• Title/Summary/Keyword: 실물

Search Result 1,327, Processing Time 0.024 seconds

The Determinants of Switching On·Off-Line Channels for Consumers (소비자의 온·오프라인 채널이동 유형의 결정요인에 대한 연구)

  • Jun, Sangmin
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.245-256
    • /
    • 2013
  • This study illustrates factors that determine consumer types based on ways in which they alternate between online and offline channels for searching and eventually buying their desired products. This study conducted an online survey targeting 1,040 consumers. As per the study, consumer types fall into five groups: 1) on-on type(online search${\rightarrow}$online buying), 2) off-off type(offline search${\rightarrow}$offline buying), 3) on-off type(online search${\rightarrow}$offline buying), 4) off-on type(offline search${\rightarrow}$online buying), and, 5) on-off-on type(online search${\rightarrow}$ offline search${\rightarrow}$nline buying). The primary factors that determine how the different consumer types switch between online and offline channels are price orientation, convenience orientation,, risk-aversion orientation, and channel familiarity. Although they feel cross-channel shopping can be cumbersome, the findings show that cross-channel consumers would gladly switch channels to buy cheaper and proven products. The findings of this study will be useful for businesses that have both online and offline channels and point out the theoretical aspects of the decision-making process as consumers switch between channels.

A Study on Remote Analysis of Fire Gas Using Open Path FT-IR (개방형 적외선분석기를 사용한 원거리 화재발생가스 측정에 관한 연구)

  • Cho, Nam-Wook;Lee, In-Gu;Lee, Jong-Cheon
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.39-45
    • /
    • 2013
  • The gas generated from the fire which is continuous until material is completely burned. We can analyze usual gas using chromatography analysis but it can not be applicated to analyze for the gas from the fire because which gas is enormously generated. Besides, chromatography analysis has the disadvantage that it can not continuously analyze the sample's representativness, gas from the fire, Fourier transform infrared spectroscopy, FT-IR, has been utilized for effective combustion gas analysis method in small-scale combustion and on-line analysis has been attempted continuously. However, continuous sampling of 3.5l/min can not be representativness of sample if the gas caused by a massive fire and space. And the gas sampling is practically impossible in such a case. In this study, we attempted remote analysis while overcoming the disadvantages of the current gas analysis by using an Open-Path Infrared Analyzer without pre-treatment of the sampling. For the remote analysis, quantitative analysis method was established regarding each combustion toxic gases. And we measured the gases from the fire that occurs in the real case.

Flame and Carbonization Patterns of Animal-Origin Foods Ignited by Overheating (과열에 의해 발화된 동물성 식품의 화염 및 탄화 패턴에 관한 연구)

  • Lee, Jeong-Hun;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.126-131
    • /
    • 2019
  • Real-scale fire tests were performed on animal-origin foods using a gas stove with no overheating prevention device. When the animal-origin foods were ignited, a large quantity of white smoke and steam was generated from them; however, when they became dry and began to carbonize, a dark smoke was generated. Even after the gas stove was overheated for more than 5400 s, mackerel, pollack, chicken, etc., did not ignite. However, pork, beef, and tuna caught fire after 2643 s, 2819 s, and 6492 s of heating, respectively. The flame patterns of animal-origin foods were in the forms of a mixed laminar flow and a turbulent flow, and a halo pattern was produced. A sand glass form of the flame pattern was generated when a kitchen hood was operated, but a triangular flame pattern was produced when the kitchen hood was not operated. When the tuna in the pot was overheated, it spontaneously ignited after 6492 s, with the surface temperature of the kitchen hood rapidly rising to 464.5 ℃. Moreover, the temperature at the back of the pot, which was 6 cm away from the outer surface of the upper part of the pot, was 869 ℃ after 6660 s because of the radiant heat. The flame formed a sand glass pattern on the kitchen wall. When the kitchen hood was not operated, or when the flame grew lower than the height of the ceiling, a triangular pattern was formed.

Experimental Study on Field Applicability of Tightened Coupler with Two-Way Threading (양방향 나사산 체결방식을 활용한 완전밀착형 커플러의 시공성 분석)

  • Park, U-Yeol;Hong, Seong-Wook;Yang, Jin-Kook;Ko, Suck-Hwa;An, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.1
    • /
    • pp.87-93
    • /
    • 2014
  • A tightened coupler with two way-threading is suggested to overcome the previous one-way threaded coupler. The experiment and a mock-up test were conducted to analyze the constructability of the suggested coupler. The aim of the mock-up test was to assemble the suggested coupler in horizontal rebar of mat footing and vertical rebar of semi-fabricated column bars. The method using the suggested coupler in semi-fabricated column bars is developed by analyzing the problem of fabricated column bars using the one-way threaded coupler. The result of the mock-up test showed that the time required to assemble the suggested coupler in the horizontal bars is shorter than it is for the one-way threaded coupler. In addition, the method using the suggested coupler in semi-fabricated column bars has advantages such as lower working loads, supporting safe work and strongly tightening the rebar. From these results, it is revealed that the suggested coupler is adequate to use in rebar work in terms of cost, quality and time.

Fabrication of Face Molds and Silicone Masks using 3D Printing (3D 프린팅을 이용한 얼굴 몰드 및 실리콘 마스크 제작)

  • Choi, Yea-Jun;Shin, Il-Kyu;Choi, Kanghyun;Choi, Soo-Mi
    • Journal of KIISE
    • /
    • v.43 no.5
    • /
    • pp.516-523
    • /
    • 2016
  • For old-age makeups, makeup artists first make a mold cast of an actor's face using plaster and then sculpt wrinkles in clay on the plaster mold. After finishing the clay sculpture, its negative plaster mold is fabricated and silicone skin patches are finally made for application to the actor's face. This process takes a few days and is tedious for actors and makeup artists. With recent advances in 3D printing and scanning technology, it is becoming easier to scan and fabricate 3D faces. This paper presents a new pipeline composed of facial scanning, interactive wrinkle modeling, and mold printing stages to easily and efficiently fabricate silicone masks for old-age makeups without the use of plaster and clay. An intuitive sketch interface based on a normal map is proposed for the creation of wrinkles in real time, even with a high-resolution face model. Then the geometry of the final wrinkles is reconstructed using a depth map and the negative mold of the wrinkled face is printed. We also show that the presented pipeline can fabricate a silicone mask more conveniently than the traditional one that consists of pouring silicone into the prepared negative mold and then overlapping the mold with the original positive one.

Applicability of High-strength Mass Concrete through Setting Time and Horizontally-divided Placement (응결시간제어용 배합과 수평분할을 고려한 고강도 매스콘크리트의 적용성 평가)

  • Cho, Seung-Ho;Paik, In-Kwan;Lee, Dong-Ha;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.103-113
    • /
    • 2017
  • In the current study, retarding type and standard type admixture design of concrete have been proposed to control the generation of hydration heat for foundation members that use high strengths concrete. Finite element analysis also has been conducted to understand the rational placing heights of concrete. In addition, real-size structures have experimented and their results were compared to the analytical results to evaluate the reducing effect of thermal stress. For a large $6.5m{\times}6.5m{\times}3.5m$ member with retarding and standard type horizontal partition placement of concrete showed the manageable possibility of temperature difference within 25-degree Celcius between the middle and surface portion while the maximum temperature was 77-degree Celcius. Also, temperature cracking index from the finite element analysis appeared to be 1.49 that predicts no formation of cracking due to the effects of temperature. Finally, it appeared that horizontal partition placement of retarding and standard type concrete has the significant effect of reducing the thermal stress that generated by the hydration heat in the high strengths mass concrete.

A Study on Flash Over Delay Effects on Applied Plate-Fire Spread Prevention Method at Sandwich Panels Structure (샌드위치패널 건축물 플래시오버 지연을 위한 화재확산방지플레이트 시공방법 연구)

  • Kim, Do-hyun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.79-87
    • /
    • 2017
  • Sandwich panels which are having the both sides are bonded with a heat insulating material with an iron plate are used as factories, warehouse structures as advantages of convenience in construction at economic efficiency of material cost. However, in a panel structure constructed by continuous joining of sandwich panels, a joint portion where a panel and a panel are connected is generated. The joint part is a part which is easily vulnerable to fire because flames easily flow into the melting and deformation of the iron plate during fire. The flames flowing into the panel induce diffusion of fire by rapid burning, causing damage of human life and property. In this research, we developed a flame spread prevention plate to prevent spreading of sandwich panel. This is an improvement of the workability by the anti-spreading construction method of the existing previous research, it can be applied independently to the connecting part where the panel and the panel are coupled, designed to prevent inflow and spreading of flame did. The actual fire test of the test method of KS F ISO 13784-1 of the sandwich panel specimen was conducted and the burning behavior corresponding to the presence or absence of application of the flame spread prevention plate was grasped at the panel connection part and its effect was measured. Inserting a fire spreading plate into the test result panel connecting part is measured by delaying the flashover, prevention of collapse of the specimen, and temperature rise of the opening, effectively improving the fire safety of the panel structure It was confirmed as a method that can be secured. It is judged that panel structure will contribute to ensuring fire safety by applying the fire spread prevention construction method of various methods ensuring the workability and economy of panel connection vulnerable to fire.

Characteristics and Economic Effects of Korean Firms' R&D Investment (우리나라 민간기업 연구개발투자의 특성 및 경제적 효과)

  • Suh, Joonghae
    • KDI Journal of Economic Policy
    • /
    • v.27 no.1
    • /
    • pp.81-122
    • /
    • 2005
  • The paper aims to establish the characteristics of the Korean firms' R&D investment and to estimate the private rate of return to R&D investment. For the empirical analysis, a balanced panel data is constructed with 695 firms on 8 year observations. The panel data enables to characterize R&D investment of the Korean firms, which is mostly conformed to the 'stylized facts' of R&D investment that found in the previous studies on foreign firms. Klette model was used to estimate the private rate of return on R&D investment and depreciation rate of R&D capital. The paper estimates that the rate of return on R&D investment is 10.5% on average or 16.4% on median for the whole industry whereas manufacturing firms show 10.4% on average or 16.4% on median. The depreciation rate was estimated about 32.9% for whole industry, where it ranges from the minimum 11.6% for metal industry and 49.5% for services. The median estimate of the rate of return for R&D investment of Korean firms is roughly two times higher than real interest rates for the same period, which implies that R&D investment allows sizable rent in addition to the opportunity cost of capital investment.

  • PDF

Money and Capital Accumulation under Imperfect Information: A General Equilibrium Approach Using Overlapping Generations Model (불완전(不完全)한 정보하(情報下)의 통화(通貨)의 투자증대효과분석(投資增大效果分析): 중복세대모형(重複世代模型)을 이용한 일반균형적(一般均衡的) 접근(接近))

  • Kim, Joon-kyung
    • KDI Journal of Economic Policy
    • /
    • v.14 no.1
    • /
    • pp.191-212
    • /
    • 1992
  • This paper discusses the role of money in the process of capital accumulation where financial markets are impeded by contract enforcement problems in the context of overlapping generations framework. In particular, in less developed countries (LDCs) creditors may know little about the repayment capability of potential debtors due to incomplete information so that financial instruments other than money may not acceptable to them. In this paper the impediments to the operation of the private finanical markets are explicitly modelled. We argue that creditors cannot observe actual investment decisions made by the potential borrowers, and as a result, loan contracts may not be fully enforceable. Therefore, a laissez-faire regime may fail to provide the economy with the appropriate financial instruments. Under these circumstances, we introduce a government operated discount window (DW) that acts as an open market buyer of private debt. This theoretical structure represents the practice of governments of many LDCs to provide loans (typically at subsidized interest rates) to preferred borrowers either directly or indirectly through the commercial banking system. It is shown that the DW can substantially overcome impediments to trade which are caused by the credit market failure. An appropriate supply of the DW loan enables producers to purchase the resources they cannot obtain through direct transactions in the credit market. This result obtains even if the DW is subject to the same enforcement constraint that is responsible for the market failure. Thus, the DW intervention implies higher investment and output. However, the operation of the DW may cause inflation. Furthermore, the provision of cheap loans through the DW results in a worse income distribution. Therefore, there is room for welfare enhancing schemes that utilize the higher output to develop. We demonstrate that adequate lump sum taxes-cum-transfers along with the operation of the DW can support an allocation that is Pareto superior to the laissez-faire equilibrium allocation.

  • PDF

Confining Effect of Mortar Grouted Splice Sleeve on Reinforcing Bar (모르타르 충전식 철근이음과 구속효과)

  • Ahn, Byung-Ik;Kim, Hyong-Kee;Park, Bok-Man
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.102-109
    • /
    • 2003
  • The grouted splice steeve has been applied widely due to its superior construction efficiency, such as the unnecessity of post concrete and the large allowable limit to the arrangement of reinforcing bars. However, studies on grout-filled splice steeve still have not been sufficiently peformed. The purpose of this study is to investigate the confining effect of mortar grouted splice sleeve on reinforcing bar, known to strengthen the bond capacity between grout mortar and reinforcing bar. To accomplish this objective, totally 6 full-sized specimens were made and tested under monotonic loading. Each specimens were equipped with strain gauges at the 12 location of sleeve and reinforcing bar. The experimental variables adopted in this study are embedment length and size of reinforcing bars. Following conclusions are obtained; 1) Under ultimate strength condition, the confining pressure of grouted splice sleeve calculated from measured tangential and axial strain of the sleeve is over $200{\sim}300kgf/{cm}^2$ at any location of sleeve and improved with reduction in embedment length of reinforcing bar. 2) Untrauer and Henry's equation which describe bond strength of mortar as a function of its compressive strength and confining pressure, predicted the measured bond capacity of this test within the 5% limits.