• Title/Summary/Keyword: 실내모형시험

Search Result 204, Processing Time 0.024 seconds

Analysis on the Behaviour of Foundation Using the Non-Linear Constitutive Laws (비선형구성식을 이용한 기초지반의 거동해석)

  • Jeong, Jin Seob
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.253-265
    • /
    • 1993
  • This paper presents a numerical method for implementing a nonlinear constitutive material model developed by Lade, into a finite element computer program. The techniques used are based on the displacement method for the solution of axial symmetric and plane strain nonlinear boundary value problems. Laboratory behaviour of Baekma river sand(#40-60) is used to illustrate the determination of the parameters and verification of the model. Computer procedure is developed to determine the material parameters for the nonlinear model from the raw laboratory test data. The model is verified by comparing its predictions with observed data used for the determination of the parameters and then with observed data not used for the determination. Three categories of tests are carried out in the back-prediction exercise; (1) A hydrostatic test including loading and unloading response, (2) Conventional triaxial drained compression tests at three different confining pressure and (3) A model strip footing test not including in the evaluation of material parameters. Pertinent observations are discussed based on the comparison of predicted response and experimental data.

  • PDF

Numerical analysis of deposition and channel change in the vegetation zone (식생대에서 유사의 퇴적과 하도변화 수치모의 분석)

  • Hwang, Hyo;Jang, Chang-Lae;Kang, Minseok
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.1
    • /
    • pp.23-34
    • /
    • 2023
  • This study analyzed the bed load transport and channel change on the vegetation zone through laboratory experiments and numerical simulations. To examine the effect of vegetation zone in the laboratory experiment, artificial vegetation zones made of acrylic sticks were installed in the experimental channel, and discharge conditions were adjusted to examine the bed load transport and channel change in the vegetation zone. Next, numerical simulations were performed by applying the same conditions as those of the laboratory experiment to the Nays2D model, a two-dimensional numerical model, and the applicability of the numerical model was examined by comparing the results with the results of the laboratory experiment. Finally, by applying a numerical model, the bed load transport and channel change according to the change in vegetation density were examined. As a result of examining the bed load transport and channel change in the vegetation zone according to the discharge condition change by applying the laboratory experiment and the numerical model, the results of the two application methods were similar. As the discharge increased, bed load from the upper stream was deposited inside the vegetation zone. On the other hand, on the other side of the vegetation zone, the flow was concentrated and erosion occurred. Also, the range of erosion increased in the downstream direction. As a result of examining the bed load transport and channel change according to the change in vegetation density, as the vegetation density increased, the bed load from the upper stream was deposited inside the vegetation zone. On the other hand, due to the increase in vegetation density, the flow was concentrated to the opposite side of the vegetation zone, erosion occurred.

Improvement Effects of Soft Clay Soils Using Quick Lime Piles (생석회 말뚝을 이용한 연약점토지반의 개량효과)

  • Kim, Younghun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.5
    • /
    • pp.45-51
    • /
    • 2010
  • This study is to evaluate an application of technology to the soft ground stability using quick lime pile in the field. We investigated properties of Korean quick lime by conducting loading test and theoretical consideration about a principle and property of soft ground improvement by quicklime. According to the test results, it was estimated that quick lime pile method has dehydration effect by absorption of quick lime, consolidation effect by swelling of pile, increasing bearing by strength of pile itself and decreasing sinking effect, etc. A material property of quick lime is favorable for construction and considerable strength. In the case of higher strength is required, using cement as additive would increase material strength.

Analysis of ground behavior for model tunnel excavation with pipe roof reinforcement using close range photogrammetric technique (근거리 사진계측기법을 이용한 강관보강 모형터널굴착의 지반거동 분석)

  • Lee, Jung-Hwan;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.387-402
    • /
    • 2014
  • In congested urban areas, constructions of tunnel structures have became necessary due to a lack of surface space. The excavation of any tunnel generated the ground disturbances of surrounding ground and displacements is major concern. Therefore, a study of tunnel stability is necessary. In this study, the authors have investigated the stability and failure pattern of tunnel through the model tunnel test. In this study, the close range photogrammetry was used to measure the ground deformation. The measured data was converted to displacement vectors and contours. And then it compared to FE analysis and empirical formula. In addition, this study presented the comparison between steel pipe reinforced model tunnel and unreinforced model tunnel. The ground deformation for both the steel pipe reinforced model tunnel and the unreinforced model tunnel was analysed.

Analysis of Permeation Efficiency in Soil for OPC and Non-Pollution MIS Grouts by Laboratory Model Test (실내모형시험을 통한 OPC와 친환경 MIS 그라우트의 지반 침투성능 분석)

  • Ahn, Jung-Ho;Lim, Heui-Dae;Choi, Dong-Nam;Song, Young-Su
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.307-315
    • /
    • 2012
  • In this paper, a laboratory model test was conducted to evaluate grouting efficiency of ordinary portland cement(OPC) and micro cement used in MIS(Micro-Injection Process System). For this research, a injection equipment was developed for pressure permeation which can evenly simulate various grouting tests in a laboratory and suggested a standard for the production of the test specimen. Using the injection device, the laboratory injection tests of grouts were prepared with water/cement ratio of 1:1, 2:1, 3:1, 4:1, and 5:1. The analysis of injection test for pressure permeation showed that the efficiency of injection increases linearly as the water/cement ratio increases. Comparison of efficiency of the injection indicates that MIS with a relatively smaller average diameter shows more efficient injection than the OPC. In the low ratio of water/cement as 2:1~1:1, the injection efficiency of OPC was especially poor. Also, a nonlinear grout volume-injection time is represented by a hyperbolic model and grout volume predicted by hyperbolic model was compared with the value measured. From the comparison, it shows that the hyperbolic model has the potential of evaluating the efficiency of grouting.

Material Characteristics and Field Tests of FRP Reinforcing Members (FRP 보강재의 역학적 특성 및 현장시험 결과분석)

  • 석정우;김장용;김명모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10b
    • /
    • pp.31-42
    • /
    • 2001
  • 다양한 방식으로 제작된 유리섬유 강화 플라스틱관(FRP pipe)의 인장 및 휨강도 시험 결과로부터 제작방식에 따른 FRP관의 강도 특성을 비교 검토하였다. 또한, 사면보강대책으로서 FRP 그라우팅 공법의 현장 적용성을 평가하기 위하여, FRP 그라우팅에 따른 지반강도의 증진효과 및 보강재의 인발저항력을 산정하였다. 이를 위하여, 지반의 상대밀도 및 구속압에 따른 보강재 인발저항력의 변화 및 압력주입에 의한 확공효과 평가를 위하여 실내모형실험이 이루어졌다. 또한, FRP 그라우팅이 시공된 현장에서 공내재하시험, 투수시험, 그리고 시추공전단시험 등을 실시하여 FRP 그라우팅에 의한 지반보강 효과 및 차수효과를 정량적으로 산정하였다.

  • PDF

Development of Miniature Cone and Characteristics of Cone Tip Resistance in Centrifuge Model Tests (원심모형실험용 소형 콘 개발 및 콘 선단저항치 특성에 관한 연구)

  • Kim, Jae Hyun;Kim, Dong Joon;Kim, Dong Soo;Choo, Yun Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.631-642
    • /
    • 2013
  • The standard CPT(Cone Penetration Test), which can be easily performed to investigate in-situ soil engineering properties, has been widely used. CPT are also widely being utilized in centrifuge model tests. In this study, a miniature cone with 10mm diameter was developed and its applicability in the centrifuge was evaluated. The developed miniature cone was equipped with a four degree-of-freedom in-flight robot. A series of cone penetration tests was performed under four centrifuge acceleration levels. As results, the cone resistances measured at the same confining stress within shallow penetration depth were affected by the centrifugal accelerations. The critical depth was proportional to the cone diameter and relative density. Cone resistances results below the critical depth and soil parameters obtained from the laboratory tests were compared with those by previously proposed empirical relations.

Study of the Influence of Mandrels on the Smear Zone and the Variation of Permeability (스미어존 형성과 투수성 변화에 미치는 멘드럴의 영향에 관한 연구)

  • Kim, Su-Sam;Jang, Yeon-Su;Go, Gyeong-Hwan
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.45-58
    • /
    • 1997
  • In this paper the factors developing ground disturbance with the penetration of PDB mandrels are analysed by using field reconnaissance and laboratory test. In the laboratory tests, the amount of smear zones around the PDB mandrels is compared with respect to the shape and the size of mandrels by penetrating model mandrels of various shapes into the reconstituted clay. The shapes of mandrels selected are circular, oval and rectangular. It was recognized from the field reconnaissance that the size and shape, driving techniques of mandrels, as well as the size and shape of anchor shoe could develop ground disturbance. The mandrels that would reduce the smear effect of clay is oval and rectangular shapes rat her than circular one. It was found that the smear effect becomes smaller as the ratio of the long and short edge of the rectangular shape mandrel becomes larger.

  • PDF

Reduction of Horizontal Earth Pressure on Retaining Structures by a Synthetic Compressible Inclusion (압축성재료를 이용한 콘크리트 옹벽의 수평토압 저감방안에 대한 연구)

  • Yoo, Ki-Cheong;Paik, Young-Shik;Kim, Ho-Bi;Kim, Khi-Woong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.1
    • /
    • pp.19-28
    • /
    • 2003
  • Current methods for lateral thrust calculations are based on the classical formulations of Rankine or Coulomb. However, the previous studies indicate that lateral earth pressures acting on the wall stem, which is the function of deformation parameters of the backfill, are close to the active condition only in the top half of the wall stem and in the lower half of the wall stem, the lateral earth pressures are significantly in excess of the active pressures. This paper presents the compressible inclusion function of EPS which can results in reduction of static earth pressure by accomodating the movement of retained soil. A series of model tests were conducted to evaluate the reduction of static earth pressure using EPS inclusion and determine the optimum stiffness of EPS. Also, field test was conducted to evaluate the reduction of static earth pressure using EPS inclusion. Based on field test it is found that the magnitude of static earth pressure can be reduced about 20% compared with classical active earth pressure.

  • PDF

Improvement Effects of Soft Ground by Granular Pile (Granular Pile에 의한 연약지반의 개량효과)

  • 천병식;김백영
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.43-54
    • /
    • 2002
  • As construction cases of structure are increasing in the soft ground, the necessity of ground improvement is also increasing. Granular pile is one of the improvement methods for soft ground and for loose sandy soil. In domestic, SCP(Sand Compaction Pile) method using sand material has been mainly used to improve soft ground, but Granular pile with crushed-stone was not used much. However, alternative material such as crushed-stone is needed to substitute for sand due to the environmental and economical problems. In this study, staged load test and consolidation test were performed in the laboratory to observe the behavior of soft ground improved by Granular pile. In order to evaluate the characteristics such as bearing capacity, drainage, md settlement, sand and crushed-stone were applied as each pile material. The test results show that crushed-stone has higher bearing capacity and less settlement than those of sand under similar fore water pressure condition. Therefore, crushed-stone is determined to be appropriate as the substitute for sand.