실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구 (A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality)

  • 이용준;이승복;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

공동주택의 피난안전성 강화를 위한 배기시스템 활용 방안 연구 (Application Plan of Exhaust Systems in Strengthening Evacuation Safety in Apartment Houses)

  • 이현상;윤명오;이영주;김정준
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.49-57
    • /
    • 2020
  • 공동주택은 과학의 발전과 도시의 랜드마크적 상징성으로 점점 고층화 고밀화되어 가고, 입주민의 삶의 질 향상을 위해 각종 편의시설과 안전시설도 함께 발전되어 가고 있다. 그러나 통계자료에 의하면 공동주택은 사고 발생 대비 사상자가 높은 비중을 차지하고 있으며, 사상자의 주요 피해 원인은 심야 시간에 수면 상태에서 화재를 늦게 인지하여 연기에 의하여 많은 인명피해가 발생하고 있다. 공동주택에서 재실자의 연기피해를 최소화하기 위하여 실내에 별도의 배연 시설을 설치하는 것이 가장 최선의 방법이지만, 입주자의 경제적 부담을 줄이면서 현재 설치된 시설물을 활용하여 연기피해를 최소화하는 것이 공학적 입장에서 유용한 조치라고 판단된다. 검토 결과 전열교환환기방식과 주방공용배기방식을 선정하여 화재 시뮬레이션을 통하여 실증 여부를 검증하였다. 검증결과 피난허용시간(ASET)이 25층은 27 s, 35층은 30 s, 50층은 35 s가 향상되었다.

국내 터널식환기 무창 육계사에서 여름철 쿨링패드 사용에 따른 계사 내부 온도 저감 효과 및 더위지수(THI)에 미치는 영향 (Effects of Pad Cooling Systems in Tunnel-Ventilated Broiler House on Reducing Indoor Temperature and Level of Temperature-Humidity Index during Summer)

  • 김혜란;박설화;위지수;이성신;이성대;강환구;류채화
    • 한국가금학회지
    • /
    • 제51권2호
    • /
    • pp.57-63
    • /
    • 2024
  • 전세계적인 기후변화로 인해 국내 평균기온과 여름철 폭염 강도가 심화되면서 고온스트레스로 인가축 피해를 완화하기 위한 사양 전략이 필요한 상황이다. 국내육계사의경우 터널식 환기계사나 쿨링패드 등 시설을 설치하여 여름철 실내온도를 저감하고 있다. 그러나 쿨링패드의 경우 계사내부의 습도를 증가시켜 역으로 피해를 유발할 수 있어 사용시 주의를 요한다. 따라서 본 연구에서는 국내의 대표적 계사 형태인 터널식 환기 무창 육계사에서 쿨링패드를 가동시 계사 내부의 온도 저감 효과를 더위지수(temperature-humidity index; THI)로 함께 평가하고자 하였다. 본 연구에서는 우리나라의 각각 다른 지역에 위치한 8개의 터널식 환기 무창계사 육계농가를 대상으로 여름철(6~9월) 온도와 습도 데이터를 수집하였다. 해당 농가들은 쿨링패드의 유무에 따라 2개의 처리군으로 나뉘었으며, 출하 2주 전 기준으로 온습도 데이터를 추출하여 계사 내·외부간 온습도 및 THI의 편차를 구하였다. 메타분석 결과, 여름철 가장 더운 낮시간대인 14시를 기준으로 대조구 대비 쿨링패드 보유 농가에서 내외부 온도의 차이가 크고, 해가 지는 16시대에 내외부 온도의 차이가 줄어드는 것으로 관찰되었다(P<0.05). 쿨링패드에 따른 상대습도에 대한 유의적인 차이는 없었으나(P>0.05), 스트레스를 수치화한 THI 지수로 환산하였을 때, 오후 3시부터 대조구 대비 쿨링패드 보유 처리구가 THI 편차 값이 감소하여 효과가 줄어드는 것으로 판단되었다(P<0.05). 본 연구의 결과 14시 쿨링패드를 보유한 농가는 쿨링패드가 없는 대조구 농가보다 계사내외부 온도차가 크게 나타났고, 이는 계사내부 온도저감에 효과가 있다고 판단할 수 있다. 따라서 쿨링패드 사용시 계사내 더위피해를 저감하는 데 효과가 있을 것으로 생각되며, 본 연구의 결과는 하절기 육계의 고온스트레스 저감을 위해 쿨링패드 운용시 참고자료로 활용할 수 있을 것으로 생각된다.

포그노즐을 이용한 온실냉방시스템 분석 (Fog Nozzle-Greenhouse Cooling System Analysis)

  • 김영중;유영선;윤진하;오권영;김승희
    • 생물환경조절학회지
    • /
    • 제6권1호
    • /
    • pp.48-54
    • /
    • 1997
  • 하절기 고온으로 인한 작물의 열악한 생육 환경개선을 위하여 미포그노즐을 이용하여 패트온실에서 증발 냉각 시험을 수행하였다. 본 연구에 사용된 미포그노즐의 분무특성을 말븐입자분석기로 분석한 결과 분무압 70kg/$\textrm{cm}^2$에서 분무입자의 크기는 평균 27$\mu\textrm{m}$로 나타났고, 이때의 분무량은 분당 100$m\ell$였다. 또한 평균 분무 입자의 크기가 27$\mu\textrm{m}$인 경우에 분무낙하량을 조사한 결과 낙하거리 150cm에서 총분무량의 88%가 공중에 부유하는 것으로 나타났다. 냉방시스템의 주요 구성 부분은 고압노즐, 양수펌프, 필터 및 미포그노즐 32개로 이루어졌고, 1분 분무-1분 환기로 이루어진 연속 분무 시험 결과 외기온 3$0^{\circ}C$의 조건에서 온실내 기온을 4$0^{\circ}C$에서 32$^{\circ}C$로 강하시킬 수 있었다 또한 분무시험시 측정한 온실내의 온습도 값을 psychrometric equation에 대입하여 온실내의 수분변화량을 분석할 수 있었으며, 이와 같은 분석을 통하여 온도강하정도와 온실내 공기의 절대습도비 변화량을 예측할 수 있는 실험식을 정립할 수 있었다. 이 실험식을 이용하여 우리 나라 표준형 온실 1-2W, 3-2G-3S에서 실내온도를 4$0^{\circ}C$에서 3$0^{\circ}C$로 강제 냉각시킬 때 필요한 분무수량을 분석한 결과 분무입자 27$\mu\textrm{m}$에서의 분무수량은 각각 80.7, 99.9$\ell$였으며, 포그시스템에 필요한 노즐의 수는 분당분무량 100$m\ell$의 경우 3분 분무기준으로 각각 270, 333개가 소요될 것으로 계산되었다. 앞으로 포그시스템을 활성화하기 위해서는 온실의 기상조건에 따른 증발율과 분무입자에 대한 심층적 연구가 요망된다.

  • PDF

다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구 (Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility)

  • 김태한;최부헌
    • 한국조경학회지
    • /
    • 제48권5호
    • /
    • pp.80-88
    • /
    • 2020
  • 2019년 3월 미세먼지 비상저감조치가 일주일 동안 발령되면서, 미세먼지로 인한 국민의 불안감은 점차 가중되고 있다. 본 연구는 공기정화식물이 적용된 바이오필터의 다중이용시설 내 적용성 평가를 위해 입자상 오염원의 실내 연속방출환경을 조성하여 오염원 저감효과에 대한 측정방법을 제안하고, 시스템의 실내공기질 개선 여부를 확인할 수 있는 기초연구를 진행하였다. 강의실을 대상으로 춘절기에 모니터링 1시간 전 모기향을 오염원으로 배경농도를 조성한 후, 스케줄에 따라 2시간 관수, 1시간 송풍하여 미세먼지의 저감능을 확인하였으며, 바이오필터 2m 전방에 PM10, PM2.5 및 온습도 센서를 설치하고, 3개 송풍구 중 중앙에 풍속 프로브를 설치하여 시계열 모니터링을 수행하였다. 바이오필터에 구비된 총 3개소의 송풍구 평균 면풍속은 0.38±0.16 m/s로 댐퍼 면적이 제외된 송풍구별 면적 0.29m×0.65m을 적용한 총 공조풍량이 776.89±320.16㎥/h로 산출되었다. 시스템 가동으로 평균온도 21.5~22.3℃, 평균상대습도 63.79~73.6%를 유지하여, 선행연구의 다양한 조건별 온습도 범위에 부합하는 것으로 판단된다. 시스템 공조부 구동을 통해 급격하게 상대습도를 상승시키는 효과를 효율적으로 운용할 경우, 계절에 따른 실내 미세먼지 저감과 적정한 상대습도 확보도 가능할 것으로 판단된다. 미세먼지 농도는 바이오필터 시스템 가동 전의 모든 주기에서 상승 현상이 동일하게 집계되었으며, 시스템 가동 후 1주기 송풍구간(B-1, β=-3.83, β=-2.45)에서 미세먼지(PM10)는 최대 28.8% 수준인 560.3㎍/㎥, 초미세 먼지(PM2.5)는 최대 28.0% 수준인 350.0㎍/㎥까지 저감되었다. 이후 미세먼지(PM10, PM2.5)의 농도는 2주기 송풍구간 감소(B-2, β=-5.50, β=-3.30)로 각각 최대 32.6% 수준인 647.0㎍/㎥, 32.4% 수준인 401.3㎍/㎥까지 저감되었고, 3주기 송풍구간감소(B-3, β=5.48, β=-3.51)로 최대 30.8% 수준인 732.7㎍/㎥, 31.0% 수준인 459.3㎍/㎥까지 저감된 것으로 확인되었다. 본 연구는 식생 바이오필터의 다중이용시설 내 설치와 유관한 관련 표준 및 규정을 참조하여, 객관적인 성능평가환경의 구축 방안을 제시할 수 있었다. 이를 통해 일반 강의실 환경 내에 보다 객관화된 모니터링 인프라를 조성하여, 상대적으로 신뢰성 있는 데이터 확보가 가능했던 것으로 판단된다.

교육시설의 공기환경 실측에 관한 연구 (A Study on the Measurement of Indoor Air Pollutants in High School Building)

  • 김선정;김병수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1392-1397
    • /
    • 2008
  • This study is to measure the change of the $CO_2$ and floating dust concentration depending on the volume of the ventilation and the state of on/off the ventilation for the estimation of the air pollution in classroom. The results could be summarized as follows: the test cell was the two full scaled model and the one is set up with ventilation system another was not. the volume of classroom is 170.1m3 and the number of persons are 35. 1)when the ventilation system was not installed, The experimental results of the $CO_2$ concentration showed the average of 2,150ppm and the maximum of 2,740ppm in the classroom. This was the higher than 1,000ppm, the standard value of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development, 1000ppm. The $CO_2$ concentration was relatively increasing during school hours. 3)In case of the volume of ventilation of $800m^3$/h, the $CO_2$ concentration of classroom showed the average of 962 ppm and the maximum of 1,380 ppm. This was higher than 1,000ppm, the standard of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 4)The floating dust(PM10) was the maximum of 0.52 mg/$m^3$, the minimum of 0.25 mg/$m^3$, and the average of 0.32 mg/$m^3$ in case of the ventilation system off. Those were higher than the standard value 0.15 mg/$m^3$. In case of the ventilation system on, the floating dust(PM10) was the maximum of 0.174 mg/$m^3$ , the minimum of 0.048 mg/$m^3$, and the average of 0.078 mg/$m^3$. These were the lower than 0.15 mg/$m^3$, the standard of the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 5)The concentrations of $CO_2$ and PM10 were largely depending on the number of students and the ventilation system, The installation of the ventilation system is necessary for the amenity environment and the management of the indoor air quality.

  • PDF

인공환경 생육조건에서의 Amorphopallus paeoniifolius: Leaf Cycle (Amorphopallus Paeoniifolius in Greenhouse Environment: Leaf Cycle)

  • 안태현;고여빈;배준규;이정호;이기철
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2019년도 추계학술대회
    • /
    • pp.48-48
    • /
    • 2019
  • Amorphophallus paeoniifolius (Dennst.) Nicolson는 영명으로 Elephant yam 또는 Whitespot giant arum 으로 불리는 천남성과(Araceae) 식물로 동아시아, 뉴기니, 오세아니아, 마다가스카르 등지에서 자생하고 있으며 숲의 가장자리 또는 2차림에서 발견 된다. 다년생 식물로 덩이줄기는 어두운 갈색의 둥근모양으로 직경 20~25 cm로 자라고 수염뿌리가 사방으로 달린다. IUCN 적색목록(Red List)에 관심대상 종(LC: Least Concern)에 속하는 식물이다. 현지인들은 마(Dioscorea Polystachya Turcz.)처럼 채소로 먹기도 하며 약용으로 쓰이기도 하는데 복부장애, 소화불량, 천식, 기관지염, 빈혈 등에 약효가 있다. Amorphophallus paeoniifolius은 $25^{\circ}C{\sim}35^{\circ}C$, 연강수량 1,000~1,500 mm에서 잘 자란다. 가운데 눈이 올라오면서 생장을 시작하고 며칠이 지나서야 잎 또는 꽃으로 자라는지 알 수 있다. 잎의 생육주기는 잎눈이 생장을 시작하면 잎자루 끝에 소엽과 소잎자루가 접힌 채로 올라온다. 소엽들이 펴지면서 완전한 모습을 갖추는데 30일 이상의 생장기간을 갖는다. 잎의 형태는 우상복엽(pinnate compound leaf)으로 우산처럼 보이는 잎 하나로 광합성을 한다. 잎은 최대 높이 2.5~3 m, 너비 3 m까지 자라며, 잎자루의 색은 녹색과 청색으로 얼룩덜룩한 무늬가 있다. 인공환경 조건에서 Amorphophallus paeoniifolius 생활사 중 잎의 주기를 연구하기 위해서 광, 온도 등의 지상부 환경은 열대 및 아열대 식물의 자생지와 유사하게 조성하였고, 지하부 환경은 인공 배합토를 사용하여 조성하였다. 평균온도는 $25{\sim}28^{\circ}C$, 겨울철 최저 $16^{\circ}C$, 여름철 최고 $33^{\circ}C$를 유지 관리 하였다. 자동 환경제어시스템으로 온도 및 환기를 유지 관리하고 필요에 따라 수동제어 관리를 병행하여 조절하였다. Amorphophallus paeoniifolius는 잎을 먼저 생성하고 광합성으로 생산된 영양물질을 덩이뿌리에 저장을 하고 그 영양물질을 이용하여 꽃을 피우는 생육 특성을 지닌다. 실험에 사용된 공시 식물은 2018년 12월 미얀마에서 생체(덩이줄기) 형태로 도입되었다. 화분에 식재 후 약 5개월이 지난 시점에서 잎의 생장이 시작되었다. 2019년 7월 29일 기준으로 높이 80 cm, 너비 60 cm의 크기로 성장하였으며, 생육환경에 따라 3~5개월 뒤 잎이 지고 나면 다시 덩이줄기로 되돌아갈 것으로 판단된다. 하지만 지금까지 이 식물에 알려진 정보는 인공환경에서의 연구가 아닌 자연환경에서의 연구결과이기 때문에 인공적인 온실 환경에서 자란 Amorphophallus paeoniifolius는 잎의 주기는 더 오래 갈 수도 있으며 꽃의 주기 또한 느리거나 빠를 수 있다. 잎의 생장주기(Leaf Cycle)시 잎자루가 낮과 밤의 방향을 달리 하여 자라는 것이 관찰되었다. 이는 광합성을 위해서 잎자루의 방향을 햇빛 방향으로 돌리는 것으로 판단된다. Amorphophallus paeoniifolius를 실내 조경 식물 또는 식 약용의 소재식물로 활용하기 위해서는 꽃의 생장주기 등 추가적인 모니터링과 연구가 필요하다.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.