• Title/Summary/Keyword: 실물실험

Search Result 504, Processing Time 0.023 seconds

Development and Application of Swatch Materials for Clothing and Textiles Education in Middle School (중학교 가정과 교육 의복재료 단원을 위한 실물 교육자료 개발 및 적용)

  • Kim, Ji-Sun;Hong, Kyung-Hwa
    • Journal of Korean Home Economics Education Association
    • /
    • v.26 no.1
    • /
    • pp.55-68
    • /
    • 2014
  • The study aims to develop teaching and learning media to raise up learners' interests and understanding during clothing class by providing a clothing swatch materials and its guide for applying to the unit of clothing in technology and home economics subject in middle school. To do so, clothing swatch materials, study sheet and guide were developed, applied and then analyzed for their effects. In this study, in order to figure out effects of class using clothing swatch materials on learning interest, learning necessity, learning understanding and academic achievements, the experiment was conducted for comparing and analyzing the learning interest, learning acceptance attitude and academic achievement between experiment group with using clothing swatch materials and control group without using the materials. The results of the study are as follows: First, the experiment group using clothing swatch materials shows higher learning interest than the control group without materials. Second, the experiment group showed higher learning acceptance attitude than the control group. Third, the experiment group achieved higher academic accomplishments than the control group.

  • PDF

A Study for the Reinforcement of Concrete Beam and Slab with Composite Beam (복합재료보를 이용한 콘크리트 보와 슬래브의 보강에 대한 연구)

  • Kwon, Min-Ho;Kim, Doo-Kie;Shin, Hong-Young;Kim, Ki-Hong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.255-258
    • /
    • 2009
  • 본 논문에서는 최근 건축구조물의 보수보강에 사용되고 있는 복합재료보의 정확한 보강성능을 규명하기 위하여 다양한 실물 실험을 수행하였으며 실험 결과를 검토하여 실제 보강효과를 검증하였다. 콘크리트의 재료비선형을 고려할 수 있는 수치해석 기법으로 실험결과를 재현하여 보강효과를 수치해석적으로 검증하였으며 복합재료보를 이용하였을 경우 확보할 수 있는 보강효과에 대하여 연구하였다. 일반적인 철근콘크리트 구조물에 복합재료보를 이용하여 보강하였을 경우, 약 80% 내외의 하중 증가효과를 확보할 수 있었다. 또한 수치해석을 통하여 보강효과를 검토한 결과, 실물실험과 유사한 결과를 얻을 수 있었으며 복합재료보의 시공시 사용되는 전단연결재의 효과를 고려한다면 거의 동일한 결과를 얻을 수 있을 것으로 판단된다. 현재까지의 연구결과, 복합재료보를 이용하여 구조물을 보강한 경우, 취성이 증가하는 것으로 알려져있으나 추가적인 연구를 통하여 연성을 확보할 수 있는 복합재료보의 연구개발이 가능할 것으로 예상된다.

  • PDF

Experimental and Numerical Study of Smoke Movement in Tunnel Fires (터널 화재 시 연기전파에 대한 실물실험 및 수치해석적 연구)

  • Lee Seung-Chul;Lee Seung-Ho;Kim Nam-Young
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.341-347
    • /
    • 2005
  • 본 논문은 터널에서 화재 발생 시, 시간에 따른 연기거동에 대해 실물실험과 3차원 수치해석을 수행하고 각각의 결과를 비교,검토하였다. 실물실험을 위하여 8.8 kW의 열원과 901iter/h의 연기 발생이 가능한 연기발생장치를 자체 제작하였으며, 대상터널은 길이 570m, 단면적 $64.6m^2,$ 그리고 약 $2\%$의 구배를 가지고 있다. 실험은 외풍의 영향을 줄이기 위해 터널 입,출구에 차단막을 설치하였으며 연기발생장치로부터 20m 간격의 위치에서 20초 간격으로 연기전파, 속도 그리고 온도를 측정하였다. 연기는 60초 경과 후, 연기발생장치로부터 20m 떨어진 위치에 도달하였으며 140초, 180초 및 260초 경과 후, 각각 40m, 60m 및 80m 위치에 도달하였다. 3차원 수치해석의 결과는 터널벽면을 매끈한 표면으로 처리하였을 때, $26.3\~49.5\%$정도 과대 예측하였다. 또한 터널벽면을 일정 조도를 갖는 거친 표면으로 처리한 경우는 $-2.7\~17.6\%$ 오차로 실험결과에 보다 근접하는 결과를 보였다. 따라서 터널 내 연기거동에 대한 3차원 수치해석을 수행할 때에는 벽면조도에 대한 고려가 필요하리라 판단된다.

  • PDF

The Real Scale Fire Test in Tunnel for Fire Detector Performance Evaluation (터널에서의 화재 감지기 성능 평가를 위한 실물화재실험)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.96-101
    • /
    • 2010
  • 본 연구에서는 터널 내부에서의 화재 사고 시 화재를 자동으로 조기 발견 경보하여 화재 초기에 대응력을 확보시킬 수 있게 하는 화재 감지기의 성능 평가를 위해 터널 내부에서의 실물 화재 실험을 실시하였다. 실물화재실험은 일반적으로 도로 터널에 적용 중인 공기관식, 반도체식 감지기를 대상으로 "도로터널 방재시설 설치지침(2004, 건설교통부)"의 터널 내부의 화재 감지기 성능 실험 기준에 따라 메탄올을 이용한 풀버너와 소형 승용차를 이용하였다. 실험결과 메탄을 풀화재(단면적 $4m^2$)의 경우 약 36초 안에 모두 화재를 감지하였으며, 실물자동차화재실험의 경우는 1분 이내에 모두 화재를 감지하는 결과를 나타내었다.

  • PDF

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.171-174
    • /
    • 2010
  • 도로터널에서의 미분무수 소화시스템의 적용 가능성을 검토하기 위해 실물 화재 실험을 수행하였다. 적용된 화원은 실물 승용차 화재와 유류화재를 모사한 화원면적 $1.4m^2$의 heptane pool 화재이며, 기존 도로터널에 설치된 저압 물분무 시스템과 고압 미분부수 소화시스템과의 냉각효과 비교실험을 수행하였다. 도로터널 내의 환기조건을 구현하기 위해 실물모형 터널의 한 편에 터널 유속(0.9~3.8 m/sec 범위) 발생장치를 설치하였으며, 화원에서 하류 방향으로 터널 내 온도분포를 측정하였다. 실험 결과 1/5의 유량을 사용하는 고압 미분무수 소화시스템은 저압 물분무 시스템과 동등한 수준의 냉각효과를 보였다.

  • PDF

A study on the vehicle fire property using the large scale calorimeter (대형칼로리미터를 이용한 차량 화재 특성에 관한 연구)

  • Yoo, Yong-Ho;Kim, Heung-Youl;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.343-349
    • /
    • 2007
  • The reduced scale fire test provides basic data but it is not enough to analysis real fire problem directly because there is no exact analogy theory between a real fire and the reduced scale model. Therefore we have developed the large scale calorimeter in order to the real scale fire test. This advanced large scale calorimeter used for physical properties such as a heat release rate, based upon consumption of $O_2$ method. Using this large scale calorimeter, we cameo out the real scale vehicle fire test in order to evaluation for heat release rate. We obtained the calculated result for HRR $2.3{\sim}3.4\;MW$ and this result is very similar to the PIARC candidate HRR. It is approve that this facility has the reliability and it is capable of applying to the advance fire research in the future.

  • PDF

An Experimental Study on the Warehouse Mock-up Fire Test (창고 모델 실물화재 특성에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.47-54
    • /
    • 2010
  • This study is analyze the damage of warehouse fire accident be made through the fire characteristic database of combustibles and real scale fire test of warehouse mock-up. Combustibles fire tests are carried out for database using RCT (Room Corner Tester) to predict fire growth the goods. A mockup ($3m{\times}3m{\times}2.4m$) of clothes warehouse was built and real scale fire test by LSC (Large Scale Calorimeter) base on the fire characteristic DB. The mock-up of clothes warehouse is made of two type sandwich panels (Glass wool, EPS foam sandwich panel). As a mock-up test result, test 1 (Glass wool sandwich panel) and test 2 (EPS foam sandwich panel) indicating fire growth such as 5 MW, 11 MW of maximum HRR (Heat Release Rate).

The Real Scale Fire Test for Unit Space in Apratment housing (공동주택의 단위공간 실물화재실험)

  • Yoo, Yong-Ho;Kweon, Oh-Sang;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.346-351
    • /
    • 2009
  • 본 연구에서는 화재시 많은 인명피해가 예상되는 공동 주택을 대상으로 단위공간별 화재 성상을 예측하기 위한 실물화재실험을 실시하였다. 구성된 실물화재모델은 비교적 가연물량이 많은 침실과 화재 발생 위험도가 높은 주방을 대상으로 하였으며, 실험 모델에 구성된 단위품목은 일반주택의 가연물을 선조사 한 후 선정하였다. 실험결과 침실의 경우 점화 후 약 5분이 경과되었을 때 플래쉬오버 상태에 이르게 되어 매우 급격한 성장을 보였으며, 최대 열방출율 약 7433.3 kW, 최대 일산화탄소 578.6 ppm, 최대 이산화탄소 1.25ppm, 내부 최대온도 1350$^{\circ}$로 측정 되었다. 특히, 화재 발생 초기에 가연 공간에서 화재의 진화가 이루어지지 않으면 약 3분 내에 인체에 급격한 피해를 줄 수 있는 한계온도 이상으로 화재가 성장하기 때문에 신속한 초기 대응이 필요함을 확인하였다. 이러한 실물화 재실험에서 얻어낸 결과는 향후 화재확대 예측 시뮬레이션 결과와 비교함으로써 각 용도별 공간에서의 화재 확산 예측에 적용 될 수 있을 것이다.

  • PDF

The Study on Real Scale Fire Test for Fire Growth of Office (사무용 공간의 화재 성장 예측을 위한 실물화재실험)

  • Kweon, Oh-Sang;Kim, Heung-Youl;Kim, Jung-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.278-281
    • /
    • 2012
  • 사무공간의 화재성상을 예측하기 위해 화재하중 $25kg/m^2$ 값을 적용하여 $2.4(L){\times}3.6(W){\times}2.4(H)\;m$ 크기의 Mock-up 화재실험을 진행하였다. 화재실험은 실물화재실험 장비인 LSC(Large Scale Calorimeter)에서 실시하였으며, 열방출률 및 질량감소율을 측정하였다. 실물화재실험 시작 후 약 1110 초에 플래시오버가 발생하였으며, 최대 열발출률은 1241.1 KW로 측정되었고 질량은 초기 219 kg에서 102 kg로 감소하였다.

  • PDF

A Study on Concentration Change of Volatile Organic Compounds; VOCs by using Mock-up Test (실물실험을 통한 개별 VOC의 농도변화에 관한 연구)

  • Kim Chang-Nam;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.487-495
    • /
    • 2005
  • Recently, due to the airtightness of buildings or the misuse of building materials, we have been witness SHS (Sick House Syndrome) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. As a result of this situation, we went to restrict the TVOC (Total Volatile Organic Compound) and formaldehyde. But these guidelines concentrated on only TVOC although TVOC are consist of many individual VOC. Therefore, in this study, we will look about concentration change of VOCs (Volatile Organic Compounds) by using Mock-up test. As result of test, the concentration of four individual VOC (Benzene, Toluene, Ethylbenzene, Styrene) showed quitely low level after 7 days. On the other hand the concentration of Xylene and formaldehyde showed low level after 14 days.