Convergence Evaluation of Indoor Air Measurement in Medical Institution

의료기관 실내공기 측정의 융합적 평가

  • Lee, Yu-Hee (Division of public health, Graduate school of Inje University) ;
  • Choi, Yu-Jin (Department of Dental Hygiene, Youngsan University) ;
  • Choi, Jung-OK (Department of Dental Hygiene, Youngsan University)
  • 이유희 (인제대학교 일반대학원 보건학과) ;
  • 최유진 (영산대학교 치위생학과) ;
  • 최정옥 (영산대학교 치위생학과)
  • Received : 2016.11.08
  • Accepted : 2017.01.20
  • Published : 2017.01.28

Abstract

The purpose of this study was to investigate the indoor air quality of medical institutions and to present the detailed management plan by analyzing the actual situation of management and analyzing the difference according to the place in a convergent. ($PM_{10}$), carbon dioxide ($CO_2$), formaldehyde (HCHO), total aerobic bacteria (TAB) and carbon monoxide (CO) were investigated in 153 hospitals in Busan. As a result, The overall output average did not exceed the maintenance criteria, but the maximum values for each item were 91% for $PM_{10}$, 97% for $CO_2$, 96% for HCHO, and 99% for bioaesol. And It is confirmed that this is very close to the standard. In addition, the results of each place showed different values according to each feature, but there was no significant difference in the results of five measurements. In conclusion, Indoor air in medical institution considering the characteristics should be performed systematic and detailed management of ventilation facilities and energy problems.

본 연구는 다중이용시설등의 실내공기질 관리법에 의해 시행되고 있는 의료기관의 실내공기질을 조사하여 관리실태를 파악하고 장소에 따라 나타나는 차이를 융합적으로 분석하여 세부적 관리방안을 제시하기 위한 목적으로 실시하였다. 부산광역시에 소재하는 의료기관 153개를 대상으로 직접 방문조사하여 미세먼지($PM_{10}$), 이산화탄소($CO_2$), 포름알데하이드(HCHO), 총부유세균(TAB), 일산화탄소(CO)를 조사하였다. 연구결과를 살펴보면, 전체적 산출평균은 유지기준을 초과하지 않았으나, 항목별 최대값은 $PM_{10}$이 91%, $CO_2$가 97%, HCHO가 96%, TAB가 99%에 해당하여 기준에 매우 근접하는 것을 확인하였다. 또한, 유동인구와 관련하여 측정 장소를 다르게 하여 측정한 결과는 각 특징에 따라 서로 다른 값을 보였다. $PM_{10}$은 로비에서 $61.80{\pm}9.66{\mu}g/m^2$, $CO_2$는 복도에서 $632.08{\pm}112.86ppm$으로 가장 높게 나타났다. 반면, HCHO는 입원실이 $21.88{\pm}17.03{\mu}g/m^2$으로 가장 높은 것으로 나타났다. TAB와 CO는 복도에서 각각 $634.08{\pm}46.41 CFU/m^2$$0.81{\pm}0.66ppm$으로 가장 높았다. 5곳의 측정결과 유의한 차이는 없었다. 결과적으로 의료기관 실내공기는 불특정 다수인들이 수시로 출입가능하며 환자들이 주로 생활하는 시설적 특징을 충분히 고려하여 보다 세밀하고 체계적인 관리가 이루어져야 한다.

Keywords

References

  1. L. D. Montoya, L. M. Hildemann, "Evolution of the Mass Distribution of Resuspended Cat Allergen(Fel d1) Indoors following a Disturbance", Atmospheric Environment, Vol. 35. No. 5, pp. 859-866, 2001. https://doi.org/10.1016/S1352-2310(00)00379-4
  2. Y. S. Kim, E. G. Lee, M. J. Yup, K. Y. Kim, "Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings", Kor. J. Env. Hlth. Soc., Vol. 28, No. 1, pp. 89-92, 2002.
  3. W. H. Yang, K. Y. Park, K. H. Park, C. S. Yoon, B. S. Son, J. M. Jeon, H. S. Lee, W. H. Choi, S. D. Yu, J. S. Han, "Microenvironmental Time Activity Patterns of Weekday and Weekend on Korean", Journal of Korean Society for Indoor Environment, Vol. 6, No. 4, pp. 267-274, 2009.
  4. C. Chen, B. Zhao, "Review of Relationship between Indoor and Outdoor partivles: I/O Ratio, Infiltration Factor and Penetration Factor". Atmospheric Environment, Vol. 45, No. 2, pp. 275-288, 2011. https://doi.org/10.1016/j.atmosenv.2010.09.048
  5. Y. H. Chung, J. B. Hong, Y. H. Chang, "A Study on the Microbial Air Pollution of Urban Living and Indoor Environment", Kor. J. Env. Hlth. Soc., Vol. 27, No. 2, pp. 1-9, 2001.
  6. S. M. Kim, H. J. Kim, "Comparison of Formaldehyde Emission from Building Finishing Material at Various Temperature in under Heating System; ONDOL", Indoor Air, Vol. 15, No. 5, pp. 317-325, 2005. https://doi.org/10.1111/j.1600-0668.2005.00368.x
  7. United States Environment Protection Agency, "Radon Measurement in School" U.S. EPA, 1993.
  8. Ministry of Environment, "Indoor Air Quality Control In Public Use Facilities, etc. Act", pp. 36-38, 2004.
  9. M. Dovjak, A. Kukec, Z. Kristl, M. Kosir, M. Bilban, A. Krainer. "Integral Control of Health Hazards in Hospital Environment". Indoor and built Environment. Vol. 22, No. 5, pp. 776-795, 2013. https://doi.org/10.1177/1420326X12459867
  10. B. R. Lee, J. H Kim, K. S. Kim, H. J. Kim, K. Y. Lee, "Assessment of Thermal Comfort in a General Hospital in Winter Using Predicted Mean Vote (PMV)", J Environ Health sci. Vol. 41, No. 6, pp. 389-396, 2015.
  11. J. G. Kim, J. M. Park, "A Study on Design Method depending upon Low Carbon Green Architecture of Big Medical Center", Journal of the Korean Society of Civil Engineers, Vol. 35, No. 4, pp. 987-996, 2015. https://doi.org/10.12652/Ksce.2015.35.4.0987
  12. E. S. Chapin, "Human Activity Patterns in the City: Things People do in Time and in Space", John Wiley and Sons, New York, 1974.
  13. Ministry of Education, "School Environment, Health and Food Hygiene Manual", 2006.
  14. C. A. 3rd Pope, M. Ezzati, D. W. Dockery, "Fine-particulate Air Pollution and Life Expectancy in the United States", N Engl J Med, vol. 360, pp. 376-386, 2009. https://doi.org/10.1056/NEJMsa0805646
  15. Y. M. Jo, Y. C. Hong, "The Role of the Korean Medical Association Health Effects Caused by PM", Health policy forum, Vol. 12, No .2, pp. 32-36, 2014
  16. B. R. Seo, M. H. Jeong, J. M. Jeon, "Indoor Air Quality in Various Type of Public Facilities at Honam Province", Kor. J. Env. Hlth. Soc., Vol. 32, No. 5, pp. 387-397, 2006.
  17. Ministry of Environment, "A Study on Indoor Air Pollution Characterization and Management", 2002.
  18. J. B. Schoenberg, C. A. Mitchell, "Air-way Disease Caused by Phenolic(Phenol-Formaldehyde) Resin Exposure", Arch. Environ. Health, vol. 30, pp. 574-577, 1975. https://doi.org/10.1080/00039896.1975.10666782
  19. Y. H. Park, S. W. Kim, H. H. Yang, O. K. Chung, S. J. Lee, "Kids Cafe Indoor Air Quality Analysis Based on Furniture and Installation Facilities", Journal of the Korea Furniture Society, Vol. 24, No. 1, pp. 70-78, 2013.
  20. H. S. Jang, "A study on Measures at Indoor Air Quality Control of Home Daycare Center", J. Korean Soc. Living Environ. sys., Vol. 21, No. 5, pp. 698-705, 2014. https://doi.org/10.21086/ksles.2014.10.21.5.698
  21. J. R.l Sohn, Y. M. Roh, B. S. Son, "The Assessment of Survey on the Indoor Air Quality at Schools in Korea", Kor. J. Env. Hlth., Vol. 32, No. 2, pp. 140-148, 2006.
  22. I. H. Jung, "Airborne Asbestos Concentrations of Dental Laboratoties in One Metropolitan City", Journal of the Korea Convergence Society, Vol. 2, No. 1, pp. 31-36, 2011.