• Title/Summary/Keyword: 실제 기체

Search Result 232, Processing Time 0.026 seconds

LN2 storage test and damage analysis for a Type 3 cryogenic propellant tank (타입 3 극저온 추진제 탱크의 액체질소저장 시험 및 파손 분석)

  • Kang, Sang-Guk;Kim, Myung-Gon;Park, Sang-Wuk;Kong, Cheol-Won;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.7
    • /
    • pp.592-600
    • /
    • 2007
  • Nowadays, researches for replacing material systems for cryotanks by composites have been being performed for the purpose of lightweight launch vehicle. In this paper, a type 3 propellant tank, which is composed of the composite developed for cryogenic use and an aluminum liner, was fabricated and tested considering actual operating environment, that is, cryogenic temperature and pressure. For this aim, liquid nitrogen (LN2) was injected into the fabricated tank and in turn, gaseous nitrogen (GN2) was used for pressurization. During this test procedure, strains and temperatures on the tank surface were measured. The delamination between hoop layer and helical one, was detected during the experiment. Several attempts were followed to investigate the cause analytically and experimentally. Thermo-elastic analysis in consideration of the progressive failure was done to evaluate the failure index. Experimental approach through a LN2 immersion test of composite/aluminum ring specimens suitable for simulating the Type 3 tank structure.

A Study on the Flow Control for Stable Combustion of Liquid Rocket (액체로켓의 연소안정을 위한 유량공급에 관한 실험적 연구)

  • Jang, Eun-Young;Park, Hee-Ho;Kim, Sun-Ki;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.2
    • /
    • pp.6-11
    • /
    • 2000
  • In the pressurized propellant feed system of liquid rocket, feed pressure is decided chamber pressure of normal combustion state. However, during ignition period the initial chamber pressure is atmosphere. So, it may have overflow, hard-start and even critical damage of engine. This paper proposes an improved propellant feed system for the stable combustion of liquid rocket. Hot test were already performed to verify the presented propellent feed system. The proposed propellant feed system uses two steps - pre and main combustion - to prevent large pressure increase and uses cavitating venturis for stable flow rate in whole combustion. This system feeds the flow rate lesser than the designed flow rate, so combustion pressure reached pre-combustion pressure. Cavitating venturis offer unique flow control capabilities at normal and abnormal combustion state, because flow rate is solely dependent on upstream absolute pressure and fluid properties, but independent on downstream condition.

  • PDF

Modified Agglomerated Film Model Applied to a Molten Carbonate Fuel Cell Cathode (실측자료를 이용한 Agglomerated Film Model의 용융탄산염 연료전지 산소전극 성능모사)

  • 임준혁;김태근
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.593-603
    • /
    • 1996
  • A dual-porosity filmed agglomerate model for the porous cathode of the molten carbonate fuel has been investigated to predict the cell performance. A phenomenological treatment of molecular, kinetic and electrode parameters has been given. The major physical and chemical phenomena being modeled include mass transfer, ohmic losses and reaction kinetics at the electrode- electrolyte interface. The model predicts steady-state cell performance, given the above conditions that characterize the state of the electrode. Quasi-linearization and finite difference techniques are used to solve the coupled nonlinear differential equations. Also, the effective surface area of electrode pore was obtained by mercury porosimeter. The results of the investigation are presented in the form of plots of overpotential vs. current density with varied the electrode material, gas composition and mechanism. The predicted polarization curves are compared with the empirical data from 1 c$m^2$ cell. A fair correspondence is observed.

  • PDF

Development and Application of an Ultrasonic Gas Flowmeter (초음파 가스 유량계 개발과 활용)

  • Hwang, Won-Ho;Park, Sang-Gug;Jeong, Hee-Don;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.246-253
    • /
    • 2002
  • This paper describes the development and the field application of the ultrasonic gas flowmeter for accurate measurement of the volumetric flow rate of gases in a harsh environmental conditions in iron & steel making company. This ultrasonic flowmeter is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. This is a transit time type ultrasonic flowmeter. We have developed the transmitting & receiving algorithm of ultrasonic wave and the ultrasonic signal processing algorithm to develope a transit time type ultrasonic flowmeter. We have evaluated the performance of ultrasonic flowmeter by the calibration system with Venturi type standard flowmeter. We has confirmed its reliability by extensive field tests for a year in POSCO, iron & steel making company. Now we have developed the commercial model of ultrasonic flowmeter and applied to the POSCO gas line.

Studies on Adsorption and Desorption of Ammonia Using Covalent Organic Framework COF-10 (Covalent Organic Framework (COF-10)를 이용한 암모니아 흡착 및 탈착에 관한 연구)

  • Yang, Heena;Kim, Iktae;Ko, Youngdon;Kim, Shindong;Kim, Whajung
    • Applied Chemistry for Engineering
    • /
    • v.27 no.3
    • /
    • pp.265-269
    • /
    • 2016
  • Ammonia gas as a hydrogen source has received great attention since the importance of hydrogen gas as a clean energy source increased. However, ammonia is toxic and corrosive to metal such that the absorbent that can store and transport ammonia became an important issue. As an effort to solve this, a large pored covalent organic framework, COF-10 was proposed as an adsorbent for storage and safe transportation of ammonia. During the ammonia adsorption process, boron in COF-10 structure can act as a Lewis acid site and bind with ammonia. In this study, COF was synthesized and its structure was identified by BET, XRD and FT-IR. The adsorption characteristics of COF were investigated by TPD and adsorption isotherm. The COF-10 showed an excellent adsorption capacity for ammonia (9.79 mmol/g) which could be utilized as an ammonia adsorbent.

A Study on the Hypochlorination Reaction for Improvement of Epichlorohlydrin Production Process : Reduction of Side Reacion (ECH 생산공정 개선을 위한 Hypochlorination 반응에 관한 연구 : 부반응 억제)

  • Lee, Chul Haeng;Jeon, Sang Jun;Lee, Tai-yong;Wong, Won Hi;Yun, Chang Han;Kim, Young Sub;Cho, Byong Nam;Kim, Yeon Seok
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2003
  • The methods for improving epichlorohydrin process was investigated by carrying out experiments on hypochlorination reaction, from which dichlorohydrin is produced by reacting with allyl chloride and chlorine. As the recycle water from PVC plant was used instead of industrial water for reaction, the effect of recycle water on the reaction yield was studied. It was shown from this experiment that the recycle water rarely affected on the ratio between products. TCPA, which was almost of byproducts, could be removed before purification process using "extractant A". This could prevent additional side reaction by TCPA and reduced energy to separate it in purification part. The change of product yield was observed as the chlorine gas addition decreases which reacted with allyl chloride. It seems that the yield of major products didn't change almost, but the byproducts showed rather reduced trend with decreasing chlorine gas.

  • PDF

Adsorption characteristics of the sericite and diatomite for ammonia gas (견운모와 규조토에 대한 암모니아 기체의 흡착특성)

  • Lee, Suseung;Kim, Jinsoo;Yun, Chang Yeon;Yi, Jongheop
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.175-181
    • /
    • 2006
  • The feasibility of the use of porous fossil diatoms for indoor air pollution control was investigated via the characterization of physical and chemical properties. The fossil diatoms were observed by SEM(Scanning Electron Microscope). Diatomite had well-distributed pores below 5 nm and relatively large surface area compare to sericite. However, no porosity in sericite was found. Results showed that diatomite had better performance than sericite in respect to porosity and large surface area. But diatomite which is thermally treated at $950^{\circ}C$ has no porosity and low surface area because of combustion of fossil diatoms or calcination of inorganic oxide at high temperature, and has poor adsorption capability of ammonia gas. In conclusion, porous diatomite has relatively high performance to adsorb noxious chemical compounds, such as ammonia gas and VOCs.

  • PDF

Evaluation of Sampling and Analytical Methods for the Determination of Polycyclic Aromatic Hydrocarbons in the Ambient Atmosphere (환경대기중 다환방향족탄화수소의 포집과 분석방법에 관한 연구)

  • 백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.1-16
    • /
    • 1991
  • In this study, sampling and analytical procedures were evaluated for the determination of ambient levels of atmospheric PAH, both in gaseous and particulate phase. The method involves low-volume sampling and Soxhlet extraction of the filters and Tenax absorbent, followed by a clean-up stage using a silica column prior to analysis by reversed-phase HPLC with wavelength programmable fluorescence and UV detection. A total of 18 PAH were identified and quantified, all of which have been of environmental concern. In order to validate the methodology and to ensure compatibility of the results, the analytical method used for the determination of PAH was evaluated with respect to the efficiencies of extraction and clean-up procedure, HPLC separation, and lower limits of detection. In addition, substrate dependency of PAH recovery was investigated for the two types of fiters, i.e. glass fiber and PTFE filters.

  • PDF

Determination of Sulfur Compounds in Gaseous Fuel by Gas Chromatography-Sulfur Chemiluminescence Detection (GC-SCD를 이용한 가스연료 중 황화합물의 정량)

  • Do, Lee Joo;Koh, Jae Suk;Kim, Ho Jin
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.5
    • /
    • pp.517-521
    • /
    • 1999
  • Gas chromatography using sulfur chemiluminescence detection (GC-SCD) which exhibits very good selectivity, linearity, and sensitivity was applied to the analysis of suIfur compounds in gaseous fuel. The expectmental method used in this study was to resolve the problems of repeatability and reproducibility by means of the adsorption of sulfur compounds, which is different from the existing analysis method of these compounds by GC-SCD. The calibration curves of the standard gases including dimethyl sulfide, t-butylmercaptan and ethyl methyl sulfide exhibited an excellent linearity. As the result of precision tests for the above three compounds, the high reproducibility for tests showed while repeating three times during four days, respectively. In addition, the coefficient of variation was less than 3%. In consequence, the expectmental method of this study is very effective not only with low uncertainty but also with better accuracy, which can quickly determine the concentration of gas odorants in LPG (Liquefied Petroleum Gas) from oil reservoirs and filling stations.

  • PDF

New calibration apparatus for a precise barometer (초정밀 기압계 교정을 위한 새로운 압력계 교정장치 개발)

  • 우삼용;이용재;최인묵;김부식;최종운
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.157-161
    • /
    • 2003
  • Nowadays there are increasing demands for more accurate measurement of atmospheric pressure according to the development of environmental industries. One of the most important pressure gauges for satisfying these demands is a quartz resonance barometer. In order to calibrate such an accurate barometer, laser/ultrasonic mercury manometers have been used. However, complexity and cost of mercury manometers made it out of use gradually. As a substitute, a gas-operated pressure balance is used for calibration of precise barometers. In such a case, commercially available pressure balances cannot be entirely suitable because consequent exposure of the piston, cylinder and masses to the atmosphere causes the problem of contamination. In this paper a device for changing the masses in situ without breaking the vacuum is described. This device made it possible to add or remove weights in the absolute mode, thereby greatly reducing the time between observations. At the same time, we investigated the characteristics of a commercial precise barometer using this new apparatus.