Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (에어컨 실외기의 소음원 규명 및 소음저감)

  • 서상호;임금식;이내영;진심원
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1043-1052
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan. heat exchanger and shroud. First. the fluid noise is reduced through the design of new fan and shroud. reduction of the system resistance by rearrangement of heat exchanger. and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4∼5dB (A).

  • PDF

A research on the actual conditions of the electric shock hazard of a electrical facilities on the road (현장조사를 통한 도로시설물의 감전위험성)

  • Jang, Tae-Jun;Jung, Yeon-Ha;Roh, Young-Su;Kwak, Hee-Ro;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.359-363
    • /
    • 2005
  • 본 논문에서는 도로시설물의 감전 위험성의 실태를 파악하기 위하여 신호등, 공중전화, 입간판, 에어콘 실외기를 현장 조사하였다. 취득된 자료에 의거하여 도로시설물의 실태를 감전 위험성 측면에서 정밀하게 분석하였다. 조사결과, 규정이 미비하여 많은 시설물들이 올바르게 설치되어 있지 않기 때문에 감전의 위험성이 있는 것으로 밝혀졌다. 따라서 감전 예방의 관점에서 도로시설물의 설치 및 관리에 대한 구체적인 규정을 설정하는 것이 필요하다.

  • PDF

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (실외기 소음원 규명 및 소음저감)

  • 서상호;이근동;이내영;진심원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.575-581
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC(Room Air Conditioner) are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan, heat exchanger and shroud. First, the fluid noise is reduced through the design ol new fan and shroud with high flow rate and low noise, reduction of the system resistance by rearrangement of heat exchanger, and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4-5dB(A).

  • PDF

The performance evaluation of outdoor unit cooling system in a residential apartment complex (주상복합의 실외기 형태에 따른 냉방시스템 성능 평가)

  • Kyung, Seo-Kyung;Kim, Yun-Jin;Lim, Jung-Hee;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

Environmental Noise Assessment of Outdoor Air-conditioner Fans by Using Ray Tracing Method (레이추적법에 의한 에어컨 실외기의 환경소음 예측에 관한 연구)

  • Choi, Jin-Kwen;Chang, Seo-Il;Lee, Jin-Kyo;Lee, Soo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1444-1449
    • /
    • 2000
  • This environmental influence of the noise produced by a number of air-conditioner out-door units in a multi-unit housing is predicted and evaluated. The method based on Ray tracing theory and mirror image source theory is utilized. Each ventilation window in a machine room is considered as a sound source which contributes to the overall noise level of the surrounding environment. The adopted method has been found a very efficient tool to assess the environmental noise impact.

  • PDF

The prediction of sound transmission from air-conditioner outdoor-units in multi-unit housings (공동주택 에어컨 실외기의 투과소음 예측 및 저감방안에 관한 연구)

  • Choi, Jin-Kwen;Chang, Seo-Il;Lee, Jin-Kyo;Kang, Jeong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.996-1001
    • /
    • 2000
  • The sound transmission from the machine room where air-conditioner outdoor unit is located into the adjacent room is predicted and evaluated. The software package for statistical energy analysis(SEA) is utilized to determine the transmission losses of multi-layerd panels. To determine the noise level in the machine room, ray tracing method is adopted. The various sound transmission paths have been effectively identified and evaluated by the SEA tool.

  • PDF

Research on initial current control scheme for PWM converter (PWM 컨버터 인버터 시스템의 컨버터부 초기 전류 제어 기법에 대한 연구)

  • Gu, Bon-Gwan;Choi, Jun-Hyuk;Jung, In-Soung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.946-947
    • /
    • 2008
  • 시스템 에어컨은 가정이나 사무실에서 하나의 실외기를 사용하면서, 각 방 또는 사무실에 여러 대의 실내기를 사용하는 에어컨 방식이다. 시스템 에어컨은 가정이나 사무실에 사용하는 가장 큰 에너지 부하 중 하나 로서 점차 그 사용이 증대되고 있다. 본 논문에서는 이 시스템 에어컨에 사용되는 컨버터 인버터 시스템의 컨버터 초기 운전 방법을 제안한다. 본 방법은 컨버터 운전 초기에 발생할 수 있는 제어 전압 부족으로 인해 발생할 수 있는 과전류를 미리 방지하여 컨버터 보호 및 비정상적 운전을 방지할 수 있는 방법이다.

  • PDF

Environmental Noise Assessment of Indoor and Outdoor Units of Air-conditioner (에어컨 실내기의 방사소음과 실외기의 투과소음에 의한 환경소음 예측)

  • 장서일;최진권;손진희;모진용;구형모
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.40-47
    • /
    • 2003
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were efficiently reflected on the simulated results. So it is important that measuring the acoustic parameter prior to the prediction of the transmitted sound level in the house.

Flow Noise in the Outdoor Unit of an Air-conditioner (에어컨 실외기에서의 유동소음)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

Sensorless Control Algorithm of a PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han Sol;Cho, Kwan Yuhl;Kim, Hag Wone;Cha, Youn Cheul
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.72-73
    • /
    • 2017
  • 자동차 라디에이터용 팬과 에어컨 실외기 팬의 경우 영구자석동기 전동기는 자연 상태에서 외부 바람에 의해 임의의 방향과 임의의 속도로 회전할 수 있다. 이런 응용분야에서 회전자 위치검출 센서가 부착되어 있는 경우에는 회전방향 및 속도를 비교적 간단하게 제어할 수 있다. 그러나 회전자 위치검출 센서를 사용하지 않는 센서리스 제어의 경우 외부부하에 의해 회전자가 회전중일 때는 회전자의 위치정보가 없기 때문에 추가적인 알고리즘이 필요하다. 본 논문에서는 외부부하에 의해 회전자가 임의의 방향 및 임의의 속도로 회전하고 있는 경우 원하는 회전방향으로 원하는 속도로 제어하기 위한 센서리스 제어 알고리즘을 제안한다. 회전자가 역방향 및 정방향 저속으로 회전중인 경우와 정방향 고속으로 회전중인 경우에 대해 회전자를 정방향의 주어진 속도로 제어하기 위한 회전자 위치검출 및 센서리스 제어 알고리즘을 제안하고 실험으로 검증한다.

  • PDF