo Simulation (Monte Carlo 모의를 이용한 지점 간 확률가중모멘트의 교차상관관계)

  • Shin, Hong-Joon;Jung, Young-Hun;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.3
    • /
    • pp.227-234
    • /
    • 2009
  • In this study, cross correlations among sample data at each site are calculated to obtain the asymptotic cross correlations among probability weighted moments at each site using Monte Carlo simulation. As a result, the relations between the asymptotic cross correlations among probability weighted moments and the inter-site dependence among sample data at each site are nearly a linear relation with slope 1. The smaller ratio of concurrent data size to entire sample size is, the weaker the relationship grows. Simple power function which the correction term in power function accounts for the differences of the sample size between two sites was fitted to each case to estimate the parameter. It is noted that this result can be used in the various researches which include the estimation of the variance of quantile considering cross correlations.

Evaluation of Creep Models with the Consideration of Concrete's Strength Level (콘크리트 강도대별 크리프 예측모델 평가)

  • Moon, Jae-Heum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.154-159
    • /
    • 2010
  • Recent concrete structures have been being constructed with higher strength concrete than normal strength concrete. Therefore, it is necessary to review the applicabilities of current design codes and models for the prediction of mechanical behaviors of concrete materials such as creep. To investigate the applicability of creep model with the consideration of the strength level of concrete, three current models (ACI 209R, CEB-FIP MC90 and EC2) were studied and compared with series of experimental results. It was shown that EC2 model which is the updated model of CEB-FIP MC90 better predicts creep coefficient for high strength level concretes and showed relatively good agreements with experimental data.

The Condensation Heat Transfer of R-22 and R-410A in an Inner Diameter Tube of 1.77 mm (내경 1.77 mm관내 R-22와 R-410A의 응축열전달)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.48-53
    • /
    • 2008
  • The condensation heat transfer coefficients of R-22 and R-410A in a small diameter tube were investigated. The main components of the refrigerant loop consist of a receiver, a variable-speed pump, a mass flowmeter, an evaporator (preheater), and a condenser (test section). The test section consists of smooth, horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes varied from 450 to $1050\;kg/(m^2s)$ and the average inlet and outlet qualities were 0.05 and 0.95. The main results were summarized as follows : the condensation heat transfer coefficient also increases with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

  • PDF

Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel (수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달)

  • Riu, K.J.;Lee, J.H.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.29-41
    • /
    • 1999
  • Three-dimensional natural convective heat transfer in a vertical channel with a protruding single module was investigated experimentally. The particular interest was in the removal of thermal energy from the module by convective heat transfer. Hence radiative and conductive heat losses were estimated by using thermocouples and heat flux sensor respectively. The flow fields in the channel were visualized by means of a smoke-method. Also, local temperatures were measured by thermocouples inside the channel, along the vertical wall and module surface. It is found that convective heat transfer was promoted at the lower comer of the module and was decreased at the upper comer due to a recirculation zone. A general correlation of the critical channel ratios was found as a function of Rayleigh number. For the range of $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$, a useful correlation for the mean Nusselt number was proposed as a function of modified channel Rayleigh number.

  • PDF

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Verification of the Experimental Correlation for Dynamic Contact Angle by Visualizing Interfaces of Water-Glycerol Mixture Slug in a Hydrophobic Microtube via Synchrotron X-ray Imaging (방사광 X-선 영상법을 이용한 소수성 마이크로 관 내 물-글리세롤 혼합물 슬러그 계면 가시화를 통한 동적접촉각 상관식 검증)

  • Jang, Jin Gyu;Kim, Young Hyun;Kim, Kyoung Joon;Lee, Junghoon;Lee, Yeon Won;Yu, Dong In
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.145-150
    • /
    • 2022
  • Dynamic contact angles have investigated by numerous researchers for understanding interfacial behavior at moving contact lines However, due to limitation of visualization techniques, previous experiments for dynamic contact angles have conducted limitedly in hydrophilic capillary tubes based on visible ray. Recently, there is continuous need for research on dynamic contact angles in hydrophobic capillary tubes on various research and industrial fields. Therefore, in this study, we measure the dynamic contact angles of water-glycerol mixture slug in hydrophobic microtubes using synchrotron X-ray imaging. Based on the visualized data, we verified the previous experimental correlations for dynamic contact angles.

3X3 봉다발에서의 국소 열전달에 관한 실험적 연구

  • 정장환;정문기;유성연
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.356-361
    • /
    • 1996
  • 물질전달과 열전달의 유사성을 이용하는 나프탈렌 승화법을 핵연료집합체 모델에 적용하여 봉다발에서의 국소 열전달 계수의 분포를 측정하였다. 실험 모델은 가압경수형 원자로에서 나타나는 부수로 즉, 벽면 부수로와 모서리 부수로 및 내부 부수로로 구성되는 3$\times$3 봉다발이다. 봉다발에서의 국소 열전달 계수 값은 부수로의 형상과 인접한 봉 및 벽면의 영향이 크게 작용하는 것으로 측정되었다. 내부 부수로에 둘러져 있는 봉에서의 국소 열전달계수값은 봉과 봉 사이에서는 부수로 중심 방향보다 낮았고, 평균열전달계수는 Dittus-Boelter의 상관식보다 약간 낮은 값을 보였다. 벽면 부수로에 인접한 봉에서의 열전달계수는 벽면의 영향으로 내부 부수로에 있는 봉보다 상대적으로 낮았으며, 모서리 부수로의 봉에서는 벽면의 영향이 증대되어 더욱 낮게 나타났다.

  • PDF

Instrumental and Sensory Characteristics of Jelly (젤리의 기계적 및 관능적 물성)

  • Lee, Tae-Whi;Lee, Yoon-Hyung;Yoo, Myung-Shik;Rhee, Kyu-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.336-340
    • /
    • 1991
  • Correlations among instrumental. sensory parameters and overall preference of jelly texture were studied. Instrumental rheological characteristics of the jelly were measured with a rheometer, and sensory and overall score were measured by sensory evaluation. Instrumental maximum force was correlated to sensory hardness and shortness, and sensory springiness and stickiness were correlated to instrumental springiness and adhesiveness force respectively. Also the most significant instrumental parameters with respect to overall preference were cohesiveness and adhesiveness force with their values being 0.93 and 0.89 repectively. Multiple linear regression resulted in a following equation: overall score = 2.70 + 6.25(cohesiveness) - 0.095(adhesiveness force) with a correlation coefficient of 0.94.

  • PDF

An Edge Directed Color Demosaicing Algorithm Considering Color Channel Correlation (컬러 채널 상관관계를 고려한 에지 방향성 컬러 디모자이킹 알고리즘)

  • Yoo, Du Sic;Lee, Min Seok;Kang, Moon Gi
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.619-630
    • /
    • 2013
  • In this paper, we propose an edge directed color demosaicing algorithm considering color channel correlation. The proposed method consists of local region classification step and edge directional interpolation step. In the first step, each region of a given Bayer image is classified as normal edge, pattern edge, and flat regions by using intra channel and inter channel gradients. Especially, two criteria and verification process for the normal edge and pattern edge classification are used to reduce edge direction estimation error, respectively. In the second step, edge directional interpolation process is performed according to characteristics of the classified regions. For horizontal and vertical directional interpolations, missing color components are obtained from interpolation equations based on intra channel and inter channel correlations in order to improve the performance of the directional interpolations. The simulation results show that the proposed algorithm outperforms conventional approaches in both objective and subjective terms.