• Title/Summary/Keyword: 실내공기유동

Search Result 77, Processing Time 0.023 seconds

Uncertainty Analysis of a Pharmacokinetic Modeling for Inhalation Exposure of Benzene from the Use of Groundwater at Dwelling (거주지의 지하수사용에서 유래한 벤젠의 흡입노출에 대한 동적약리학 모델의 불확실성 분석)

  • 김상준;이현호;박지연;이유진;유동한;양지원
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.28-38
    • /
    • 2004
  • This study presents the result of uncertainty and sensitivity analysis of a pharmacokinetic model which describes the distribution and removal of benzene at each organ when an indivisual inhales indoor contaminated air with benzene originated from groundwater. The pharmacokinetic model simulates the distribution of benzene deposited in organs of human body through inhalation of contaminated indoor air as well as degradation-metabolism in liver. This study focused on the uncertainty problem induced from the use of the single values for blood flow, partition coefficient, degradation constant, volume, etc. of each organ which was due to a lack of knowledge about these parameters or their measurements. To solve this problem, uncertainty analysis on the pharmacokinetic model was conducted simultaneously which would help understanding the risk assessment associated with VOCs.

A study of flow characterisitics in a clean room with work table (작업대가 있는 청정실내의 유동특성에 관한 연구)

  • 이재헌;이진원;이상렬
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.852-860
    • /
    • 1986
  • The effect of placing a worktable in a vertical laminar flow clean room is invesgiated by a numerical simulation. The model clean room is assumed to be a rectangular square of 2m*2m, in which a worktable of 0.8m long and 0.1m thick is located at 0.7m above the floor. Major parameters are the horizontal position of the table and the inlet flow velocity. The flow is assumed to be laminar throughout the clean room. Navier-Stokes equations with the pressure terms are directly solved by the SIMPLE algorithm. Boundary conditions at the two exits are given in terms of pressure conditions. The flow pattern, pressure loss due to viscous friction, the ratio of flow rates through each exit and pressure imbalance at the exits are calculated. All of the flow characteristics are seen to vary substantially with the location of the table, but are quite insensitive to the inlet flow velocity(Reynolds number). As an example, the flow rate through each exit can very by as much as 30% depending on the location of the table.

A study on the Characteristics of a Centrifugal Fan Vibration and Noise (Centrifugal Fan 송풍기의 진동.소음 특성에 관한 연구)

  • 김태형;김옥현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.999-1003
    • /
    • 1992
  • Because of low noise and small size with huge capacity, a centrifugal fan is widely used for ventilation, air-conditioner and so on, which are very near to human life. Because of the complexity of its vibration and noise generation mechanics, most of researches on them are based on experimental methods. This study is to characterize the centrifugal fan noise and vibration. It is considered that noise is composed of the structural vibration noise and the air flow induced aerodynamic noise. To decouple the structural vibration noise the centrifugal fan is masked with an adhesive tape, such that air blowing is prohibited thus only the structural vibration noise is extracted. The noise level and characteristics in the frequency domain are verified and compared with those of total mixed one. This study shows some significant results that the structural vibration noise has relatively narrow band power spectrum compared with the total mixed one and has a strong periodicity. The sound level is lowered about 5dB by the removal of air flow with the masked fan for an air-conditioner used in this study.

A Study on the Air Ventilation System of Operation Room for the Prevention of Hospital Infection (수술중 감염방지를 위한 공조시스템의 개선방안에 대한 연구)

  • Kim Chun-Sook;Kwon Soonjung;Joo Youngcheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.552-557
    • /
    • 2004
  • The air ventilation system of operation rooms has been studied for the prevention of cross infection during the operation. Operation rooms and air ventilation systems of three University hospitals are investigated. The distribution of microbe is measured by cultivating air samples in the operation room. A two-dimensional model for the cross-section of an operation room is developed for the CFD analysis. The characteristics of air flow in operation room are calculated by using a CFD program. The current air ventilation system of an old hospital does not deliver the clean air to the operation area efficiently. A new air ventilation method which improves air venting with little increase of the cost of equipment is suggested.

  • PDF

Convergence Evaluation of Indoor Air Measurement in Medical Institution (의료기관 실내공기 측정의 융합적 평가)

  • Lee, Yu-Hee;Choi, Yu-Jin;Choi, Jung-OK
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • The purpose of this study was to investigate the indoor air quality of medical institutions and to present the detailed management plan by analyzing the actual situation of management and analyzing the difference according to the place in a convergent. ($PM_{10}$), carbon dioxide ($CO_2$), formaldehyde (HCHO), total aerobic bacteria (TAB) and carbon monoxide (CO) were investigated in 153 hospitals in Busan. As a result, The overall output average did not exceed the maintenance criteria, but the maximum values for each item were 91% for $PM_{10}$, 97% for $CO_2$, 96% for HCHO, and 99% for bioaesol. And It is confirmed that this is very close to the standard. In addition, the results of each place showed different values according to each feature, but there was no significant difference in the results of five measurements. In conclusion, Indoor air in medical institution considering the characteristics should be performed systematic and detailed management of ventilation facilities and energy problems.

Microbial Differentiation and its Biochemical Bases (미생물의 분화와 그 생화학적 기구)

  • 김종협
    • Korean Journal of Microbiology
    • /
    • v.11 no.2
    • /
    • pp.101-106
    • /
    • 1973
  • The microwave of 2450 MHz, generated by a household cooking oven, was evaluated for its applicability to melt various rehydrated media and to remove dissolved oxygen from tubed media for anaerobic culture. The effect on the sterilization of E. coli in selective media was also evaluated. The following results were obtained. 10 The microwave oven was useful in saving time for melting media and in eliminating heat and combustion gas from the laboratory, which were inevitable by-products in the conventional flame method. 2) Dissolved oxygen could be removed without boiling over by exposing the tubes of anaerobic culture medium after putting them in a wire basket in a beaker with water. 30 The count of E. coli during the melting of MacConkey and EMB agar were similar to those treated with open flame. The microwave treatment was not considered a possible mean to replace autoclaving even in these selective media.

  • PDF

A Realistic Human Exposure Assessment of Indoor Radon released from Groundwater (지하수로부터 방출된 라돈에 의한 현실적인 체내축적량 평가)

  • Yu, Dong-Han;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.121-126
    • /
    • 2002
  • The work presents a realistic human exposure assessment of indoor radon released from groundwater in a house. At first, a two-compartment model is developed to describe the generation and transfer of radon in indoor air from groundwater. The model is used to estimate radon concentrations profile of indoor air in a house us]ng by showering, washing clothes, and flushing toilets. Then, the study performs an uncertainty analysis of model input parameters to quantify the uncertainty in radon concentration profile. In order to estimate a daily internal dose of a specific tissue group in an adult through the inhalation of such indoor radon, 3 PBPK(Physiologically-Based Pharmaco-Kinetic) model is developed. Combining indoor radon profile and PBPK model is used to a realistic human assessment for such exposure. The results obtained from this study would be used to the evaluation of human risk by inhalation associated with the indoor radon released from groundwater.

Measurement of Air Motion in a Diesel Engine Combustion Chamber using Hot Wire Anemometer (열선유속계에 의한 디이젤기관 연소실내의 공기유동 측정)

  • U, Dae-Seong;Go, Dae-Gwon;An, Su-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.86-94
    • /
    • 1987
  • In order to examine the flow motion in a combustion chamber of a motored diesel engine, the variation of instantaneous are velocity at a fixed point in combustion chamber was measured by the constant temperature hot wire anemometer, varing engine speed, shroud shape and shroud position. The results are summerized as follows: 1. The variation of air velocity in a combustion chamber is closely related with the valve timing and piston velocity. 2. The air velocity in the cylinder at suction stroke is being increased and maximized at 60$^{\circ}$ ABDC in compression stroke and then decreased at the e.v.o. in expansion stroke. 3. The mean velocity using shroud valve was less than no shroud valve. However the turbulent intensity using shroud valve was larger than no shroud valve. 4. The turbulent intensity with 90$^{\circ}$shroud valve was larger than that of 120$^{\circ}$shroud valve, and 90$^{\circ}$shroud valve at 180$^{\circ}$shroud position had the largest turbulent intensity.

  • PDF

Measurement of Air Motion in a Diesel Engine Combustion Chamber using Hot Wire Anemometer (열선유속계에 의한 디이젤기관 연소실내의 공기유동 측정)

  • Dae-Sung Woo;Dae-Kwon Ko;Soo-Kil Ahn
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.40-40
    • /
    • 1987
  • In order to examine the flow motion in a combustion chamber of a motored diesel engine, the variation of instantaneous are velocity at a fixed point in combustion chamber was measured by the constant temperature hot wire anemometer, varing engine speed, shroud shape and shroud position. The results are summerized as follows: 1. The variation of air velocity in a combustion chamber is closely related with the valve timing and piston velocity. 2. The air velocity in the cylinder at suction stroke is being increased and maximized at 60° ABDC in compression stroke and then decreased at the e.v.o. in expansion stroke. 3. The mean velocity using shroud valve was less than no shroud valve. However the turbulent intensity using shroud valve was larger than no shroud valve. 4. The turbulent intensity with 90°shroud valve was larger than that of 120°shroud valve, and 90°shroud valve at 180°shroud position had the largest turbulent intensity.

Optimization for the Humidification Performance of a Residential Rotor-Type Humidifying Element (가정용 로터식 가습 소자의 가습 성능 최적화)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.7-13
    • /
    • 2017
  • A comfortable indoor environment is important considering that many hours are spent in residential or office space. A humidifier is used to control the indoor humidity. In particular, an element type humidifier has the advantage of a simple structure and low energy consumption. Two types of humidifiers - stationary or rotor - are commonly used for residential purposes. In this study, performance optimization was conducted for a rotor-type humidifying element used in a residential humidifier. The optimization included the rotation speed, water submersion depth, etc. The test range consisted of an open area to the air from 57 to 90%, rotation speed from 0.2 to 2.0 rpm, frontal air velocity from 0.5 to 2.5 m/s. The results showed that the optimal open area to air was 70%. On the other hand, the effects of the rotation speed on the moisture transfer rate was negligible. On the other hand, the pressure drop increased with increasing rotation speed. As the frontal air velocity increased, both the moisture transfer rate and pressure drop increased. The humidification capacity of the present element was 0.08 ~ 0.31 kg/hr. A comparison of the data with the theoretical results was made.