• Title/Summary/Keyword: 실제 굴절검사

Search Result 14, Processing Time 0.024 seconds

An Evaluation of the Virtual Refraction Education (가상 굴절검사 교육에 대한 평가)

  • Yu, Dong-Sik;Son, Jeong-Sik;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.43-50
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effect of a VR (Virtual Refractor), which is a simulator for a PR (Practical Refraction), as an educational tool. Methods: Twenty four third year students enrolled in the department of visual optics volunteered for VR education. Each student attended a VR training course and practiced with the VR by themselves. One month later, each student tested three virtual subjects on the VR and one real subject on the PR and were given a performance score for each refraction. And the scores for the virtual and practical refractions were compared. In addition, a self-report questionnaire based on a five point Likert-scale was designed, consisting of domains such as spontaneous participation, contribution for the refraction, confirmity of the VR and PR, and necessity of the VR. Results: The Spearman's correlation coefficient between the testing score of the practical and virtual refractions indicated a significantly correlation (R=0.71, p<0.001). In the questionnaire, the mean score of the domains was 3.67${\pm}$0.96 and it indicated that students expressed that using the VR was beneficial. The correlation value among these domains was a high significant level, 0.91~0.68 (p<0.001). Conclusions: Although the VR required certain improvements in its concentration and systematic approaches for practical situations, it showed a high correlation between the VR and the PR and represented a positive evaluation in the PR.

  • PDF

Refraction angle of the transverse wave near the longitudinal critical angle in angle beam transducer (종파 임계각 근처에서 사각 탐촉자의 횡파굴절각)

  • Lee Jeong-Ki;Lim Seong-Jin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.303-306
    • /
    • 2000
  • 복잡한 형상을 지닌 터빈 블래이드의 결함을 검사하기 위해 현재 $35^\circ,\; 38^\circ,\; 40^\circ$의 횡파 굴절각을 지닌 탐촉자를 사용하고 있다. 이와 같은 굴절각은 초음파 빔의 경로를 Snell의 법칙에 의해 설정하고 있다. 그러나 터빈 블래이드 검사용 초음파 탐촉자를 제작하는 과정에서 $35^\circ$의 횡파 굴절각을 갖는 경사각 탐촉자는 제작이 어려움을 알았다. 이러한 원인은 철강재료의 종파임계각이 $33.2^\circ$의 횡과굴절각에 대응되며, 종파임계각 근처에서는 전반사 현상 때문에 에너지 투과율이 매우 작아 실제 시험대상체에 입사되는 에너지가 거의 없으며 또한 횡파굴절각이 약 $37.5^\circ$ 일때에 휭파의 에너지 투과율이 최대가 되어 wedge를 $37.5^\circ$ 이하의 횡파굴절각을 갖도록 설계하더라도 측정을 하면 $37.5^\circ$ 근처의 횡파굴 절각을 갖게된다. 즉, 종파임계각 근처에서는 전반사 현상에 의해 경계면에서의 에너지 투과가 매우 작아 횡파 굴절각은 Snell의 법칙이 아닌 초음파 에너지의 투과 정도를 나타내는 echo transmittance의 크기에 의해 결정된다.

  • PDF

Phenomenological Model for Vibration Control of Booms on Articulated Bridge Inspection Robots (교량검사 굴절로봇 붐의 진동제어를 위한 수치모델에 관한 연구)

  • Shin, Ki-Bum;Lee, Hu-Seok;Hwang, In-Ho;Lee, Jong-Seh
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.536-539
    • /
    • 2009
  • BIRDI(Bridge Inspection Robot Development Interface)에서 현재 개발된 첨단굴절로봇차는 비전 시스템과 로봇 플랫폼을 붐에 장착하여 교량 하부를 점검하는 점검용차량이다. 본 연구에서는 첨단굴절로봇차의 포스트 붐에 엑츄에이터를 장착하여 강풍 등으로 발생이 예상되는 유해 진동을 제어할 수 있는 시스템을 제안하였으며, 성능 평가를 위해 수치적 연구를 수행하였다. 제안된 제어시스템의 수치적 연구를 위해 현재 제작된 포스트 붐과 작업 붐의 제원을 이용하여 모델링 하였으며, 적절한 주파수 특성을 가진 하중을 가정하였으며, 최적 제어이론인 PD제어기법인 피드백 제어기법을 적용하여 수치해석을 수행 하였다. 수치해석 결과, 제안된 제어시스템은 L형 붐에 발생되는 유해 진동을 저감시킴을 확인하였다. 본 연구를 통해 제안된 시스템의 진동제어 성능을 입증하였으며, 실제 첨단굴절로봇차에 적용될 경우 점검 시스템의 성능을 향상시킬 수 있을 것으로 사료된다.

  • PDF

The Necessity and Requirement of Trial Lens Set Standardization (검안렌즈 표준화의 필요성과 규격에 관한 연구)

  • Park, Sang-Yeul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.217-223
    • /
    • 2006
  • The purpose of this study is to provide improvements and standards of trial lens, in a situation that there is a lack of standards of trial lens set that have been used for self-conscious refraction test after helm refraction test at about 5,000 opticians, ophthalmologic clinics and hospitals, and contact-lens shops, that there is a lot of discrepancies between refraction specified and the actual power, and that there is no regulation of optical tolerance error. For the study, opticians who have used Trial lens set were asked to participate in a questionnaire survey through continuing education, and divided into those who have used domestic lens and those who have used imported lens, 5 opticians each for less than 5 years, 5 to 10 years, more than 10 years. The measurement of both refraction specified and the actual diopter was compared to Japan Industrial Standards(JIS T4402). As a result of comparative analysis, more than 80% of respondents have had reliability on the refraction of trial lens they had used, indicating that they have never measured the refraction specified and the actual diopter after buying them. Besides, Korean Industrial Standards(KS P4402) has been imperfect in diopter range since it was legislated in 1979. More than 95% of respondents have been unsatisfied with optometry. Also, it has indicated that refraction error is more frequent in long-term-used trial lens. The conclusion is that it is necessary to standardize trial lens set and that it is required to add lens to lens set provided under KS P4402. Moreover, it is necessary to have supervisory agency for a standardization of trial lens. I hope that both domestic lens and imported lens, as in German and Japan, will be tested to find whether they meet optical tolerance error and standard trial lens will be distributed. Good optic inspection is required for the improvement and management of eye health and optical function, and the same standard trial lens set should be used. whoever is tested. Also, I hope that trial lens set will be specified within standards and tolerance error.

  • PDF

Development and Application of Peer Instruction Materials for In-service Teachers' Training through Ray Drawing: Focus on Refraction of Light (광선작도 활동을 포함한 동료교수법 교사연수 프로그램의 개발 및 적용 : 빛의 굴절 개념을 중심으로)

  • Lee, Ji Won;Kim, Da Young;Kim, Jung Bog
    • Journal of Science Education
    • /
    • v.38 no.1
    • /
    • pp.182-195
    • /
    • 2014
  • Ray drawing in geometrical optics is an effective method for visible imagery of light. In this study, we developed peer instruction materials for in-service teachers' training concepts on the refraction of light including drawing rays. And then we applied these programs to 29 pre-service teachers and 21 in-service primary teachers and evaluated the degree of conceptual change in correct points from the pretest and the post one. As a result of pretesting, in spite of experiences for learning this topic in elementary and secondary education courses, most participants in the study did not well understand the path of refracted light before instructions. However, the result of post testing after the application of peer instruction materials shows that they have practiced ray drawing, which is helping visible imagery. Accordingly, in learning geometrical optics, we suggest that peer instruction with ray drawing activity for teachers' training program would be effective. We also suggest that similar approaches would be applied to other context.

  • PDF

Vibration Control of Working Booms on Articulated Bridge Inspection Robots (교량검사 굴절로봇 작업붐의 진동제어)

  • Hwang, In-Ho;Lee, Hu-Seok;Lee, Jong-Seh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.421-427
    • /
    • 2008
  • A robot crane truck is developed by the Bridge Inspection Robot Development Interface(BRIDI) for an automated and/or teleoperated bridge inspection. This crane truck looks similar to the conventional bucket crane, but is much smaller in size and light-weight. At the end of the telescoping boom which is 12m long, a robot platform is mounted which allows the operator to scan the bridge structure under the deck trough the camera. Boom vibration induced by wind and deck movement can cause serious problems in this scanning system. This paper presents a control system to mitigate such vibration of the robot boom. In the proposed control system, an actuator is installed at the end of the working boom. This control system is studied using a mathematical model analysis with LQ control algorithm and a scaled model test in the laboratory. The study indicates that the proposed system is efficient for the vibration control of the robot booms, thereby demonstrating its immediate applicability in the field.

An Electronic System in Automatic Refracto-Keratometer (자동 시각 굴절력 곡률계의 전자 부문 시스템)

  • Seong, Won;Ryu, Gang-Min;Park, Jong-Won
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.6
    • /
    • pp.669-678
    • /
    • 2002
  • Currently, the domestic interests on the development of eyesight related measuring instruments are being increased. So we are developing such an electronic system of Refracto-keratometer, which contains a software and a hardware both. If this system could inform the examiner of the precise eyesight measuring result from the treatment of the image of optical system, then potentially the number of missed measuring results could be reduced. Our electronic system has been developed from the two areas divided into a software and a hardware. The software area was focused on the more exact eyesight measuring results, using morphological filtering methods and gray-leveled signal enhancing techniques. The hardware area is performing the same functions as the existing other systems. Besides, it provides the embedded software with free variables which could reduce the developing duration sharply as well as enlarge many kinds of application-extensions. Therefore, this electronic system has made effective eyesight measurement possible as the result of reducing the differences applied to sophisticated eyesight measurement.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.

Accommodative response measurement using both eyes open-view autorefractometer (양안 개방형 자동굴절검사기를 이용한 조절반응량 검사)

  • Shim, Hyun-Seog;Lee, Seong-Wook;Shim, Moon-Sik;Choi, Sun-Mi;Jang, Seong-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of this research was to measurement real Accommodative response amount using both eyes open-view autorefractometer. Compared each Accommodative response amount to distinction of sex, age, kind of ametropia, amount of astigmatism and kind of astigmatism. The subjects were 153 healthy men and women between the age of 20~80 years. Age comparison, 20 years 1.15D, 30 years 1.23D and above 40 years 0.60D. It was no difference between 20 to 30 years old. But, is decrescent remarkably above 40 years old. Ametropia examined by hypermetropia 1.78D, emmetropia 1.51D, low myopia 1.08D, middle myopia 0.72D, high myopia 0.643D. Myopia increased, Accommodative response amount was expose that decrease. Astigmatism examined by non astigmatism 1.13D, low astigmatism 1.12D, middle astigmatism 0.85D, high astigmatism 0.83D. Astigmatism increased, Accommodative response amount was expose that decrease. The sex and astigmatism type difference appeared with the fact that the result is not a difference.

  • PDF

Study on Mounting Status of Trial Case Lenses (검안렌즈의 장착상태에 대한 연구)

  • Cho, Hyun-Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.405-411
    • /
    • 2013
  • Purpose: In this study, the mounting status of trial case lens was investigated. Methods: We measured distances between geometric center of lens mount and optical center of lens and angle deviations between axis mark on lens and real axis using arbitrary trial case lens sets distributed in Korea, and then, compared those results with international standards. Results: In some of lenses, the prismatic power on geometric center of lens mount and the angle deviations between axis mark and real axis of cylindrical lens were out of tolerance according international standards. Conclusions: The more precise control of the manufacturing process and more thorough quality control for trial case lenses will be required to offer an accurate vision test.