• Title/Summary/Keyword: 신호효과

Search Result 3,186, Processing Time 0.028 seconds

Uncertainties of SO2 Vertical Column Density Retrieval from Ground-based Hyper-spectral UV Sensor Based on Direct Sun Measurement Geometry (지상관측 기반 태양 직달광 관측장비의 초분광 자외센서로부터 이산화황 연직칼럼농도의 불확실성 분석 연구)

  • Kang, Hyeongwoo;Park, Junsung;Yang, Jiwon;Choi, Wonei;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.289-298
    • /
    • 2019
  • In this present study, the effects of Signal to Noise Ratio (SNR), Full Width Half Maximum (FWHM), Aerosol Optical Depth (AOD), $O_3$ Vertical Column Density ($O_3$ VCD), and Solar Zenith Angle (SZA) on the accuracy of sulfur dioxide Vertical Column Density ($SO_2$ VCD) retrieval have been quantified using the Differential Optical Absorption Spectroscopy (DOAS) method with the ground-based direct-sun synthetic radiances. The synthetic radiances produced based on the Beer-Lambert-Bouguer law without consideration of the diffuse effect. In the SNR condition of 650 (1300) with FWHM = 0.6 nm, AOD = 0.2, $O_3$ VCD = 300 DU, and $SZA=30^{\circ}$, the Absolute Percentage Difference (APD) between the true $SO_2$ VCD values and those retrieved ranges from 80% (28%) to 16% (5%) for the $SO_2$ VCD of $8.1{\times}10^{15}$ and $2.7{\times}10^{16}molecules\;cm^{-2}$, respectively. For an FWHM of 0.2 nm (1.0 nm) with the $SO_2$ VCD values equal to or greater than $2.7{\times}10^{16}molecules\;cm^{-2}$, the APD ranges from 6.4% (29%) to 6.2% (10%). Additionally, when FWHM, SZA, AOD, and $O_3$ VCD values increase, APDs tend to be large. On the other hand, SNR values increase, APDs are found to decrease. Eventually, it is revealed that the effects of FWHM and SZA on $SO_2$ VCD retrieval accuracy are larger than those of $O_3$ VCD and AOD. The SZA effects on the reduction of $SO_2$ VCD retrieval accuracy is found to be dominant over the that of FWHM for the condition of $SO_2$ VCD larger than $2.7{\times}10^{16}molecules\;cm^{-2}$.

Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS) (EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링)

  • Woo, Seong-Yeop;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.651-662
    • /
    • 2022
  • The electrochemical impedance spectroscopy(EIS) method was used to evaluate the concrete deterioration process related to chloride-induced steel corrosion with various corrosion levels(initiation, rust propagation and acceleration periods). The impressed current technique, with four total current levels of 0C, 13C, 65C and 130C, was used to accelerate steel corrosion in concrete cylinder samples with w/c ratio of 0.4, 0.5, and 0.6, immersed in a 0.5M NaCl solution. A series of EIS measurements was performed to monitor concrete deterioration during the accelerated corrosion test in this study. Some critical parameters of the equivalent circuit were obtained through the EIS analysis. It was observed that the charge transfer resistance(Rc) dropped sharply as the impressed current increased from 0C to 13C, indicating a value of approximately 10kΩcm2. However, the sensitivity of Rc significantly decreased when the impressed current was further increased from 13C to 130C after corrosion of steel had been initiated. Meanwhile, the double-layer capacitance value(Cdl) linearly increased from 50×10-6μF/cm2 to 250×10-6μF/cm2 as the impressed current in creased from 0C to 130C. The results in this study showed that monitoring Cdl is an effective measurement parameter for evaluating the progress of internal concrete damages(de-bonding between steel and concrete, micro-cracks, and surface-breaking cracks) induced by steel corrosion. The findings of this study provide a fundamental basis for developing an embedded sensor and signal interpretation method for monitoring concrete deterioration due to steel corrosion at various corrosion levels.

Protective Effects of Trifolium pratense L. Extract against H2O2-induced Oxidative Stress in HaCaT Keratinocytes (인간 피부각질세포에서 Hydrogen peroxide로 유도된 산화적 스트레스에 대한 붉은 토끼풀 추출물의 세포 보호 효과)

  • Mi Song Shin;You Kyeong Lee;Seo Young Choi;Ji Sun Hwang;Parkyong Song;Hyeon Cheal Park;Keun Ki Kim;Hong-Joo Son;Yu-Jin Kim;Kwang Min Lee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.223-232
    • /
    • 2023
  • Oxidative stress plays a significant role in the pathogenesis of various skin conditions, resulting in cellular and tissue damage that can contribute to the development of skin tone unevenness, roughness and wrinkles. In this study, we found that Trifolium pratense L. extract (TE) attenuated oxidative-induced damage in HaCaT cells and elucidated the underlying molecular mechanism. Our finding demonstrated that TE effectively protected HaCaT cells against H2O2-induced cell death by inhibiting caspase-3 activation, downregulating Bax and upregulating Bcl-2, and attenuating the activation of three mitogen-activated protein kinases (MAPKs). Our results suggest that TE has remarkable cytoprotective properties against oxidative damage in HaCaT cells and could serve as a complementary or alternative approach to prevent and treat skin damage.

Effects of vowel types and sentence positions in standard passage on auditory and cepstral and spectral measures in patients with voice disorders (모음 유형과 표준문단의 문장 위치가 음성장애 환자의 청지각적 및 켑스트럼 및 스펙트럼 분석에 미치는 효과)

  • Mi-Hyeon Choi;Seong Hee Choi
    • Phonetics and Speech Sciences
    • /
    • v.15 no.4
    • /
    • pp.81-90
    • /
    • 2023
  • Auditory perceptual assessment and acoustic analysis are commonly used in clinical practice for voice evaluation. This study aims to explore the effects of speech task context on auditory perceptual assessment and acoustic measures in patients with voice disorders. Sustained vowel phonations (/a/, /e/, /i/, /o/, /u/, /ɯ/, /ʌ/) and connected speech (a standardized paragraph 'kaeul' and nine sub-sentences) were obtained from a total of 22 patients with voice disorders. GRBAS ('G', 'R', 'B', 'A', 'S') and CAPE-V ('OS', 'R', 'B', 'S', 'P', 'L') auditory-perceptual assessment were evaluated by two certified speech language pathologists specializing in voice disorders using blind and random voice samples. Additionally, spectral and cepstral measures were analyzed using the analysis of dysphonia in speech and voice model (ADSV).When assessing voice quality with the GRBAS scale, it was not significantly affected by the vowel type except for 'B', while the 'OS', 'R' and 'B' in CAPE-V were affected by the vowel type (p<.05). In addition, measurements of CPP and L/H ratio were influenced by vowel types and sentence positions. CPP values in the standard paragraph showed significant negative correlations with all vowels, with the highest correlation observed for /e/ vowel (r=-.739). The CPP of the second sentence had the strongest correlation with all vowels. Depending on the speech stimulus, CAPE-V may have a greater impact on auditory-perceptual assessment than GRBAS, vowel types and sentence position with consonants influenced the 'B' scale, CPP, and L/H ratio. When using vowels in the voice assessment of patients with voice disorders, it would be beneficial to use not only /a/, but also the vowel /i/, which is acoustically highly correlated with 'breathy'. In addition, the /e/ vowel was highly correlated acoustically with the standardized passage and sub-sentences. Furthermore, given that most dysphonic signals are aperiodic, 2nd sentence of the 'kaeul' passage, which is the most acoustically correlated with all vowels, can be used with CPP. These results provide clinical evidence of the impact of speech tasks on auditory perceptual and acoustic measures, which may help to provide guidelines for voice evaluation in patients with voice disorders.

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.

The Role of c-Jun N-terminal Kinase in the Radiation-Induced Lung Fibrosis (방사선에 의한 폐 섬유화증에서 c-Jun N-terminal Kinase(JNK)의 역할)

  • Uh, Soo-Taek;Hong, Ki-Young;Lee, Young-Mok;Kim, Ki-Up;Kim, Do-Jin;Moon, Seung-Hyuk;Kim, Yong-Hoon;Park, Choon-Sik;Yeom, Uk;Kim, Eun-Suk;Choi, Doo-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.450-461
    • /
    • 2001
  • Background : The underlying pathogenesis of radiation-induced lung fibrosis (RTLF) has not been very well defined. However, the role of TGF-$\beta$ in the generation of RTLF has been a major focus because there is an increase in the expression of both the TGF-${\beta}m$-RNA and its protein preceding RTLF lesions. The down stream signal after a TGF-$\beta$ stimulated lung fibrosis includes the activation of many mediators such as Smad and c-Jun N-terminal kinase (JNK) through TAK1. It is we hypothesized that JNK activation may play a pivotal role in RTLF pathogenesis through increased transcription of the fibrogenic cytokines. The present study evaluates JNK activity in alveolar macrophages after irradiation and the relationship between JNK activity and the amount of collagen in the lung tissues. Methods : C57BL/6 mice(20-25 gr, males) received chlorotetracycline(2g/L) in their drinking water 1 week prior to irradiation and continuously there after. The mice were irradiated once with 1400 cGy of $60CO{\gamma}$-ray over the whole chest. The cellular composition of the whole lung bronchoalveoalr lavage fluids(BALF), elastin expression in the lung tissues, the level of hydroxyproline in lung tissues, and an in vitro JNK assay was measured before irradiation and one, four, and eight weeks after irradiation (RT). Results : The volumes of BALF retrieved from instilled 4 mL of saline with 2% heparin were 3.7-3.8 mL for each group. The cell numbers were similar before($4.1{\times}10^4{\pm}0.5{\times}10^4/mL$) and 1 week($3.1{\times}10^4{\pm}0.5{\times}10^4/mL$) after RT. At four and eight weeks after RT, the cell number reached to $14.0{\times}10^4{\pm}1.5{\times}10^4mL$ and $10.0{\times}10^4{\pm}1.3{\times}10^4/mL$, respectively. There we no changes in the lymphocytes and neutrophils population observed in the BALF after RT. The H-E stain of the lung tissues did not show any structural and fibrotic change in the lung tissues at 4 and 8 weeks after RT. In addition, the amount of elastin and collagen were not different on Verhoeff staining of the lung tissues before RT to eight weeks after RT. The hydroxyproine content was measured with the left lung dissected from the left main bronchus. The lung were homogenized and hydrolyzed with 6 N Hel for 12 hours at $110^{\circ}C$ then measured as previously described. The content of hydroxyproline, standardized with a lung protein concentration, reached a peak 4 weeks after RT, and thereafter showed a plateau. AnIn vitro JNK assay using c-$Jun_{1-79}$-GST sepharose beads were performed with the alveolar macrophages obtained from the BAL. JNK activity was not detected prior to RT, However, the JNK activity increased from one week after RT and reached a peak four weeks after RT. Conclusion : JNK may be involved in the pathogenesis because the JNK activity showed similar pattern observed with the hydroxyproine content. However, it is necessary to clarify that the JNK increases the transcription of fibrogenic cyiokines through the transcription factor.

  • PDF

The Effect of Iron Content on the Atomic Structure of Alkali Silicate Glasses using Solid-state NMR Spectroscopy (비정질 알칼리 규산염 원자구조의 철 함량 효과에 관한 고체 NMR 분광학 연구)

  • Kim, Hyo-Im;Lee, Sung-Keun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.301-312
    • /
    • 2011
  • The study on the atomic structure of iron-bearing silicate glasses has significant geological implications for both diverse igneous processes on Earth surface and ultra-low velocity zones at the core-mantle boundary. Here, we report experimental results on the effect of iron content on the atomic structure in iron-bearing alkali silicate glasses ($Na_2O-Fe_2O_3-SiO_2$ glasses, up to 16.07 wt% $Fe_2O_3$) using $^{29}Si$ and $^{17}O$ solid-state NMR spectroscopy. $^{29}Si$ spin-lattice ($T_1$) relaxation time for the glasses decreases with increasing iron content due to an enhanced interaction between nuclear spin and unpaired electron in iron. $^{29}Si$ MAS NMR spectra for the glasses show a decrease in signal intensity and an increase in peak width with increasing iron content. However, the heterogeneous peak broa-dening in $^{29}Si$ MAS NMR spectra suggests the heterogeneous distribution of $Q^n$ species around iron in iron-bearing silicate glasses. While nonbridging oxygen ($Na-O-Si$) and bridging oxygen (Si-O-Si) peaks are partially resolved in $^{17}O$ MAS NMR spectrum for iron-free silicate glass, it is difficult to distinguish the oxygen clusters in iron-bearing silicate glass. The Lorentzian peak shape for $^{29}Si$ and $^{17}O$ MAS NMR spectra may reflect life-time broadening due to spin-electron interaction. These results demonstrate that solid-state NMR can be an effective probe of the detailed structure in iron-bearing silicate glasses.

What are the Possible Roles of CO2 on Stomatal Mechanism? (기공 메커니즘에 대한 CO2의 역할은 무엇인가?)

  • Lee, Joon Sang
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.1
    • /
    • pp.130-134
    • /
    • 2016
  • How does $CO_2$ affect on the stomatal mechanism? The mechanism of stomatal opening by $CO_2$ is not clear as it is difficult to see $CO_2$ effect on light-induced stomatal opening. Furthermore, stomata may react differently according to the concentration of $CO_2$. The significance of the possible endogenous rhythms must consider to understand on $CO_2$-related response. It is clear that $CO_2$ has an effect on the accumulation of osmotic materials which determines the degree of stomatal apertures because it is known that stomata open in the condition of the reduced $CO_2$ concentration. However, it is not fully understood how $CO_2$ leads to the stomatal opening. It has been thought that $CO_2$ can not affect on the ion fluxes which determines the increase of osmotic potential in guard cells. However, in this study, the changes of guard cell membrane permeability by $CO_2$ have been focused on. There are many reports that $CO_2$ related reactions are dominant when the leaf is exposed to certain a mount of $CO_2$. The hypothesis of the stomatal opening by light is based on the increase of osmotic materials in guard cells including $K^+$, $Cl^-$, sucrose and $malate^{2-}$. It was reported that $CO_2$ induced a big hyperpolarization indicating that $H^+$ was extruded to the cell outside. It was also found that $CO_2$ caused guard cell membrane hyperpolarization in the intact leaf up to 3 or 4 times higher than that of light induced membrane hyperpolarization. These results represent that $CO_2$ can affect on the change of physical characteristics which affects on the change of the membrane permeability.

Forsythiae Fructus Induces VEGF Production via p38 MAPK Activation in Human Keratinocytes (각질형성세포에서 p38 MAPK 활성을 통한 연교의 VEGF 생성 효과)

  • Kim, Mi-Sun;Choi, Yun Ho;Park, Sun Gyoo;Lee, Cheon Koo;Lee, Sang Hwa
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.4
    • /
    • pp.329-336
    • /
    • 2016
  • Cutaneous microvasculature plays a critical role in age-associated skin changes. A considerable reduction of number and size of vessels has been observed in the upper dermis of elderly skin. Forsythiae fructus (FF), the dried fruit of plant Forsythia suspensa (F. suspensa), has been traditionally used as an herbal medicine to treat inflammatory diseases and bacterial diseases. However, its regulatory effect on angiogenic responses has not been elucidated in skin. Therefore, we analyzed secretory profiles upon treatment of FF extract using array designed to detect angiogenesis-associated mediators in human keratinocytes. Because keratinocyte-derived VEGF (vascular endothelial growth factor) has been regarded as a potent factor for new microvasculature under the epidermis, we further investigated the effect of FF extract on VEGF production. We observed that the VEGF expression of mRNA and protein level was increased by about 2 folds in a dose-dependent manner after FF extract treatment. In signaling experiments, FF extract induced rapid p38 MAPK activation within 5 min, and the activation was totally abrogated by pretreatment with a p38 MAPK specific inhibitor. The FF-induced VEGF upregulation was also significantly attenuated by a p38 MAPK inhibition. Taken together, FF extract induces VEGF production via p38 MAPK activation in human epidermal keratinocytes. These novel findings suggest that FF is useful as a potential agent with pro-angiogenic activity and may help to improve age-dependent reduction of the microvasculature in aged skin or to heal skin wound.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).