• Title/Summary/Keyword: 실물 시험

Search Result 303, Processing Time 0.032 seconds

Test research of Structural Safety for Steel Wire-Integrated Deck Plate System (철선일체형 데크 플레이트 구조성능평가를 위한 실험적 연구)

  • Lee, Yong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.220-228
    • /
    • 2010
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of a slab or formwork such as shores and supports, and it is already widely applied in many construction fields. This study selected upper and lower steel wires, lattice steel wires, span, and cutting methods of ends as variables, and conducted an experimental test by manufacturing a total of 32 full scale test bodies. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test bodies, and for a 3.2m-span test body, there was no big problems in using ${\Phi}4.5$ of lattice steel wires.

Development of 30-Tonf LOx/Kerosene Rocket Engine Combustion Devices(II) - Gas Generator (추력 30톤급 액체산소/케로신 로켓엔진 연소장치 개발(II)-가스발생기)

  • Choi, Hwan-Seok;Seo, Seong-Hyeon;Kim, Young-Mog;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1038-1047
    • /
    • 2009
  • The development process of a gas generator for a 30-tonf pump-fed space liquid rocket engine is described. Starting from the development of an injector, followed by subscale and full-scale test specimens, the development of LOx/kerosene fuel-rich gas generator has been concluded successfully. Various analytical methods have been utilized in the course of design and the performance requirements have been verified experimentally through ignition tests, combustion performance and stability assessment tests and duration tests. The gas generator has proven its workability and stability within a defined operation window of varying chamber pressure and mixture ratio and demonstrated compliance to the performance and life time requirements.

Development of Steel Wire-Integrated Deck Plate Applicable to Slab with 180mm Thickness (두께 180mm 슬래브에 적용 가능한 철선일체형 데크 플레이트 개발)

  • Lee, Yong Jae;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.89-98
    • /
    • 2012
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of slabs or formworks such as shores and supports, and it is already widely applied in many construction fields. In this research, experimental tests for 14 full scale specimens, which are in the same field conditions, are conducted on several parameters such as the diameter of top, bottom and lattice steel wire, cutting methods of ends. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test specimens, and for a 4.0m-span test specimen, there was no big problems in using bottom bar D7 or D8.

Development of an Empirical Equation for Estimating Lond Transfer Curve for Micropile in Weathered Soils (풍화지반에 근입된 마이크로파일의 하중전이곡선 추정을 위한 경험식 개발)

  • Park, Seong-Wan;Cho, Kook-Hwan;Roh, Kang-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2007
  • Micropiles have been used for underpinning or rehabilitation of existing foundations, and direct structural support system as well. However, relatively few studies have been done on the load-transfer mechanism of micropile systems in Korea. In addition to that, only the limited information is available for estimating the side friction values on micropiles installed in weathered soils. In this study, a full-scale test on an instrumented micropile is performed in order to establish the load-transfer curves based on a hyperbolic function. Then, an empirically derived equation that correlates the load-transfer curve of micropiles with the N values from field standard penetration tests is proposed. The results from all procedures are presented in this paper. Finally, back analysis using a finite difference method and the published field data are adopted for examination of a developed skin friction equation of micropile in weathered soils respectively.

조적공사시 개구부상단 인방보용 강재구조물에 관한 실험적 연구

  • Kim, Yeong-Chun;Jeong, Hyeon-Ok;Song, Chang-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.159-166
    • /
    • 2012
  • 본 연구는 조적공사 중 반매(0.5B)쌓기 시멘트벽돌 시공시 개구부 상부에 시공되는 중량의 인방보용 콘크리트 구조물 대신 경량의 강재구조물을 안전하게 사용할 수 있도록 강재구조물이 개구부 상부 시멘트벽돌 하중을 견딜 수 있는지 실험을 통해 검증해 보기위한 것이다. 강재구조물이 시멘트벽돌을 쌓는데 방해가 되지 않도록 강재구조물 형상을 제안하였고 휨실험을 실시하여 구조형상을 검증하였다. 실험결과를 바탕으로 강재구조물에 치올림(camber)을 두어 시멘트벽돌 반매(0.5B)쌓기 실물 재하시험을 실시한 결과 시공성이 개선되고 공사 중 안전사고 방지에도 효과가 있는 것으로 확인되었다.

  • PDF

Measured Performance of Full Scale Tieback Walls in

  • Kim, Nak
    • Geotechnical Engineering
    • /
    • v.14 no.3
    • /
    • pp.5-24
    • /
    • 1998
  • Two instrumented full scale tieback walls in sand were constructed at to Geotechnical Experimentation Site located on the Texas A 51M University Riversic Measurements were obtained from the one row anchor wall and from the two row at different times during construction. The measured performance of the tieback walls is presented and investigated. The these walls at different construction stage is evaluated with respect to lateral wall. settlement of the ground, bending moment of the wall. axial load distribution and anchor load variation. The fundamental mechanism of a tieback wall in sand is and explained with the measurements.

  • PDF

Resonant Fatigue Testing of Full-Scale Composite Helicopter Blades (공진현상을 이용한 실물 복합재 헬리콥터 블레이드의 피로수명 평가)

  • Kee, Young-Jung;Kim, Tae-Joo;Kim, Seung-Ho
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • Fatigue properties of composite materials are extremely important to design durable and reliable helicopter rotor blades. However, it is very difficult to apply conventional fatigue test loads in short period. Therefore, accelerating test speed and facilitating spectrum load realization are required. In this study, we have developed a fatigue testing method that uses a resonance of simply supported beam type blade specimen. This test consists in exciting the blade specimen with a frequency that corresponds to its natural frequency. In that case, the test specimen similar to a beam fixed between two pivot points starts vibrating and is significantly deformed. Resonant fatigue tests were performed by changing exciting vertical amplitude and frequency, and S-N curves of each composite materials were successfully obtained.

Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members (격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가)

  • Noh, Myung-Hyun;Ahn, Dong-Wook;Joo, Hyung-Joong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.

A Study on the Injury Criteria of the Occupant Protection Performance of Crush Cushions (충격흡수시설의 탑승자보호 성능평가 기준에 관한 연구)

  • Lim, Jae-Moon;Jung, Geun-Seup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • The performance of crash cushion systems is certified through the full scale crash tests by the standard for installation and maintenance guidelines for roadside safety appurtenance. The impact severities of impacting vehicles in collision with crash cushion systems are rated by indices THIV and PHD. Crash test results are considered to study the performance of three crash cushion systems. In case of the frontal impact or the offset frontal impact, the results show that THIV values of three systems are very close to the threshold limit for the occupant protection. Also, the results show that PHD would be improper for the occupant protection performance index. In order to improve the occupant protection performance of crash cushions, ASI needs to be included in the impact severity index.

Effects of Haunch Reinforced Steel Moment Connection on Elastic Lateral Drift (헌치로 보강된 철골 모멘트 접합부의 탄성 횡변위에 대한 영향)

  • Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.1 s.30
    • /
    • pp.149-157
    • /
    • 1997
  • 철골 모멘트 접합부를 헌치로서 보강할 경우 내진거동이 크게 증진됨이 최근의 실물대 시험에서 입증되고 있다. 본 연구에서는 헌치로서 보강된 철골 모멘트 접합부가 골조의 탄성 횡변위 거동에 미치는 영향을 해석적으로 평가하는 방안을 제시하였다. 즉 내부의 보-기둥 부분골조를 대상으로 기둥, 보 및 이중패널존에서 기인하는 탄성 횡변위 성분을 해석적으로 유도하였다. 핵심이 되는 내용은 헌치 보강시 생성되는 이중패널존의 전단변형을 고려하는 것이었다. 제시된 방안에 의한 예측치는 3차원 유한요소해석에 의한 결과와 잘 부합하였다. 본 연구에서 수행한 사례연구에 의할 때 헌치의 도입으로 패널존의 강성증대가 가장 현저하여서 패널존의 전단변형에서 기인하는 탄성 횡변위가 50%정도 감소되었다. 본 연구의 결과는 아직 잘 알려지지 않은 헌치 보강에 따른 부차효과(side effects)의 이해에 도움이 될 수 있을 것이다.

  • PDF