• Title/Summary/Keyword: 실동응력

Search Result 14, Processing Time 0.024 seconds

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Histogram Recorder System에 의한 측정예

  • Han, Eung-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 1985
  • 차량, 항공, 교량 및 기계구조물 등 랜덤한 실동하중을 받는 구조물의 응력 및 변위, 진동등의 피로 Data 또는 TRAFFIC 등에 의한 건축물의 변위 및 응력발생빈도를 집록하기 위한 Histogram Recorder System에 대한 내용과 측정예를 소개하고자 한다. 본 System은 8(4)챈 널의 스트레인 게이지 또는 스트레인 게이지식 각종변환기와 각종 Sensor로부터의 출력전압 등 Analog 입력을 수록하여, Digital 처리하여 micro computer를 사용, 미리 프로그램된 방식에 따라 측정과 동시에 실동시간으로 해석처리하여 빈도수로서 내부에 기억저장 시키는 것이다. 따라서 본 Histogtram Recorder 본체는 소형으로 견고하며 조금도 제어부분을 갖지 않고 소요의 해석방법의 프로그램백만을 셋트한 개별의 제어기만을 통해가지고 프로그램을 기입만 하며는 그다음은 손하나 안대고도, 그리고도 또 측정중에 제3자에 의한 제어조작 잘못이 발생할 위험도 없고 1 년이상에 걸친 장기간의 .+-. 32 Slices의 각 레벨당 각각 40 억을 넘는 대량의 빈도수를 자동적으로 집록 할 수가 있다. 집록된 Data는 제어장치에 의해 정리된 Datam는 제어장치에 의해 정리된 Histogram의 형태로 읽어나갈 수가 있어 관찰이 가능할 뿐만 아니라 프린터기록 또는 기록장치에 이송시켜서 Data 만 따로 가져올 수가 있어 필요에 따라서는 one line으로 Host computer에 접속시킬 수가 있어 더욱 고도의 처리를 할 수가 있다. 빈도해석프로그램으로서는 극대, 극소, 최대, 최소, 진폭, 시간 등을 pack으로서 준비되어 있어 이에 대한 시스템의 고성 동작 및 성능등을 소개하고자 한다.

  • PDF

Evaluation of Total Serviceable Life of Bogie Frame of Electric Multiple Unit by Dynamic Strain Measurement (실동응력 측정을 통한 전동차 대차프레임의 내구수명 평가)

  • Kim, Seung-Sub;Han, Seong-Uk;Park, Geun-Soo;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.277-282
    • /
    • 2011
  • Bogie frame is typical safety part of railway vehicle. Total serviceable life of bogie frame will be evaluated by Cumulative Damage Approach Method that is defined by dynamic strain measurement during revenue service under the actual track conditions. As a result of the standardization process developed in British Standard Institution, BS 7608 defines for fatigue design and test method of steel structure by fatigue test results over the long period. This paper evaluates the total serviceable life applying BS 7608 for the bogie frame of Electric Multiple Unit to verify structural safety of the bogie frame.

  • PDF

Repair of Fatigue Damage of Coped Stringers in Railway Truss Bridge (트러스 철도교에서 피로손상이 발생한 절취된 세로보의 보강방법)

  • Kim, Ki-Du;Jeon, Jun-Chang;Hwang, Yoon-Koog;Chang, Dong-Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.95-103
    • /
    • 1996
  • 단순 전단연결 구조를 가진 강철도교의 세로보 단부의 절취부위에서 많은 피로균열이 발견되었으며, 이러한 부위의 피로균열은 피로손상의 전형적인 예이다. 피로균열을 가진 세로보 절취부위의 보강방법을 연구하기 위하여 가로보 및 세로보의 상부 플랜지에 인장판을 부착한 경우와 부착하지 않은 경우로 구분하여 피로실험을 수행하였다. 피로실험에 사용된 하중은 현장에서 측정된 실동응력을 기초하여 빈도해석을 통해 산정하였다. 피로실험 결과, 인장판으로 보강한 모멘트 저항 연결구조상세가 철도교에서 균열성장을 효과적으로 정지시킬 수 있는 것으로 판명되었으며, 피로손상을 가진 절취부위의 보강방법으로 제시될 수 있을 것으로 사료된다.

  • PDF

Remaining Fatigue Life Evaluation of Steel Railroad Bridge (강철도교의 잔존피로수명 평가)

  • Kim, Sang Hyo;Lee, Sang Woo;Mha, Ho Seong;Kim, Jong Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.4 s.41
    • /
    • pp.329-338
    • /
    • 1999
  • A systematic procedure to evaluate fatigue damages and to predict remaining fatigue lives is introduced for a steel railway bridge. Fatigue damages are evaluated by using the currently available fatigue damage theory. Fatigue lives with the condition of fatigue crack initiation are estimated by the probabilistic approach based on the reliability theory as well as the simplified procedure. A equivalent deterministic procedure is also suggested to assess the remaining fatigue life under various traffic conditions. Numerical simulations are used to assess dynamic stress histories with correction factors. Loading models are obtained from the passenger volume data. Train coincidences are also considered. Based on the results, the fatigue life is found to be underestimated by without considering the coincidence of trains on the bridge. The simplified method proposed in this study are found to yield approximately the same results as the systematic procedure.

  • PDF

Stress Histogram Analysis of Steel Plate Girder Railway Bridge due to Service Load Histories (실동하중에 의한 강판형철도교의 응력빈도해석)

  • Hwang, In-Gu;Kim, Yeon-Tae
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.928-933
    • /
    • 2004
  • Despite the number of steel bridges being under in service more than 50 years reaches about 50$\%$ in present, the quantitative estimation in maintenance on steel railway bridges is not possible because a ton of the field data in the bridges have not been plentifully accumulated. Therefore, a series of field tests on the steel plate girder bridge, the typical types of steel railway bridges, are executed, and the stress characteristics of main members in steel plate girder railway bridges are quantitatively estimated in this study.

  • PDF

Fatigue Life Evaluation of Motor Block Bracket Units for KTX-Sancheon Trains (KTX-산천 열차용 모터 감속기 고정대의 피로 수명 평가)

  • Lee, Chan-Woo;Lee, Dong-Hyong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.626-631
    • /
    • 2012
  • In this study, fatigue life of the motor block bracket units for KTX-Sancheon trains was assessed. Design evaluation for railway structures was performed based on the UIC 566 regulation, and test and evaluation of fatigue life in welded parts was performed in accordance with standard ERRI B 12/RP17 and ERRI B 12/RP60. The actual vehicle dynamic stress testing was executed in KTX-Sancheon service line with the service operating speed. The dynamic stress was measured with commercial data acquisition system (MGC plus). The cumulative damage was evaluated by applying standard BS 7608 - Class F and cycle counting was used rain-flow counting method. As a result, the motor block bracket units for KTX-Sancheon trains was designed to fit the regulation and the safety of fatigue life for 30 years, assuming that KTX-Sancheon trains travels 600,000km annually, were confirmed under current operating conditions.

Analysis of Practical Dynamic Force of Structure with Inverse Problem (역문제에 의한 구조물의 실동하중 해석)

  • 송준혁;노홍길;김홍건;유효선;강희용;양성모
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.75-80
    • /
    • 2004
  • Vehicle structures are composed of many substructure connected to one another by various types of mechanical joints. In vehicle engineering it is important to study these connected structures under various dynamic forces for the evaluations of fatigue life and stress concentration exactly. It is difficult to obtain the accurate load history of specified positions because of the errors such as modeling, measurement and etc. In the beginning of design exact load data are actually necessary for the fatigue strength and life analysis to minimize the cost and time of designing. In this paper, the procedure of practical dynamic force determination is developed by the combination of the principal stresses of F. E. Analysis and experiment. Least square pseudo inverse matrix is adopted to obtain in inverse matrix of analyzed stresses matrix. The error minimization method utilizes the inaccurate measured error and the shifting error that the whole data is stiffed over real data. The least square criterion is adopted to avoid these non. Finally, to verify the proposed procedure, a bus is analyzed. This measurement and prediction technology can be extended to the structural modification of any geometric shape in complex structure.

The Fatigue Evaluation of Structural Steel Members under Variable-Amplitude Loading (변동하중을 받는 강구조부재의 피로거동 해석)

  • Chang, Dong Il;Kwak, Jong Hyun;Bak, Yong Gol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.167-175
    • /
    • 1988
  • The principle objective of this study is to evaluate the fatigue behavior of structural steel components of highway bridges subjected to service stresses. The main aspects of this investigation are; 1) a measurement and statistical analysis of service stress cycles observed in highway bridge. 2) fatigue tests under equivalent constant-amplitude(CA) loading and simulated variable-amplitude(VA) loading 3) a evaluation of the fatigue behavior under VA-loading by eqivalent root mean cube (RMC) stress range. Theoretically, the RMC model is adequate in evaluation of fatigue behavior under VA-loading, because the regression coefficient (m) of crack growth rate is 3 approximately. The result of fatigue test shows that the RMC model is fitter than the current RMS model in fatigue evaluation under VA-loading. The interaction effects and sequence effects under VA-loading affect little fatigue life of structural components. As the transition rate of stress ranges is higher, the crack growth rate is higher.

  • PDF

Characteristic and Analysis of Fatigue Crack for Curved Girder Bridge based on the Stress Range Histerisis (실동이력에 기초한 곡선거더교의 피로균열 특성 및 분석)

  • Kwon, Soon Cheol;Kyung, Kab Soo;Kim, Da Young;Lee, Ha Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.1-13
    • /
    • 2008
  • The web of a horizontally curved plate girder bridge is, in general, subject to not only longitudinal flexural in-plane stress but also out-of-plane bending stress. Therefore, the induced stresses in the fillet welded joints at the intersection of the web and flange plates in the curved plate girder bridge can be considerably high, and the welded joints of gusset plates connecting the main girder to the floor beams or sway bracings can be subject to much more severe situation than those in the ordinary straight plate girder bridge. In order to investigate the cause of fatigue crack occurred in a curved girder bridge that has been served in about 23 years, in this study, field load tests have been performed to obtain the stress characteristics at the welded joint under the real traffic flow. Using the test results, we have investigated the causes of the occurrence of various fatigue cracks and have estimated the fatigue lives for the cracks. In addition, the characteristics of structural behavior at welded joint of the curved girder bridge have been examined by comparing the FE analysis and the field test result.