• Title/Summary/Keyword: 실내열교환기

Search Result 43, Processing Time 0.019 seconds

Study on Cement-based Grout for Closed-loop Vertical Grout Heat Exchanger (수직 밀폐형 지중열교환기 뒤채움재로서 시멘트 그라우트의 적용성 검토)

  • Park, Moon-Seo;Wi, Ji-Hae;Lee, Chul-Ho;Choi, Hang-Seok;Kang, Shin-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.107-115
    • /
    • 2010
  • In this paper, the applicability of cement grout bas been studied as an alternative to bentontite grout to backfill ground heat exchangers. To provide an optimal mixture design, the groutabilty and thermal conductivity of cement grouts with various mixture ratios were experimentally evaluated and compared. The unconfined compression strength of cement grout specimen was measured, which was exposed to cyclic temperature variation ranging from $50^{\circ}C$ to $-5^{\circ}C$. In addition, the integrity of the interface between circulating HDPE pipes and cement grout was evaluated by performing equivalent hydraulic conductivity tests, on the specimen. in which a pipe locates at the center of the specimen.

Evaluation of Thermal Response Test of Energy Pile (에너지 파일의 현장 열응답 시험에 관한 연구)

  • Yoon, Seok;Lee, Seung-Rae;Kim, Min-Jun;Go, Gyu-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.93-99
    • /
    • 2014
  • Use of geothermal energy has been increased for its economical application and environmentally friendly utilization. Particularly, for energy piles, a spiral coil type ground heat exchanger (GHE) is more preferred than line type GHEs such as U and W shaped GHEs. A PHC energy pile with spiral coil type GHE was installed in an area of partially saturated dredged soil deposit, and a thermal response test (TRT) was conducted for 240 hours under a continuous operation condition. Besides, remolded soil samples from different layers were collected in the field, and soil specimens were reconstructed according to the field ground condition. Non-steady state probe methods were conducted in the lab, and ground thermal conductivity and thermal diffusivity were measured for the different soil layers. An equivalent ground thermal conductivity was calculated from the lab test results and it was compared with the field TRT result. The difference was less than 5%, which advocates the use of an equivalent ground thermal conductivity for the multi-layered ground. Furthermore, this paper also represents an equivalent ground thermal diffusivity evaluation method which is another very important design parameter.

A Study on the Characteristics of Carbon Monoxide Intoxication of Gas Water Heater (가스온수기 일산화탄소 중독 특성에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.124-126
    • /
    • 2011
  • 본 연구에서는 가스온수기 사용 중에 발생하는 배기가스중의 일산화탄소 중독사고를 예방하기 위하여 사용자부주의, 설치불량 및 안전장치의 결함을 분석하고 문제점을 통해 사고예방대책을 강구하기 위한 것이다. 가스중독 사고 예방을 위해서는 목욕탕 또는 환기가 잘되지 아니하는 곳에 설치하지 않으며, 사용자는 창문 등으로 반드시 열어 사용하도록 한다. 열교환기 등의 부식이나 막힘 등에 대한 점검을 누락되지 않도록 하며, 전문 업체에 등록된 자가 시공하도록 한다. 안전 점검시 안전장치의 이상 유무 등을 점검한다. 즉, 가스온수기는 환기가 불량한 장소에 설치하는 경우 배기가스가 외부로 배출되지 못하고 실내에 체류하는 경우에 일산화탄소중독에 의한 사고로 이어지고 있기 때문에 예방대책에서 제시한 부분은 중독 사고를 예방하는데 기여할 수 있을 것으로 판단한다.

  • PDF

Experimental Analysis of Thermal Comfort of an Office Space for Different Supply Locations during Cooling (냉방시 사무실 공간의 급기 위치에 따른 실내 열환경 평가 실험)

  • 김명호;김요셉;김영일
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.115-120
    • /
    • 1999
  • 본 연구에서는 실제 조건과 유사하게 모사된 사무실 공간을 대상으로 냉방시 급기 위치에 따른 기온, 기류속도, 복사온도를 측정하여 열환경을 평가하였다. 사무실 공간은 실제의 조건과 유사하게 인체, 조명, 사무기기의 부하를 전기히터로 모사했으며, 외기부하는 벽체에 설치된 열교환기를 통과하는 부동액의 온도를 제어함으로써 모사하였다. 실험 결과 냉방 조건에서는 바닥급기 방식의 경우 평균온도가 천장급기에 비해 낮아 에너지 절약 측면에서 유리함을 알 수 있었다. 그러나 천장급기에 비해 수직온도차가 크고 급기구 근처에서는 수직온도차에 의한 불쾌감과 빠른 기류속도에 의한 드래프트의 위험이 있는 것으로 나타났다.

  • PDF

A Study on Emission Characteristics of Inserting CO Tube (CO튜브 삽입에 따른 오염 물질 배출특성에 관한 연구)

  • Lee, Jae-Park;Kim, Jong-Min;Lee, Seung-Ro;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.182-187
    • /
    • 2010
  • This study was the effect of inserting CO tube on $NO_x$ and CO emission characteristics in a compact combustion chamber. In detail, $NO_x$ and CO emission characteristics with changing of distance due to inserting CO tube between a burner and a main heat exchanger were investigated. For this study, the commercial program, FLUENT with GRI 2.11 detail reaction mechanism, was used for the numerical study and a commercial heat exchanger was tested for the experimental study. As results, when the CO tube was inserted between a burner and a main heat exchanger, it was verified that $NO_x$ and CO emissions was decreased simultaneously as CO tube was closed to a burner and the distance between CO tube and a main heat exchanger was increased.

A Study on Electronically Controlled R-134a Heat Pump System for a Fuel Cell Electric Vehicle (FCEV) (연료전지 자동차용 R-134a 전동식 히트펌프 시스템 개발에 관한 연구)

  • Lee, Jun-Kyoung;Lee, Dong-Hyuk;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.124-132
    • /
    • 2007
  • The main objective of this work is to investigate the characteristics of a heat pump system for fuel cell electric vehicle (FCEV). The present heat pump system adopts an electrically driven compressor running with R134a and uses the heat from the fuel cell stack as the heat source for the exterior heat exchanger. The experimental work has been done with various operating conditions such as different compressor speeds, fuel cell stack coolant temperatures and flow rates. The heating capacity was measured to be from 4 to 10 kW at $-20^{\circ}C$ ambient temperature, and the outlet temperature of interior heat exchanger was up to $70^{\circ}C$. After 30 seconds from start-up, the system reached a steady state and the heating capacity of 6.8 kW was acquired, and after 90 seconds, the air outlet temperature of interior heat exchanger became $35^{\circ}C$.

Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Prediction of Ground Thermal Properties from Thermal Response Test (현장 열응답 시험을 통한 지중 열물성 추정)

  • Yoon, Seok;Lee, Seung-Rae;Kim, Young-Sang;Kim, Geon-Young;Kim, Kyungsu
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.5-14
    • /
    • 2016
  • The use of geothermal energy has increased for economically and environmentally friendly utilization, and a geothermal heat pump (GSHP) system for space heating and cooling is being used widely. As ground thermal properties such as ground thermal conductivity and ground thermal diffusivity are substantial parameters in the design of geothermal heat pump system, ground thermal conductivity should be obtained from in-situ thermal response test (TRT). This paper presents an experimental study of ground thermal properties of U and 2U type ground heat exchangers (GHEs) measured by TRTs. The U and 2U type GHEs were installed in a partially saturated dredged soil deposit, and TRTs were conducted for 48 hours. A method to derive the thermal diffusivity as well as thermal conductivity was proposed from a non-linear regression analysis. In addition, remolded soil samples from different layers were collected from the field, and soil specimens were reconstructed according to the field ground condition. Then equivalent ground thermal conductivity and ground thermal diffusivity were calculated from the lab test results and they were compared with the in-situ TRT results.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.

발포금속의 현황과 장래 The Recently and future application of Metal Foams

  • Heo, Bo-Yeong;Jeong, Seung-Ryong;Kim, Byeong-Gu;Tak, Byeong-Su
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.17.1-17.1
    • /
    • 2009
  • 발포금속은 1948년에 Sosnik에 의해 알루미늄에 수은을 증발시키는 방법으로 발포 알루미늄을 제조한 이래, 1951년 Elliot에 의해 진보된 방식인 발포 매개체를 용탕에혼입하는 방법으로 발포금속을 제조하기 시작하였다. 현재 이들 선진국가의 생산방법 및 현황은 균질 기공의 조절, 연속주조 방식과 원가절감, 그리고 제조기술의 진보를 통하여 다양한 분야에 적용되고 있다. 그러나 실용화를 위해서는 요구특성을 만족하고 동시에 가격 경쟁력을 가진 제조기술의 보유 및 개발과 독특한 특성을활용한 새로운 적용 분야의 개척이 필요하다고 생각되며, 이를 위해 Harvard, MIT, Aachen, HMI 등 구미 유수 대학과 NASA, 미국방성등의 연구기관, ERG, 신강(新鋼) wire등 산업체를 중심으로제조 및 특성평가에 관한 기초연구와 활용방안이 활발히 모색중에 있다. 그리고 일부 자동차 생산 업체를중심으로 발포금속을 적용한 초경량, 에너지 절감형의 자동차 부품 소재,항공기 방열판 등에 대한 연구가 활발하게 진행되고 있다. 특히 금속 기체의 GASAR 공법은 Lotus 공법으로 Osaka 대학에서 개발되어 열교환기, 항공기, 방열기 등으로 응용이 확대되고 있다 국내에서 완제품생산은 실내장식용 복합패널로서 한소 프라임이 운영상의 문제로 생산을 중단하였으며, 유닉슨(주), 금강(주)에서 Batch식, 금성산업에서 Pot식이 일부 생산 및 연구가 진행되었으나 현재는 본연구실의 협조로 (주) 폼텍에서 발포패널을 주로 생산하고 있고 (주)드림메탈과 (주)아크로폼텍에서일부 생산되고, (주)동일알루미늄에서는 폐 scrap을 이용한 발포 Al 제조가 연구단계에 있다. 생기원에서는 분말 가열 흡음패널이 개발되었으나 강도와 내열성이 낮아 이들 특성을 향상시크는 연구가 진행중이다. 이들 제품은 성능상으로는 동양강판의 흡음패널과 KIMM의 필터용은연구개발이 낮은 수준이며, 본 연구팀과 공동 개발한 (주)폼텍의 복합패널은 10여 가지의 실용특허로 건축마감재로서 오히려 선진국수준을능가한 상태이다, 한편, 발포금속 기능성 개발은, 이들이 가지고 있는 우수한 특성 때문에 군수용으로부터 민수 산업용까지 전분야에 적용이 가능한 소재이므로 수요처를확장하고 있으므로 제품의 균질성, 안정성과 기능성 개발 향상을 위해 지속적이고 체계적인 연구가 필요하다고 생각된다.

  • PDF