• Title/Summary/Keyword: 실내분진

Search Result 45, Processing Time 0.02 seconds

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Experimental Study on Removal Characteristics of Indoor Suspended Particulates by Ventilation. (환기에 의한 실내 부유오염입자 제거특성에 관한 실험적 연구)

  • Kang, Tae-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.133-139
    • /
    • 2005
  • In this paper, the ventilation performance of suspended particulates in indoor side was investigated by step-down method. Experiments were performed in function of mechanical ventilation types and locations of supply and extract air. The type 2 ventilation system shows the highest removal characteristics rather than other 2 types. It means that the displacement ventilation has also good decay rates of concentration compared to mixing ventilation.

Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners (공기조화기용 열교환기의 공기측 파울링 입자 분석 연구)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.

An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance (30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구)

  • Noh, Ji-Hee;Park, Sang-Hyun;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.

Change of Volume of Isoflow in Pneumoconiosis Patients with Small Opacity (소음영 진폐증 환자에서의 등기류용량(Volume of Isoflow)의 변화)

  • Oh, Sang-Yong;Kim, Jee-Won;Jung, Chang-Young;Kim, Kyung-Ah;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.540-547
    • /
    • 1993
  • Backgrounds: The measurement of volume of isoflow has been considered as a sensitive test for detecting small airway diseases showing normal pulmonary function in a routine pulmonary function test. To evaluate the functions of small airway among dust exposed workers, the changes of volume of isoflow were measured and its applicability of managing early stage pneumoconiosis patients was studied. Method: The subjects were 67 male, pneumoconiosis with small opacity and FEV1>80%, FEV1/FVC>75% in spirometry and the controls were 20 male, no dust-exposed office workers. The maximal epiratory volume curves after inhalation of indoor air and $He-O_2$ gas mixtures were measured and ${\Delta}V_{max50},\;{\Delta}V_{max75},\;V_{iso}V/VC$ between the dust exposed and control workers were compaired. Results: 1) There were no significant differences between two group in ${\Delta}V_{max50}$ and ${\Delta}V_{max75}$. But the ratio of $V_{iso}V/VC$ of the subjects was siginificantly higher than that of the control (p<0.01). This study confirms that $V_{iso}V/VC$ is a very useful index in early detection of small airway dysfunction. 2) The ratio of $V_{iso}V/VC$ of the subjects was signigicantly different between only smoker group and mixed group(smoker and nonsmoker). It suggestes that smoking is an important cousative factor of small airway dysfunction. 3) As the profusion of the chest X-ray increased, the rartio of $V_{iso}V/VC$ increased, but no significant difference of $V_{iso}V/VC$ was found between categories of pneumoconiosis. The categories of pneumoconiosis and small airway dysfunction may not be related. 4) No significant relationship was established between the duration of work and the ratio of $V_{iso}V/VC$. Conclusions : It is concluded that the measurement of $V_{iso}V/VC$ is useful to detect small airway dysfuction of early stage pnuemoconiosis patents with small opacities but showing normal pulmonary function in a routine pulmonary function test.

  • PDF

A Study of Fine Dust Blocking Network Using Electrospinning Nanofiber Deposition (전기방사를 활용한 나노섬유 증착 미세먼지 방진망에 관한 연구)

  • Chan Young Lee;Sang Min Lee;Hyeon Jin Song;Jae Jun Lee;Young Soon Kim;Hong Gun Kim
    • Journal of The Korean Institute of Defense Technology
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 2024
  • While fine dust is currently spreading around the world, fine dust is so small that it easily enters indoors and deteriorates indoor air quality, so it is an essential issue that must be solved to maintain cleanliness and improve air quality in households. Research on nanoradiation technology is continuously being conducted to effectively block fine dust and secure air permeability and dust collection rate. In this study, a PVDF fine dust dust-proof net was manufactured through electrospinning, and an experiment was conducted to confirm the external environmental resistance and indoor air quality improvement efficiency of the manufactured dust-proof net. It was verified that this dustproof net can be a practical alternative to effectively block fine dust and prevent diseases caused by fine dust.

  • PDF

Indoor Air Quality Pollution of PM2.5 and Associated Trace Elements Affected by Environmental Tobacco Smoke (환경담배연기로 인한 실내공기 중 PM2.5 및 미량성분 오염 특성)

  • Lim, Jong-Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.317-324
    • /
    • 2014
  • Environmental tobacco smoke (ETS) samples were collected separately in mainstream and side-stream smoke using a self-designed smoking machine, and a total 40 of PM2.5 was collected with low volume air sampler at indoor environments with and without ETS in Daejeon, Korea. About 20 trace elements including toxic metals like As, Cr, Mn, Se, V, and Zn were determined in PM2.5 and ETS samples by instrumental neutron activation analysis (INAA). It is found that the emission factors of K, Cl, Na, and Al were much higher than those of toxic elements for both mainstream and side-stream smoke. The average concentration of PM2.5 was enriched by 1.5 times at smoking area ($58.7{\pm}18.1{\mu}g/m^3$) than at smoking free area ($38.6{\pm}12.7{\mu}g/m^3$). The concentration ratio of each element between smoking and smoking free area were ranged from 1.1 to 6.0 except Cu (1.0); especially, Ce (6.0), La (5.2), K (2.3), and Co (2.0) showed higher ratio, which suggests that the ETS is one of the possible increasing factors of PM2.5 and elemental concentration at indoor environment.

Improvement Effects of Soft Ground from Quick Lime Piles (생석회 말뚝에 의한 연약지반의 개량 효과)

  • Chun, Byung-Sik;Ko, Kab-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.1
    • /
    • pp.91-101
    • /
    • 2001
  • This paper investigates the effectiveness of quick lime piles for soft ground improvement. The field tests based on the results of the laboratory test were performed, and the results of field tests were compared with those of numerical analyses(FEM). The results of the field test showed that the domestic quick lime was very effective in reducing the water contents of the surrounding ground quickly due to its characteristics such as digestion, absorption, and exothermic reactions. Accordingly, consolidation occurred without any additional load increment and the shear strength of surrounding ground was increased more than twice. Therefore the quick lime pile method could be considered as an excellent improvement technique reducing the improvement period for soft ground. For the practical applications of the quick lime pile method, issues such as hydration heat, particulation and equipment enhancement should be solved through continuous research and development.

  • PDF

The Magnetic Field Simulation & Removal Characteristic of Nitrogen Oxide for Magnet Type Plasma Reactor (자석형 플라즈마 반응기의 자계 시뮬레이션과 질소산화물 제거 특성)

  • Lee, Hyun-Soo;Lee, Dong-Hoon;Park, Jae-Yoon;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.35-41
    • /
    • 2003
  • 산업의 고도화 및 도시의 집중화로 오염물질의 종류가 다양화 되었으며 여러 가지 오염물질 중에서도 비산 분진, 황산화물(SOx) 등은 연료 중의 특정성분을 제거하거나 연료를 대체하여 그 배출량을 줄일 수 있다. 그러나 질소산화물(NOx)의 경우에는 연료의 문제가 아니라 연소과정에서 반드시 발생되는 특징을 가진 오염물질이다. 이와 같이 환경오염물질의 제거기술에 있어 가장 중요하게 고려되어야 할 사항은 오염가스 제거의 효율성과 경제성이다. 따라서 본 연구에서는 사무실, 가정 등 주로 실내공기정화를 위하여 NOx 제거를 위한 선 대 평판형 플라즈마 반응기에 자석의 개수에 의한 자계세기 및 자속밀도 시뮬레이션과 도출된 시뮬레이션 결과를 바탕으로 제작된 반응기에 자석을 부가한 NOx 제거에 대한 실험을 하였다. 그 결과 자석을 부가한 경우가 NOx 제거효과에 있어 효율이 좋음을 알 수 있었다.

  • PDF

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Sheng, Nai-Li;Cheong, Seong-Ir;Lee, Jae-Keun;Park, Jong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1213-1219
    • /
    • 2008
  • This experimental study was to analyze thermal comfort and indoor air quality(IAQ) with ventilation and humidification in the classroom when system air conditioner was operated. The thermal comfort was estimated by the PMV index and the concentration of $CO_2$ and total suspended particle(TSP) were measured and compared with ventilation and humidification. As a result, the class room temperature distribution was $2{\sim}5^{\circ}C$ low during operating ventilation system and humidification. At 60% RH, PMV values of measuring points were ranged from +0.5 to -0.5 indicating optimal the range of thermal comfort. The average concentration of $CO_2$ gas and TSP were reduced 645 ppm, 0.17 mg/$m^3$ respectively, during operating the ventilation system. From the results, to maintain comfortable environment in the heated classroom, the ventilation and humidification were needed in winter season.

  • PDF