• Title/Summary/Keyword: 실내공기 질

Search Result 242, Processing Time 0.039 seconds

A Study on the Seasonal Survey of the Indoor Air Quality in New Apartment Houses (신축 공동주택의 계절별 실내공기질 실측조사에 관한 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Hwang, Gi-Huen
    • Land and Housing Review
    • /
    • v.4 no.4
    • /
    • pp.417-424
    • /
    • 2013
  • The purpose of this study was to investigate the characteristics of the indoor air quality by season. The surveyed houses were 48 new apartment complex in 2012 across the country. The houses were carried out the bakeout before the test. The measuring method was "Indoor air quality testing standards process" and the measured items were formaldehyde, benzene, toluene, ethylbenzene, xylene, styrene average emissions. All the items were more emitting during the summer. From June to September the average concentration of formaldehyde emission was higher than other seasons. The average emissions of benzene concentrations in all seasons were released in small quantities. Average emissions of toluene and ethylbenzene concentration from April to August showed slightly higher emissions. Xylene and styrene concentration showed the highest emissions at April, but without large deviations throughout the year.

Efficacy and Safety Evaluation of an Air Sterilizer Equipped With an Electrolytic Salt Catalyst for the Removal of Indoor Microbial Pollutants (염촉매 전기분해 공기살균기의 효능 평가)

  • Sun Nyoung Yu;Ho-Yeon Jeon;Bu Kyung Kim;Ae-Li Kim;Kyung Il Jung;Gye Rok Jeon;Soon Cheol Ahn
    • Journal of Life Science
    • /
    • v.34 no.7
    • /
    • pp.500-508
    • /
    • 2024
  • Recently, there has been increasing interest in enhancing the indoor air quality, particularly in response to the growing utilization of public facilities. The focus of this study was on assessing the efficacy and safety of an air sterilizer equipped with electrolytic salt catalysts. To that end, we evaluated the antimicrobial activity of the vapor spraying from the air sterilizer and its cytotoxicity in condensed form on human cell lines (HaCaT, BEAS-2B, and THP-1). Against the test organisms, which comprised five bacterial strains (Staphylococcus aureus, Bacillus subtilis, Escherichia coli, Pseudomonas aeruginosa, Salmonella typhimurium) and one fungal strain (Candida albicans), the air sterilizer exhibited relatively high antimicrobial activities ranging from 10.89 to 73.98% following 1 and 3 hr of vapor spraying, which were notably time-dependent. Importantly, cytotoxicity assessments on human cells indicated no significant harmful effect even at a 1.0% concentration. Comprehensive safety evaluations included morphological observations, gene expression (Bcl-2, Bax) tests, and FACS analysis of intracellular ROS levels. Consistent with previous cytotoxicity findings, these estimates demonstrated no significant changes, highlighting the air sterilizer's safety and antimicrobial activities. In a simulated 20-hr operation within an indoor environment, the air sterilizer not only showed an 89.4% removal of total bacteria but also a 100.0% removal of Escherichia sp. and fungi. This research outlines the potential of the developed electrolytic salt catalyst air sterilizer to effectively remove indoor microbial pollutants without compromising human safety, underscoring the solution that it offers for improving indoor air quality.

Evaluation of Decreasing Concentration of Radon Gas for Indoor Air Quality with Magnesium Oxide Board using Anthracite (안트라사이트를 활용한 산화마그네슘 보드의 실내 공기질 중 라돈가스 농도 저감 평가)

  • Pyeon, Su-Jeong;Lim, Hyun-Ung;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • Radon gas, which is present on the earth, is a primary carcinogen released from rocks, soil, building materials, etc., and exists as a unique gas phase. In order to solve the risk of radon gas, we evaluated the basic performance which can be used as indoor finishing materials in addition to the radon gas reduction properties of the matrix using anthracite. An anthracite used as a conventional filter material was used to produce a matrix, and a test was conducted to replace the gypsum board, which is one of the building materials used in the existing room. As the anthracite replacement ratio increases, flexural failure load strength increases and thermal conductivity tends to decrease. Depending on the thickness of the board, the reduction performance of radon gas shows a slight difference.

Stabilization of Soil Moisture and Improvement of Indoor Air Quality by a Plant-Biofilter Integration System (식물-바이오필터에 의한 토양수분 안정화 및 실내 공기질 향상)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.751-762
    • /
    • 2015
  • This study was performed to investigate the stability of soil moisture in controlling air ventilation rate within a horizontal biofilter, and to compare removal efficiency (RE) of indoor air pollutants including fine dust, volatile organic compounds (VOCs), and formaldehyde (HCHO), depending on whether dieffenbachias (Diffenbachia amoena) were planted in the biofilter. The relative humidity, air temperature, and soil moisture contents showed stable values, regardless of the presence of D. amoena, and the plants grew normally in the biofilter. REs for number of fine dust particles (PM10 and PM2.5) within the biofilter filled with only soil were at least 30% and 2%, respectively. REs for number of fine dust particles (PM10 and PM2.5) within the biofilter including the plants were above 40% and 4%, respectively. RE for fine dust (PM10) weight was above 4% and 20%, respectively, in the biofilter containing only soil or soil together with plants. In the case of the biofilter filled with only soil, REs for xylene, ethylbenzene, toluene or total VOC (T-VOC) were each more than 63%; however, REs for benzene and formaldehyde (HCHO) were above 22% and 38%, respectively. In the biofilter with the plants, REs for xylene, ethylbenzene, toluene, and T-VOC were each above 72%, and REs for benzene and HCHO were above 39%. Thus, RE of the biofilter integrated with plants was found to be higher for volatile organic compounds than for fine dust. Hence, the biofilter was very effective for indoor air quality improvement and the effect was higher when integrated with plants.

A study on the finishing materials for Reduction of Indoor pollution (실내 환경오염 감소를 위한 건축마감 재료에 관한 연구)

  • Kim, Ja-Kyung;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.303-313
    • /
    • 2007
  • Nowadays, according to many studies, indoor space's pollution level is two to ten times higher than outdoor space's. This result arouses our attention. The major causes of deterioration of indoor air quality are the lack of ventilation caused by draught-proofing and insulation construction, and harmful chemical substances emitted from building materials, office machine and furniture. Therefore, we are continuing research to find the method for healthful house and production of many forms of well-being goods. However, because of exaggerated advertisements and the lack of accurate information, consumers choose the products whose performance is not verified. Therefore, this study investigates the actual conditions of pollution by building materials and the extent of the health damage by this pollution, and suggests the method for minimizing indoor pollution in aspect of indoor environment control and the use of environment friendly materials. But the building materials presented in this study are limited to the environment friendly construction materials that are in circulation In domestic market because this research is primarily aimed to give domestic consumers the standard for selecting this materials.

소통+섬기는 마음 - 우리 사업장 탐방 - 편안한 청사, 쾌적한 청사, 즐거운 청사 행복한 삶의 질을 고민하고, 변화하는 정부청사관리소

  • Choe, Yong-Gyun
    • 건강소식
    • /
    • v.34 no.9
    • /
    • pp.40-41
    • /
    • 2010
  • 정부청사를 한 번 이라도 찾아본 사람들은 느꼈을 것이다. 철저한 보안 속에 친절함과 배려가 느껴지고, 수많은 민원인으로 혼잡한 가운데에서도 쾌적함과 편안함이 느껴진다. 자칫 딱딱하게 보일 수 있는 정부청사에서 느껴지는 이 섬세함은 바로 정부청사관리소에 의한 것이라고 해도 과언이 아니다. 일반인에게 잘 알려지지 않은 정부청사관리소, 실내 공기를 정화하고 마음도 시원하게 만들어주는 그윽한 허브 향기처럼, 정부청사를 쾌적하고 행복한 곳으로 만들기 위해 한걸음씩 변화해 나가고 있는 행정안전부 정부청사관리소에 대해서 알아본다.

  • PDF

Distruction of Benzene by Using UV/$TiO_2$ Photocatalyst (자외선과 이산화티타늄계 광촉매를 이용한 벤젠의 분해)

  • 전의찬;송민종;사재환;노기완;박찬웅
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.366-368
    • /
    • 2000
  • 휘발성유기화합물질(Volatile Organic Compound ; VOCs)은 오존등 광화학옥시단트로 인한 대도시의 대기질 악화와 함께 도시환경에서 중요한 발암성 물질이거나 만성 또는 급성의 건강장해를 일으킴으로써 공중보건상에 나쁜 영향을 주는 것으로 조사되고 있다. 특히 실내 공기중의 VOCs는 건축자재, 가구, 접착제, 카페트, 흡연 및 취사행위 및 난방을 포함한 연료의 연소 등 다양한 오염원으로부터 방출되는 건으로 알려져 있다. (중략)

  • PDF

Experimental Investigation on the Performance of Small-Sized Dehumidification Rotor for Residential Use (가정용 소형 제습로터의 성능에 대한 실험적 연구)

  • Han, Ji-Chao;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2344-2349
    • /
    • 2015
  • In Korea, summer is hot and humid, and air-conditioners consume too much electricity due to large amount of latent heat. Simultaneous usage of dehumidifier may reduce the latent heat and save the electricity. In this study, dehumidification performance was measured in a constant temperature and humidity chamber for a small-sized dehumdification rotor made of inorganic fiber impregnated with metallic silicate. Variables were rotor speed, room temperature, regeneration temperature, room relative humidity and frontal velocity to the rotor. Results showed that there existed optimum rotor speed (1.0 rpm), and optimum regeneration temperature ($100^{\circ}C$). Above the optimum rotor speed, incomplete regeneration is responsible for reduced dehumidification. Above the optimum regeneration temperature, increased temperature difference between regeneration and dehumidification process is responsible for reduced dehumidification. The amount of dehumidification also increases with the increase of relative humidity, dehumidification temperature and flow velocity into the rotor.